Flashes & lighting
Acute 12 / 24 Flash Unit User manual
User manual for Acute 12 / 24 Flash Unit. 15 pages. Read the original PDF, download or print a copy without registration.
15 pagesOriginal document1.3 MB PDF

Loading your manual…Open PDF directly
Document details
- Brand
- Acute
- Model / document
- Acute 12 / 24 Flash Unit
- Document type
- User manual
- Language
- Check the original document
- Pages
- 15
- File size
- 1.3 MB
- Category
- Flashes & lighting
- Document date
- Not specified in catalog
Search available document text
Find a term, then jump to its page in the original PDF. Image-only pages may not be searchable; check the PDF for exact wording and diagrams.
Page 4 · Read text
CONTENTS Nomenclaturegenerator. . Nomenclatureflashheads ..... .5 Briefmanual ....6 Voltageselection .....6 Mains(AC)connection. ....6 Charging... ......7 Modellinglamp .......7 Thereadylamp/TestButton. . . . . . . . . .7 Synchronisation ......8 Photocell .......8 Acousticsignal .......8 Recyclingtimeadjustment. .....8 Flashheads .....9 Flashtube Colourtemperature . . .10 EnergyDistribution. ..11 Energycontroland"Bracketing".....12 Automaticsafetyfunction. r i.. ..13 Warranty.. ......13 Technicaldata ...14View original page 4
Page 5 · Read text
NOMENCLATU R E, G EN ERATOR Recyclingswitch Recyclingtime adjustment Energyswitch(groupA) Modellinglightswitch Voltageselector Isolate/Comb ine switch Acousticsignalswitch Energyswitch(groupB) Readylamp/test Syncinput Photocell Energycontrol"Bracketing" Flashheadconnection(groupA) Mainsconnection Flashheadconnection(groupB)View original page 5
Page 6 · Read text
NOMENCLATURE FLASHH EADS
Acute (PA)flash head
Flashtube
Modellinglamp100WE27
Umbrellareceptacle
Acute (AB) flash head (fan cooled)
Voltageselector(forfan)
Manoeuvresystemwith lockinglever
Standadapter16mm(5/8")
Frostedglasscover
HalogenmodellinglamP150WE27
GlassretainercliPView original page 6Page 7 · Read text
BRIEFMANUAL
Checkthatthe voltageselector,on generatorand flashhead,
is compatiblewiththe mainssupplyvoltage
o Checkthatthe modellinglamphasthe correctvoltage
o Connectflashhead/s
o Connectthe mainssupplycable
o Chooserecyclingtime
o Switchon charging(FLASHON)
o Switchon modellinglight(MODON)
o Chooseenergydistribution
o Pressthe readylamp/testbuttonfor f lash
o Connectsynccable
VOLTAGESELECTION
Thereare two voltagerangesto choose
between:90-130V60Hzor 180-260V50Hz
Beforemainsconnectionmakesurethatthe
voltageselectormatchesthe mainssupply
voltageon generatorand flashheads.
Checkalsothatthe modellinglamphasthe
correctvoltage.
MAINS(AC)CONNECTTON
The generatoris designedforAC connection
only.lt can be connectedto the mostcommon
mainsvoltages:90-130V60Hzor 180-260V
50H2.Beforemainsconnectionmakequrethat
the voltageselectorsmatchthe mainssupply
voltage.
Connectthe unitto the mainswiththe cable
includedin the delivery.
WARNING!
Never use ordinary household extensioncords
to extendthe power cable.Theymay overheat.
Contactyour Profoto distributorfor proper
equipment.View original page 7Page 8 · Read text
CHARGING
Checkthat the voltageselectorsmatchthe
mainssupplyvoltage.Turnon the mainswitch
(FLASHON).
The recyclingtime is very short.Variationswill
occurdependingon the selectedflashenergy
and voltage.Theshortestrecyclingtime is
obtainedwith lowflashenergy
MODELLINGLAMP
The modellinglampcan be turnedon/offby the
switchon generator(MODON).In the off posi-
tionthe fan,in the flashhead,is alsoturnedoff.
The modellinglampis powereddirectlyfromthe
mains.lt is thereforeimportantto checkthatthe
ratedvoltagefor the lampcorrespondswiththe
mainssupply.A100Wattmediumscrewbase
lamp(E27)is includedin standarddeliveries.
The AB flashheadcan also be fittedwith a
Halogen150-250Wattmediumscrewbase
lamp(E27).
Theflashtubeand the modellinglampcan be
enclosedin a f rostedglasscoverfor a closer
matchingof modellinglightandflashillumi-
nation.
NOTE!
ALWAYSIJNPLLJGTHELAMP CABLE FROM
THE GENERATORBEFORE CHANGING
MODELLINGLAMP OR FLASHTUBE.
READYLAMP/TESTBUTTON
The readyl"Tp buttonhastwo functions.First,it
lightsup whenthe unitis fullyrecycled.Second,
it can be used'tomanuallysyncthe unit(open
f lash).Whena lowerenergysettingis chosen,
withthe "Bracketing"selector,releasea flashso
thatthe unitcan recycleforthe newenergy
settingView original page 8Page 9 · Read text
SYNCHRONIZATION
Synchroniseby connectingthe synchrocable
f romthe camerato the synchroinput.when the
synchrocableis connectedthe built-inphotocell
willbe disabled.
