Camera accessories
Kodak Medalist Accessory Back instructions User manual
User manual for Kodak Medalist Accessory Back instructions. 9 pages in English. Read the original PDF, download or print a copy without registration.
9 pagesEnglish0.5 MB PDF

Loading your manual…Open PDF directly
Document details
- Brand
- Kodak
- Model / document
- Kodak Medalist Accessory Back instructions
- Document type
- User manual
- Language
- English
- Pages
- 9
- File size
- 0.5 MB
- Category
- Camera accessories
- Document date
- Not specified in catalog
Search available document text
Find a term, then jump to its page in the original PDF. Image-only pages may not be searchable; check the PDF for exact wording and diagrams.
Page 3 · Read text
4-
O With the Acc.rrory,-Buq& the KodakMedallpt-canB be
used with sheet film, filrn packs, or platd;" ' 'n
The Accessory Back is built for precision adjustment to
each individual camera'. Once this adjustment is made,
the back will be parallr:l to the roll film plane so that the
entire area of the film or plate will be in exact focus. Do
not attempt to attach or use the ba,ck fufory tke adjustment is rnade.
www.butkus.usView original page 3Page 4 · Read text
Follow these instructions carefully-the back may be
damaged if attached to the Medalist when improperly
adjusted. i
7. Remove the ground glass panel from the back as
described on page 5.
2. With a jeweler's screwdriver, check the two screws
in each corn&r of the back frame (see illustration
below). Turn the HneDLEss scREws clockwise as far
as they will go. Turn the FLAT HEAD scREws clock-
wise as far as they will go; then turn them three cum-
plete turns in a counterclockwise direction.
3. Attach the back to the camera (see page 4) .
4. With a jeweler's screr,vdrivcr, tui'n the flat head
screws clockwise until the corners of the inner edges
of the Accessory Baek just conre in contact with
the roll filg\ tra-qk of the camera.
This isi\ a precision, adjustment-turn the screws
gently with a jeweler's screwdriver.View original page 4Page 5 · Read text
5. Finally, turn the headless screws counterclockwise
as far as they will go.
6. As a final check, replace the ground glass as
described on page 5 and with the lens wide open,
focus (see page 5) on a large wall chart or calendar
which is parallel to the ground glass. The image
should be sharp over the entire area of the ground
glass.
When this adjustment is made, no further adjust- 'ments should be necessary.
Remove the regular camera back and, tuith the lens "fulll retracted, attach the Ar:cessory Back with the rercn for
the ground glass panel as shown. The small LUG engages
in the hole below tl4e snurrER cocKrNG LEVEn to make
the range finder, focusing scale, and automatic paral-
lax ad.justment o of the view finder function properly
when the Accessory Back is used. They witl not operate
correctly unless the lens isfulQ retracted when the Accessory
- Back is attached to $e Msdalist.
www.butkus.usView original page 5Page 6 · Read text
To Remove the Grovnd Glqss Fqnel--Lift up the
latch, draw down on the small HrNGE cATCr{, urra hft
off the ground glass panel.
To Reploce the Ground Gloss ponel-Hold the panel
so that it is nearly closed; position the bottom hinge pin;
then depress the small hinge catch to position the upper
hinge pin.
Follow these easy sreps when using the Accessory Back
with the Kodak Medalist I or the Kodak Medalist II.
l. rocus AND coMposE THE ptc'TURE. use either the
range finder a+d vicw finder of the carnera, or
use the ground glass panel of the Accessory Back.
To focus on the g*iound glass panel, first screw
a Kodak ,T.B.I* cable Release into the cABLE
RELEASE socKET. 'Ihen set the red index on the
shutter speed ring to "B" anc. cock the shutter r,vith
the shutter cocking lever-':s":.. *pi_ _,i t I +View original page 6Page 7 · Read text
'I'Ltrn thc circular piecc ort the T.B.I.
Cable Relcase so that thc notch on the
edge is directly under the small button
(see illustration). Press the push pin of
the cable release to open the shutter.
Press the small button directly above the
circular piece to closc thc shutter.
To facilitate critical focusing, a srnall
magnifier is attached to the focusing hood.
The black ett:hed line on the ground glass indi-
cates the lirnits of the picture area with 2% x 3rA-
inch film. With 6.5 x 9-cm film, the picturc area
covers the wholc ground glass.
2. POSITION THE FltM. Rernovc or srving asidc the ground
glass focusing p;lnel; then slide the proper Kodak
Film Pack Adapter or Kodak Cornbination Film
and Plate I'{oicit:r into positiorr. T'u rcrrlo\"c, siving
the rocr aside artd withdrarv the adapter or holder.
To use Kodak Fihn Packs No. 520, obtain a
2% x 3%-inch Kodak Film Pack Adaptcr.
To use sheet films or plates, obtain either the
6.5 x 9-cm or th,: 2% x 3r/-inch Kodak Combina-
tion Film and Plate Holder.
3. COCK THE SHUTTER rvith the shutter'. cocking levcr.
4. SET THE LENS OPENTNG AND SHUTTER SPEED for the
correct exposure.
5. MAKE THE EXPoSURE. With the Kodak Medalist I,
use the Kodak T.B"I. Cable Release No. 2; the
shutter release is inoperative and cannot be used.
With the Kodak Medalist II, either the snurrER
www.butkus.usView original page 7Page 8 · Read text
RELEAsE or the T.B.I. Cable Release may be used.
Time exposures are made in the same
way as described for focusing on the
ground glass.
To make instantaneous and bulb
exposures with the T.B.I. Cable Release ,
turn the circular piece of the cable
release so that it slides under the smzrll
button as shown in the illustration.
Press the push pin of the cable release
to make the exposure; it wiil spring
back to its original position when the
finger is removed.
Kodok Portro Lenses rnay be used to photograph sub-
jects closer than 311 feet-for close-up photography and
copying.
'Io ttse a Kodak Portra l-,ens) Llnscre\ti the insert from
the front of the camera lens mount and place the Portra
Lens, convex side fonvard, in front of the camera lens. If
a filter is used, be sure to place the supplementary lens
next to the camera lens. S'{'AY 9, uj
Always place the camera on a tripod or other firm sup-
port and focus with the ground glass--the view finder
and range finder will not give correr:t settings with the
P<.rrtra Lenses. With the Kodak Medalist I; make"the
exposure with the T.B.I. Cable Release. With the Kodak
Medalist II, use the T.B.I. Cable Release whenever the
lens is retracted from a normal picture-taking position
(as indicated by the focusing scale).
Subfecl Dislonces and Approximste Field Sizes for
the Kodak Portra Lenses with Accessory Back andView original page 8From the M. Butkus archive. Original publisher and archive notices are retained.
Check the model and edition against your equipment.
PDF verified 2026-10-10.
