Page 2 · Read text
Contents Page
General introduction 1
Attaching 3
Technical information 4
Reflected light measurement 5
Ground glass measurements 6
Exposure measurement in general 6
Exposure measurement with twinlens reflex cameras I
Exposure measurement on reflex cameras with
fully automatic diagrams 9
When measurement is not possible with working aperture I
Determination of individual reading index 10
with grey card 10
with test photos 10
Contrast measurement 13
Subject contrast 13
lllumination contrast 13
Density measurement 13
Luminance measurement 14
Measurement of illumination intensity 15View original page 2Page 3 · Read text
General introduction This MEASURING PROBE attachment converts your system exposure meters LUNA- SIX F, LUNASIX 3 or LUNALITE for operations which are not feasible with an ordinary meter. Together with the MEASURING PROBE attachment the extreme sensitivity of the system exposure meter is utilized fully. For each subject, where exposure of very narrow and inaccessible spots has to be measured, the flexible MEASURING PROBE with its small measuring aperture will be of great assistance. The MEASURING PROBE is especially suitable for exposure measurement in macrography, ground glass measurement, in microphotography, for density mea- surement on negatives or transparencies and for luminous density measurement. Even contrast measurement (density contrast, subject etc.) can easily be assessed. Note: Before reading the following detailed instructions, you should be completely familiar with the general operating procedures outlined in the manual of your system exposure meter.View original page 3
Page 5 · Read text
Attaching to thd system exposure meter
Fitting the MEASURING PROBE is very easy:
Shift the diffusing sphere so that it fits into the
key of the attachment, and engage meter and
the attachment while pressing button. Aft,er
depressing the button, the system exposure
meter and MEASURING PROBE are firmly
connected.
Set the film speed according to the instructions
for use for the system exposure meter.
Digitally signed by Mike ButkusMike DN: cn=Mike Butkus, o=Butkus
camera manuals, ou=butkus.org,
email=mike@butkus.org, c=USButkus Date: 2020.09.30 19:38:29 -04'00'View original page 5Page 6 · Read text
Technical information
Only the finest materials are used
in your MEASURING PROBE. How-
ever, the fibers in the probe can
be damaged if subjected to abuse.
Breakage of the fibers will cause
loss of efficiency, affecting the ca-
libration of the probe. Reasonable
care should be exercised when
using the MEASURING PROBE. Do
not subject it to abnormal stress,
bend it at very sharp angles, or
allow objects to strike or rest on
the probe.
The MEASURING PROBE consists
of approximately 4,000 glass fibers
of around 0.07 millimeters diameter
each.
Length 400 mm
Measuring aperture
5 mm diameter
equal to approxi-
mately 19.6 mm2
Difference in exposure values be-
tween the attachment and the meter
itself at 21 DIN/100 ASA Angle sensitivity of MEASURING PROBE
+4LUNASIXF+2 LUNASIX3-3 LUNALITEMeasuring angle approx. 30oView original page 6Page 7 · Read text
Reflected light measurement The MEASURING PROBE is particularly suitable for macrophotography, for close measurement of small areas and for detail measurements of small subjects which are usually inaccessible with an exposure meter, e. g. scaled down copies of interiors or landscapes, details of architectural models, circuit designs, etc. Direct the measuring aperture of the MEASURING PROBE towards your subject taking care that you or the meter do not create a shadow. More reliable results will be obtained by using a grey-card. For this purpose place a small mid-grey card in front of the important part of the subject and direct the measuring aperture against the grey-card without shadowing it. When taking the measurement ensure that only the area of the grey-card is read, if the distance is too great the adjacent surrounding could falsify the reading. * You measure then in the usual way: LUNASIX F and LUNALITE: First set the white index line for EV modification (15) on the green scale (13) to "+3" in orderto compensate the loss of light due to the PROBE. Press the red measuring button (6). After releasing the button, the value measured at that moment will be stored automatically in the electronic memory of your system exposure meter. Next turn the computer ring (24) until the indicator needle is precisely at "0" or the central LED (38) will light up. Read the shutter speed and f/stop combinations suitable for your subject on the scales 17 and 18. * The distance between grey-card and measuring aperture must not be greater than the diameter of the largest circle which you could draw on the grey-card.View original page 7
Page 8 · Read text
LUNASIX 3:
higherSetect on the LUNASIX 3 a DIN/ASA exposure index which is 9 digits
than the one suggested by the film manufacturers, e.g. take 27 DIN/ASA instead
of 18 DlNi50 ASA. The scale value indicated is set as usual at the yellow triangular
index and you can now read the tlme-aperture values suitable for your subject to
be measured at the upper end of the LUNASIX 3 calculator ring.
