METALLOPLAN
 LargefieldMetallographicMicroscope



 Instructions





  I    Technicaldescription                                                3
 2    Technicaldetails                                                    4
 2.1 FSA-GWbinoculartube                                              5
 2.2  Objectives                                                         5
 2.3 Eyepieces                                                        8
 2.4  Vertical illuminatorfor incident-lightbrightfield                                                   I
 2.5  Vertical illuminator for incident-lightphase contrast                                           I
@    Verticatiltuminator for incident-lightbrightfield/darkground             1 0
 2.7 Lamp Housing100                                                 1 1
 3   Assemblingthe microscope                                         1 2
 4   Operatingthe microscope                                           1 4
 4.1  Incident-lightbrightfield_                                            1 4
 4.2  Incident-lightphase contrast                                        1 6
      Incident-lightbrightfield/darkground                                 1 8@
 5   Variotube                                                     20
 6   Micro-hardnesstester                                          21
 7   Photomicrography                                              22
 7.1  4 x 5in large-formatcamera                                        22
 7.2 Photomicrographywith the 4 x 5in large-formatcamera                 24
 7.3 4 x 5in large-formatcamera with f ully automatic exposure control __=    26
 7.4 ORTHOMATfully automaticmicroscopecamera
 7.5 Micro-attachmentfor the LEICAwith vibrationdamper
 7.6  Attachmentcamera with CB 100 Polaroid back
 a   Care and maintenance                                       30
     Magnificationtable                                           32
     Appendix:particlesize determinationaccording to snyder-Graff        32
                         www.orphancameras.com
,#&ds"  ,i&'*     .,.s     &:*;;r**r*#i@@;.     -&     lMrd&""                g.-     :*.xw*zu              ii**iiit*.,    -*.
View original page 3
Page 4 · Read text
F i g . 1                                                                                            I  Co-axialcontrols for the mechanicaladjustment
METALLOPLANLargefield M icroscope                     of the sample
                                             10 Plastic handrest
1  Detachablecap in the photo tube                11 Lever for operatingthe beam splitter
2 GW/CC eyepieces  in  the  eyepiece tubes     12 Locking lever f or tube changing
3 Knob for adjusting the interpupillarydistance     13 Lamp Housing100
4  Slot for f ilter slide                            14 Bayonetring for attachingthe lamp housing
5 Clampingscrew for the illuminator              15 Changing knob f or the swing-outlens
6  Verticalilluminator(interchangeable)           16 Coarse adjustment
7  Object holder                               17 Fine adjustment
B Large square mechanical stage No. 661
View original page 4
Page 5 · Read text
I Teclrnical    description


 The stand rests on 4 built-in vibration  illuminator 1.6 can be interchanged
 damping special plastic supports. The   horizontallywithout the need for lower.
 co-axialfine and coarse adjustmentFig.   ing the object stage.
 1.16. and 17 acts directly on the object  The light collar between the vertical
 stage 1.8. The   f ine adjustment 1.17  illuminator and the  light aperture in
 operates throughout the total travel of   the stand has 2 filter slots.
 40mm. One interval on the fine adjust-  The standard outfit of the METALLO-
 ment drum correspondsto 1 pm.       PLAN metallographic microscope in-
 The largefield binocular tube with ver-  cludes a Lamp Housing 100, Fig. 1.13.
 tical photo-tube is joined to the stand   Like the Lamp Housing 250 or mirror
 by means of a bayonet lock. lt can be   housing, which are also attachable,it
 rotated through 360o. The mechanical  is directly joined to the microscope by
 tube length compensator1.3 built into  means of the bayonetlock 1.14.
 the tube maintainssimultaneousfocus-
 ing in the film plane and eyepiece for
 all  interpupillary distances; refocus-
 ing for photomicrographyhas become
 unnecessary.
 A beam splitter in the tube directs 80 %
 of the total light into the photo-tubeand
 20 o/ointo the eyepiece tube. The beam
 splitter 1.11 can be swung out of the
 optical path so that the fult light flux is
 directed into the eyepiecetubes for ob-
 servation.
 The eyepiece tubes are designed to
 accept  largefield  eyepieces 1.2  of
 30mm  diameter.  23.2mm  diameter
 PERIPLAN@eyepieces are used with
 adapters.
 The object stage 1.8 is interchangeable
 on a dovetailslide and can be lowered
 considerablyfor high objects. The co-
 axial control of the stage 1.9 must be
 operated from the right. The vertical





