Camera accessories
ESSENKAY Color Film Adapter Product booklet
Product booklet for ESSENKAY Color Film Adapter. 10 pages in English. Read the original PDF, download or print a copy without registration.
10 pagesEnglish1.1 MB PDF

Loading your manual…Open PDF directly
Document details
- Brand
- Essenkay
- Model / document
- ESSENKAY Color Film Adapter
- Document type
- Product booklet
- Language
- English
- Pages
- 10
- File size
- 1.1 MB
- Category
- Camera accessories
- Document date
- Not specified in catalog
Search available document text
Find a term, then jump to its page in the original PDF. Image-only pages may not be searchable; check the PDF for exact wording and diagrams.
Page 1 · Read text
INSTRUCTIONS
kd
ESS E N KAY
Color Film Adopters
Iot
Roll Film Comeros
Sole Distributors
BURKE t, JAMES, Inc.
Chicogo, lllinois . U. S.A.
Printed ln U.S.A.View original page 1Page 2 · Read text
Directions for Using the Essenkay Color Fil es The new Essenkoy Adopter for the Duo Six-20 cqmerc contains lour spool exten- sions (two long ploin, one slotted short; qnd one ploin short), ct plastic viewing mqsk for the view-finder, q metql expo- sure-Ircme reducing mcsk, q counting diql, qnd c tckeup spool. Remove the screw Irom the center of the film-winding knob oI your cqmerc with cr smcll screw-driver, plcce the blqck count- ing dial over the knob qnd replcce the screw. (Thls counting dicl moy be lelt on the ccmerq permcrnently qs it will not in- terfere with normcl opercrtion.) Now open the cqmercr and plcce it fcce down. Put the slotted spool extension in one end of the tokeup spool, qnd one of the longer ploin spool extensions in the opposite end and instqll in the ccImercr, moking certqin thqt the slotted spool end is litted in the Ilcnge of the film-winding knob. Now, holding cr roll of 828 film qs it would normclly go into the ccrmercr, plcce the short spool extension in the end of the Iilm spool which will be ot the top oI the cqmerq, ond the remcining longer spool extension in the opposite end of the,spool. t Plqce this unit in the ccmerq. The metol t exposure-Ircme reducing mqsk should now be ploced in the exposure chomber so thqt I the bent ears of the mqsk fqce towards the front of the cqmerq. Center it so thct ItView original page 2
Page 3 · Read text
(
Film Adapler in tle Kodak Duo Six:20 u
it fits into the recess of the ccrmerd. Now, I!ft
with the cqmercr still lying lqce down,
bring the pcper leqder of the lilm qcross
the exposure frqme crnd qttcrch to the tqke-
up spool iust os you would with 120 size
Iilm.
Wind fust enough so the nqme oI the
lilm (Plus X, Panqtomic X, Kodachrome,
etc.) is qcross the spool. Now close the
ccmerc qnd give the film-winding knob
seven complete turns. The liist exposure
is now recdy. Open the ccrmercr view-
Iinder and place the plcstic viewing mqsk
inside the front pcrt of the viewer, press-
ing it lirmly in ploce. Expose crs you
would for I20 lilm, but do not Lrse the
exposure counting windows. Insteqd, ob-
serve the relctive position oI number one
on ihe counting diql which you mounted
on t-he film-winding knob. One complete
turn qnd post until number two is in the
sqnre relqtive position qs number one hqd
been will bring up the second exposure.
This sqme procedure should be lollowed
on through exposure number seven. For
exposures eight, nine qnd ten, wind qlmost
a complete turn untrl the desired number
is in the scme relqtive position qs the
one previous. With cqre, ten exposures
ccn be obtqined on block-qnd-white film,
qnd nine with color lilm.View original page 3Page 5 · Read text
Digitally signed by Mike Butkus
DN: cn=Mike Butkus, o=Butkus camera
manuals, ou=butkus.org, email=mike@butkus.
c=US Mike Butkus org,Date: 2021.04.17 17:55:19 -04'00' AUTO}f.ITI(; NOLT,RIFLEX,
es The new Essenkay Adapter for the
Automatic Rolleiflex camera contains
four spool extensions (two plain, one
slotted and one knurled), a plastic
mask for the ground glass viewing
screen, a metal exposure frame re-
ducing mask, and a takeup spool.