PHOTOCELL
The photocellon the generatorpanelservesas a
slavesyncwhenanotherflashappears.Whena
synchrocableis usedthe photocellis automati-
callydisabled
ACOUSTICSIGNAL
The unitsacousticsignalsystem"beeps"when
the unithasfullyrecy'cled.lf the signalisn't
wanted,pressthe buttonmarked"sound".
RECYCLINGTIME ADJ USTMENT
with the recyclingadjustmentdialthe recycling
timecan be lengthenedgraduallyto help
preserveweakfusesor heavilyloadedmains
supply.View original page 9Page 10 · Read text
FLASHHEADS Acute(AB and ABS)flashhead The AB/ABSflashheadis fan-cooled.Make surethatthe voltageselectormatchesthe mains supplyvoltage.Checkalsothatthe modelling lamphas the correctvoltage. The AB flashheadis deliveredwiththe Disc reflectorintendedfor usewithan umbrella. When moreadvancedlightingis desired,we recommendthe use of any of Profotosmany accessoriesand reflectorsall easilyattached directlyontothe head. The PAflashheadis convection-cooled,i.e. withoutfancooling,whichputsa limiton the numberof flashesthatthe lampheadcan emit withoutoverheating.Themaximumoutputis 4800Wsper minutewhichis to a2400Wsflash every30 secondsor 1200Wsflashevery15 seconds,or 600Wsflashevery8 seconds,or 300Wsevery4 seconds,and so on. The modellinglampincludedin the deliveryis a 100Wattmediumscrewbaselamp(E27).The AB headcan alsobe fittedwitha Halogen150- zSOWattmediumscrewbaselamp(E27).The flashtubeandthe modellinglampcan be enclosedin a f rostedglasscoverfor a closer matchingof modellinglightandflash illumination. The ABS flashheadis deliveredwiththe Zoom reflector,Halogenmodellinglampl50Wattand frostedglasscover.View original page 10
Page 11 · Read text
FLASHTUBE
A UV-coatedQuartzflashtube is includedin
standardPAand AB/ABSflashheaddeliveries.
The flashtubehastwo metalpinsfor insertion
intothe unit.When removinga flashtube,pullit
straightout of the sockets.When insertinga flash
tube,checkthatthe trigger-wireconnection
claspsproperlyaroundthe flashtube.
NOTE!
ALWAYSUNPLUGTHELAMP CABLEFROM
THE GEN ERATORBEFORE CHANGING
MODELLINGLAMP OR FLASHTUBE.
COLOURTEMPERATURE
A f rostedglasscoveris includedin AB Special
(ABS)flashheaddeliveries.lt gives,
in combinationwiththe UV-coatedflashtube,
a recommendedcolourtemperaturefordaylight
typefilm. a
Distinctivecolour temperature adjustmentscan
be obtainedby combiningflashtubesand/or
glasscoverswithdifferentcoatings.
1 0View original page 11Page 13 · Read text
a
ENERGYCONTROL
Withthe "bracketing"selectorthetotalenergy
can,irrespectiveof the energydistribution,be
reducedby 50%(1/1 to 112 -one f/stop)in 114ot
one f/stop.
''BRACKETING''
Turnthe "bracketing"selectortothe middledot.
Findthe rightf/stopwiththe flashmeter.Make
the firstexposure.
Turnthe selectorto1/1energy.TheLightpower
increasesto a 1 12stopoverexposure.Makethe
secondexposure.
Turnthe selectorto112energy.Pressthe test
button.Afterrecyclingthe lightpoweris
decreasedto a 112'flstopunderexposure.
Now makethe thirdexposure.
This resultsin threedifferentexposures.One is
"correct",one is overexposedby a1l2flstopand
one is underexposedbya1l2flstop.Therehave
beenthreedifferentexposureswithoutany
changein lightingor depthof f ield.
lt is of coursepossibleto chooseonlya ll4tlstop
"bracketing".111energyto 112energyis one
f/stopand betweendots is a 114ot onef/stop.
1 2View original page 13Page 14 · Read text
t
AUTOMATICSAFETYFUNCTION
Thefirstchargingcycle,afterthemainsswitch
has beenturnedon, is alwaysin a slowstep
mode (opencharging)to allowthe statusof the
capacitorsto be gauged.lf the capacitorshave
developedhighleakagecurrent,whichhappens
if the flashunithas not beenusedfor a while,the
chargingwillbe aborted.lfthisoccurs,turnthe
chargingoff,setthe "BRACKET"to 112and wait
about30 secondsbeforeturningit on again.
Repeatthisa fewtimes,and increasethe#
t charged,"BRACKET"takesetting.the unitlftothequalifiedgeneratorrepairstillisn'tfully
personnelfor service.
lf the unitis underintensiveusewithfrequent
flashingfora longperiodof time,the recycling
willstopcompletely.Thisis to preventthe unit
fromoverheating.
WARRANTY
All Profotoproductsare guaranteedfora period
of 2 years,with the exceptionof flashtubes and
modellinglamps.
I
. *
13
.-"^l**--; .;: -;*i :,r.-. ,^d{fgeLl$ .,;**,-s*&gd;&i1ffi '.View original page 14From the M. Butkus archive. Original publisher and archive notices are retained.
Check the model and edition against your equipment.
PDF verified 2026-10-10.