  * Fig. 1 . 1 6 i n d i c a t e s i t e m '16 ,Fig . 1 .
                         www.orphancameras.com

^ o ' i * F ! i , r
View original page 5
Page 6 · Read text
2 Technical    details





Abb. 2
Beam in the METALLOPLAN



The various components such as ob-
ject stage, tubes, vertical illuminator,
 etc., are described in detail in our list
No. 560-24METALLOPLAN.The follow-
 ing paragraphs contain the directions
 necessaryfor operation.
View original page 6
Page 7 · Read text
2.1 Tube                               2.2  Objectives
The FSA-GW binocular tube for the   Every LEITZ microscope objective has
METALLOPLANhas been designed to   a number of detailsengraved:
accept eyepieces of 30mm diameter. lt
has a hinged beam splittingprism 3.11,  co,these objectiveshavebeen computed
which divides the beam at a 4:1 r'atioof   for  the tube length "infinity". This                                                                                                                              r                                                                                                                                                                                             i f ight intensities(80% for photomicro- means that  the  intermediate image
graphy, 20 o/ofor visual observation)or    is formed at  infinity. Only when a
directs the entire light f lux into the eye-  tube lens, a system of 200mm focal
piece tubes. The interpupillarydistance  length permanentlybuilt into the ver-
is set with the knurled knob 3.3. Here   tical illuminatorfor incident-lightbright-
the optical length compensationmain-   field,  is used  will  the  intermediate
tains critical focusing both in the eye-  image be formed in the eyepiecetube.                                                                                                                                                       :piece and in the film plane irrespective The magnificationdifference produced
of  interpupillarydistance. When this  by the tube lens is called the tube fac-
value  is unknown the  interpupillary tor, which is engraved on the vertical
distancesetting is adjusted during bin-   illuminator.lt must be allowed for when
ocular observationuntil only a single  the  total magnification is calculated
circular and easily surveyed field of   (see also table on p. 32).
view is seen. In addition,the GW- and
the GG eyepieces have focusing eye-
lenses.                                                                                                                                                                                                                                                                                                                                           rIII
Eyepiecesof 23.2mmdiameter are used
with adapters,Code No. 513 256.



                            J





                                         r8407- 5r3                                                  18735- 519

F i g . 3                                              F i g . 4
FSA-GW binocular tube                                    Pl Oel 160/1.40incident-light objective
                        www.orphancameras.com
View original page 7
Page 8 · Read text
DO: objectives can be used with or   ce betweenthe objectivefront lens and
without coverglass,O: objectives must   the top surface of the object) differs in
not be used with coverglass.             the  individual objectives because of
These details can also be found in the   their differenttotal length.
table on p. 7. Below the detail of tube  The tables on the facing page provide
length and coverglass correction the   information on all important details.
followingdata will be found:
Reproductionratio, e.g. 32 x, numerical
aperture, e.g. /0.50. ln  addition, the
state of correction is indicated by cer-
tain letters in front of the magnification
value:
Pl    -  plano objective
Fl     :  fluoritesystem
Apo :  apochromat
R      :  radiation-resistantobjective
Objectives without any letters in front
of the magnificationvalue are convent-
ional achromats.
Objectives to be used only in an im-
mersion medium (e.g. immersion oil)
are engraved to this effect (e.9. Pl Apo
Oel160x/1.40).In additionall immersion
objectives have a  black ring  in the
bottom third of the objective mount for
quick identification.Incident-lightphase
contrast objectives have the additional
designationPhaco.
Objectivesfor incident-lightbrightfield/
darkground observation have the de-
signationHD.
All high-power systems have a spring-
loaded front mount to protect the front
lens.
All LEITZ-incident-lightobjectives for
metallographic microscopes have an
adjustmentlength of 45mm. This means
that after correct focusing the distance
between the shoulder of the objective
in the revolvingnosepiece and the top
surface of the object is 45mm. Change
of  magnification therefore  requires
only minor refocusingwith the fine ad-
justment.The working distance (distan-