To use, open the camera and place
the metal exposure reducing mask in
the exposure chamber. Now place the
two plain spool extensions in an 828
size roll of film and install in the
rramera. Place the knurled extension
and the slotted exterrsion in opposite
encls of the takeup spool. The takeup
spoo! should then be placed in the
camela so that the slotted extension
fits in the flange on the film winding
knob, and the knurled extension is in
contact with the counting mechanism.
Push the knurled extension down
against the iilm counting mechanism
so that the spool may be fastened in
place by means- of the spring button
on the side of the camera. Now bring
the paper leader between the rollers
as usual, and fasten to the takeupView original page 5Page 6 · Read text
spool. Close the back of the eamera
but do not move the tension slide into
place. Wind until number 3 is on the
counting dial (shutter will have to be
tripped twice) and slide the tension
slide into place. The first exposure is
now in place. Place the plastic mask
over the ground glass viewing screen,
with the narrow end to the back of
the camera. Expose as you would
with 120 film. 8 exposures may be
secured on 828 film, and numbers on
the indicating dial will run from B to
10 inclusive. After exposing number
10 on your counting dial, wind the
paper trailer on the takeup spool and
remove exposed film from camera.
ROLLDIOORID and ROLLEIFLIIX
n The new Essenkay Adapter for these cameras contains four spool exten-
sions (two plain, one slotted and one
knurled), a plastic lnask for the
ground glass viewing screen, a metal
Sl exposure frame reducing mask, and a
takeup spool.
; To use, open the camera and place the metal exposure reducing mask inView original page 6Page 7 · Read text
the exposure chamber. Now place thees two plain spool extensions in an 828
size roll of film and install in the
camera. Place the knurled extension
and the slotted extension in opposite
ends of the takeup spool. The takeup,
spool should th6n be placed in the
camera so that the slotted extension
fits in the flange on the film winding
knob, and the knurled extension is in
contact with the counting mechanism.
Push the knurled extension down
against the counting mechanism so
that the spool may be fastened in
place by means of the spring button
on the side of the camera. (Note:
Early models of the Rolleicord do not
have the internal counting mecha-
nism, so references to it may be dis-
regarded.) Now secure the paper
leader of the film to the takeup spool.
winding just enough so that the name
of the film is across the spool. Clgse tl ihe back and wind until .trr-b". i it
on the counting dial. The first expo-
sure is nciw in place, so release the
counting mechanism and the dial will
drop back to number one. Place theView original page 7Page 8 · Read text
plastic mask over the ground glass
viewing screen, with the narrow end
to the back of the camera. Expose the
and stop automatic the film usrng t)' same counter with as you would the t<
120 film, stopping at number B which
is the last exposure. The paper trailer
may then be wound on the takeup
spool as usual, and the exposed film
remnved from the camera.
Nnw STANDAnD ROLLEIf'r.tlx
The new Essenkay Adapter for the
Standard Rolleiflex cattera contains
7 four spool extensions (two plain, one/ slotted and one knurled), a plastic
mask for the grqund glass viewing
scfeen, a metal exposure frame re-
ducing mask, and a takeup sPool.
To use, open the camera and Place
the m-etal exposure reCucing mask in
the exposure charrrbcr Now place the
two platn spool extensions in an 828
size roll of film and install in the
cameia. Place the knurled extension
and the slotted extension in opposite
ends of the takeup spool. The takeup
spEol should then be placed in the
camera so that the slotted extension
fits rrr the frange of the fiim win<iing
knob. and the knurled extension is
in contact with the counting mecha-
nism. Now bring the paper leader of
the film up and secure it on the take-
up spool, winding on iust enough so
that the name of the film is across the
spool. Close the camera and move the
slide into place. Give the film wind-
ing crank three and one-half com-
plete turns, and the usual "half back"
to cock the shutter. Number one is
now ready for exposure. Place the
plastic mask over the gtound glass
viewing screen, with the narrow end
to the back of the camera. After first
exposure the automatic fiIm stop and
counter will work as it does with 120
size film. Make eight exposures, then
go by the last fous (tripping the shut-
ter) and unload ih the usual manner.