Ground glass measurements
Exposure measurement in general
The MEASURING PROBE is ideal for ground glass measurements. All variations
such as filter factors, factor for bellow extension, and stray light are compensated
for.
The measuring aperture of the MEASURING PROBE is put in contact with relevant
area of the ground glass. External light must be eliminated by means of a black
cloth. lt is advisable not to measure at the corners of the ground glass as a decrease
aof light can be registered, which is essentially a feature of the lens. By using
fresnel lens this effect can be largely overcome.
To determine the exposure time it is expedient to use a grey-card which should
be placed in such a way, that it receives the same illumination as the important
part of the picture to be measured. You then take measurei"nents ol the image of
the grey card.
LUNASIX F and LUNALITE:
You press down the red button (6), and the value measured at that moment will be
automatically stored in the electronic memory of the meter, when you release the
6View original page 8Page 9 · Read text
button. You then rotate the computer ring (24) until the indicator needle (4) points
exactly at the "0" on the scale or the central LED (38) will light up. On ihe'scale
(17) you now read the exposure time which is opposite t/1 on the aperture scale (18).
f/1 is your reading index for this measurernent with your chosen working aperture.
Extension factors due to bellows or filters used are automatically compensated for.
LUNASIX 3:
The film sensitivity is set 9 digits higher as described on page B. Set the indicated
scale value on the green mark of your LUNASIX 3 and read the exposure time at
f/2'8' ln this case the aperture index f/2.8 stands for the reading index and has
nothing to do with the aperture set at the lens.
www.butkus.us
lf no time value is opposite of the reading index, set the next shutter speed to
it and then read the figure opposite of the green symbol. Then close or open
the lens aperture until the needle moves to that figure on the scale.View original page 9Page 10 · Read text
@@@
@@@
www.butkus.us
O Measuring spots for ground glass measurementView original page 10Page 11 · Read text
Exposure measurement with twin lens reflex cameras
The viewing lenses of twin lens reflex cameras are not provided with diaphragms'
The relative aperture of the viewing lens is usually the same as the maximum
aperture of the taking lens. Thus ybu can practically use the reading index for
I maximum aperture as described. For a smaller working aperture the computer
ring (24) of the LUNASIX F and LUNALITE or (7) of LUNASIX 3 should be used.
Rolatb ine computer ring to set the exposure time which was indicated now I opposite the f/siop on scale which equals your viewing lens aperture. Then read
eiiosure time and f/stop for your taking lens on the scales as usual.
Exposure measurement on reflex cameras with fully automatic diagrams
Set the required working aperture manually and then take the reading.
When measurement not possible with working aperture
This may occur with smaller apertures or where filters on the camera lens will
have to be considered.
How to solve this problem:
be 1. Use the white side of the grey-card, this yields 21lr stops which will have to
deducted from the value measured. For that purpose, you set the white index line
(15) of LUNASIX F or LUNALITE on the scale (13) to -21/t. il
2. You measure with the lens wide open and compensate the difference in stops
I down to the working aperture by extending the exposure time accordingly.
H
h
E.View original page 11Page 12 · Read text
This is easily Oone OV using the computer ring (24) ot the LUNASIX F or LUNALITE
or (7) of LUNASIX 3: you rotate the ring until the exposure time indicated at the
reading index is opposite the maximum aperture of the lens. Shutter speed and
working aperture of the lens can be read on the scales as usual.
You may also measure without filters and then correct for filter factor subsequently
or set the ring for correcting factors (23) of LUNASIX F or LUNALITE.
Determination of tndlvidual reading index
1. By comparsion measurements:
Set up your camera to face a grey-card and take a reading. Then null the meter
with the computer ring and determine the shutter speed corresponding to
the aperture set on your camera. Next take a reading of the grey-card off the
camera ground glass. Note the f/stop that appears opposite the exposure time
determined when reading the grey-card directly. This is your individual reading
index.
2. For calibration use an average scene for which the optimum shutter speeds
and f/stops are known. Set that previously determined aperture on your camera,
the shutter speed is known or tested again by taking a test photo. Next measure
through the ground glass at the most important part of the subject and null the
meter again. Your reading inciex is the f/stop which appears opposite the ex-
posure time previously determined.