SUPD|| TKONTA lt nnd RX
The new Essenkay Adapter for
these cameras contains four spool
extensions (three plain and one slot-
ted,), a metal exposure reducing
mask, a takeup spool, and a small
viewing mask. (Note: Viewing masks
are different for the single and doubleView original page 8Page 9 · Read text
window rirodels of the Super B. Make
certain your adapter unit contains
the correct mask for your camera.)
Turn dial to number one without
engaging automatic loek. Slide the
viewing mask over the view finder
window. Open the camera and place
the exposure reducing mask into the
expo:ure chamber. Now place two
of thc plain spool extensions in an
828 size roll of fiIm and install in the
camera. Place the slotted extension
and the remaining plain extension in
opposite ends of the takeup spool.
The takeup spool should be placed in
the camera so that the slotted exten-
sion fits in the flange of the film
winding knob. Now secure the paper
leader of the film to the takeup spool
and close the camera.
With the Super B, wind film until
counting dial is at number 6. (If care
is taken in turning winding dial so
lock does not spring, the winding of
the film to number 6 can be done in
one continuous operation.) The first
exposure is now ready, so set dial
back to number one and operate the
same as with 120 size film.
With the Super BX, set the red sig-
nal and wind through number one
(shutter must be tripped) to number
2. Expose numbers 2 to 9 inclusive,
then continue to wind (shutter must
be tripped on 10, 1,1 and 12) until all
paper is on takeup spool. Remove
exposed film as usual.
IIONE1LE NDFLEX. II(OFLBX II
and IKOFLEX III
The new Essenkay Adapter for
these cameras contains four spool ex-
tensions (three plain and one slot-
ted), a metal exposure reducing
mask, a plastic viewing mask for the
ground glass viewing screen, and a
takeup spool.
To use, place the exposure reduc-
ing mask in the exposure chamber
(it is advisable to tape the mask for
the Korelle Reflex in place by plac-
ing a piece of scotch tape straight
across the mask at the notches and
at right angles to the film track.)
Place two oI the plain spool exten-
sions in an 828 size roll of film and
install in the camera. Now place the
slotted extension and the remaining
plain extension in opposite ends ofView original page 9Page 10 · Read text
5
the takeup spool. The takeup spool
should then be placed in the camera
so that the slotted extension fits in
the flange of the film winding knob.
Connect paper leader from film to the
takeup spool and close camera.
The Korelle Reflex and late model
Ikoflex II should be wound to num-
ber ? on the exposure counting dial,
when the first exposure will be in
place. Now return the counting dial
to number one. Place viewing mask
over ground glass so that longer sides
of frame are parallel with film travel,
expose nine shots, and unload camera
as usual. (Note: The older model
Ikoflex II, with friction counting de-
vice, requires installation of a film
window in the back of the camera.)
The Ikoflex III cameras should be
wound to number 3, when the first
exposure. is in place. The counting
dial cannot be returned to number
one unless the back is opened, so
the exposures on 828 film will show
as numbels 3 to 10 inclusive, when
the film is removed in the usual
manner.
ANGOFT,EX. ALTIFI,EX.
IITOFI,EX T. WINGINtr'LEX,
tr|ABVEL.I'LEX. EXAI(TA B
and Sfunllar Carneras rvlth
Countln€ S'lndours
The new Essenkay Adapters for
these cameras contain four spool ex-
tensions (three plain and one slotted),
a mask for the viewing screen; a
metal exposure frame reducing mask,
and a takeup spool.
To use, open the camera and place
the metal exposure reducing mask in
the exposure chamber. Now place
two of the plain spool extcnsions in
an 828 size roll of film and install in
the camera. Piace the slotted exten-
sion and the remaining plaln exten-
sion in opposite ends of the takeup
spool. The takeup spool should then
be placed in the camera so that the
slotted extension fits in the fiange on
the film winding knob. No'*r secure
the paper leader of the film. to the
takeup spool and close the camera.
Wind until number 1 appears in the
window. Place mask over the view-
ing glass so that the picture is framed.
Film is advanced by watching the
number appear in the film window
while winding, just as with 120 size.View original page 10From the M. Butkus archive. Original publisher and archive notices are retained.
Check the model and edition against your equipment.
PDF verified 2026-10-10.