For future reference mark that index on the system exposure meter with one of
the stickers supplied (see illustrations pages 11 and 12).
10
l
LView original page 12Page 13 · Read text
Example LUNASIX F or LUNALITE
Your film speed is 19 DlN. Your
MEASURING PROBE yields a shut-
ter speed of 1/rs sec. for the aper-
ture B set on your camera. f /0.7*2/s
stops is then indicated opposite
r/rs sec. and this is your individual
reading index.
11View original page 13Page 15 · Read text
Contrast measdrement
For this type of works adjust the LUNASIX F or LUNALITE for extended meas-
urement.
Subject contrast
Measure brightest and darkest spot either direct at the subject (see page 5) or on
the ground glass (see page 6). The difference of the scale values indicated is the
subject contrast expressed in exposure stops.
lllumination contrast
Use a grey-card for measuring the weaker general light and the effect light (see:
"measuring the illumination intensity" page 16). The difference in readings obtained
in those two measurements is the illumination contrast which you can modify in
case of need by shifting the lamps.
The admissible contrast depends on the job requirements, the film and the photo-
graphic paper used. Please refer to manufacturers, recommendations.
Denslty measurement
Density measurements can be taken of film negatives and transparencies using
the MEASURING PROBE and a light box. For accurate readings the light box must
be uniform in intensity, or a uniform section of the box used for measuring pur-
poses.
13View original page 15Page 16 · Read text
To measure the a6solute density of an area of film, first take a reading of the light
box by itself. Record the scale value obtained as So. Next place the area of the film
to be measured over the very same spot on the light box and take a reading with
the system exposure meter. Record the scale value as SN. The density of the film
can be calculated from the formula:
r D=O.3(So-SN)
| change of one exposure value equals a density change of 0.3. The 1/r marks the scale are equivalent to a density change of 0'1'II on=ach
Example:
Scale reading when measuring without film: So = 18r/r
When measuring with film on the light box: SN = 152/r
D = 0.3 (18r/r -152/i: 0.3 x22lz = 0.3x8/s - 0'8
The density of the area measured is 0.8
Density range of the film is the difference in density between the lightest area and
the darkest area. For determining the density contrast, first take a reading at the
iigntesi area (scale value S,o".) ind the darkest area of the negative (scale value
S.in.).
The contrast K can be calculated from the formula:
K - 0.3 (S'o". - S'in.) Depending on the requirements of the work in hand (enlarging of paper pictures,
preparatio-ns for printings etc.) be sure to mind the instructions for the admissible
density contrast.
14View original page 16Page 18 · Read text
Measuremenf of illumination intensity For measuring the illumination intensity Exposure values illumination intensity at very small areas the system expos- LW/EV lx fc ure meter is often too big. For these jobs you can employ the MEASURING -3 0.7 0.064 PROBE and a small grey-card. Place -2 1.4 o.'t25 the grey-card on the area of which the -1 2.8 o.25 illumination intensity has to be meas- 0 5.5 0.5 ured, so that it obtains the same illu- 1 11 1 mination as the subject to be mea- 2 222 sured. 3 444 Subsequently point the measuring aper- 4 888 ture of the MEASURING PROBE to 5 175 16 the grey-card while observing that the 6 350 32 area to be measured will not be sha- 700 64 dowed. The distance should be close 1400 125enough to prevent the adjacent surr- 7II 2800 250 ounding area falsifying the measure- 10 5500 500 ment (see footnote page 5). 11 1 1000 1000 I The illumination intensities in Lux (lx) 12 22000 2000 and footcandle (fc) corresponding to 13 44000 4000the EV (exposure values) while sys- 14 88000 8000tem exposure meter set at DIN 18 (50 ASA) values can be seen from 15 175000 16000 the following table: 16 350000 32000 These data are valid for a neutral grey-card with a luminance factor of 0.18. 16View original page 18
Page 19 · Read text
Note:
We also manufacture special luxmeters and footcandle meters such as PANLUX
electronic and MAVOLUX electronic. They meet all requirements as to cosine
correction an Vl" curves in the proper sense of the laws of physics. These meters
are also ideal for all experts in lighting and illumination.
lf repair or adjustment should ever become necessary please send your MEASURING
PROBE carefully packed to
GOSSEN GMBH
Servicestelle B
NdgelsbachstraBe 25
D-8520 Erlangen
or to the GOSSEN agency in your own country.
acces-I to.expedite handling please send your MEASURING PROBE ony without
l'oI