                                                                                                                                                                                                                               .ld                                                                                                                                            .
View original page 8
Page 10 · Read text
2.3  Eyepieces                         High-point eyepieces have a pupillary
In the optical system of the microscope  distance of about 20mm and therefore
objective and eyepiece form a unit. In   allow observation through spectacles
the METALLOPLAN largefield micro-  and thus a compensationof the astig-
scope field-of-viewindices of up to 28  matism of the eye. The upper rim of the
can be obtaineddependingon the op-   high-pointeyepiecesconsists of a spe-
tical equipment.The field of view of an   cial  plastic material which prevents
eyepieceis the area of the intermediate  scratcheson the spectaclelenses.
image in the tube that can be surveyed  The tables below list the eyepiecesthat
with the eyepiece.The diameter of the  can be used on the METALLOPLAN
image formed by a GW 6.3 x eyepiece  metallographicmicroscope.
of 28mm field-of-viewdiameter (field-of-
view index 28) appears to have the same
dimension as the diameter 6.3 x 28 :    GW PERIPLANwidefield eyepieces
                                (30mm @)176mm of an area at a distance of
250mm in front of the observer.At this    Designation  Field-of-viewindex
size the image can also be reproduced                     28                            .-c_cw-a9u250mmabovethe eyepieceon a ground-   G W S x            26
glass screen.                  G W 1 0 x           24
                     GW10x M          24
                                     High-pointeyepieces
                      GW6.3x           28
                     GW10x            22



                              GF PERIPLANwidefield eyepieces
Object field                           (23.2mm Q)
 lf the diameter of the field of view is                             G F 1 0 x              1 8
divided by the objective magnification                             G F 1 0 x M            1 8
and the tube factor the diameter of the                             GF 12,5x             1 8
object field that can be observed is ob-                             GF 12,5x M           1 8
tained. With the above-mentionedeye-                             G F 1 6 x              1 5
piece and a 32 x/0.50 objective and                             G F 2 5 x              1 0
0.8x tube factor an object field of                             G F 2 5 x M            1 0
  28
              : 1.1mmdiameterwill be ob-
32'o'8         served.
Eyepieces are generally computed so   Further details of objectives,eyepieces,
 that the observer's eye must be about  and availablegraticulesfor GF and GW
8 to 10mm above the top surface of the  PERIPLANeyepieces are contained in
eyelens of the eyepiece.This is called  our list "lmage-formingand llluminating
the pupillarydistance.               Systemsof the Microscope" No. 512-99.
View original page 10
Page 11 · Read text
2.4 Vertical illuminator for incident-      2.5  Vertical illuminator
      light brightfield with plano                   for incident-light phase contrast
     objectives                     The vertical illuminator consists of the
The vertical illuminator consists of the   horizontalchangingslide 6.18,the quin-
horizontal changing slide 5.18, the   tuple objectiverevolvingnosepiece6.22,
quintupleobjective revolvingnosepiece  and a  rotating light ring drum 6.30
5.22 tor plano objectives5.23, an aper-  which contains 4 annular stops for the
ture 5.26 and a field diaphragm 5.25 in   various magnifications in phase con-
the light tube 5.24, which houses the   trast and a changing lever 6.29 for
ifluminating optical system 5.21. The   brightfield illumination.The 1 x tube
0.8x tube lens system 5.19 is installed  lens system 6.19 is  installed in the
in the changing slide. The objective  changingslide.The final magnifications
revolving nosepiece has 5 threaded  obtained with a 10x eyepieceare en-
bushes for the objectives.The bushes  graved 6.27 on the light ring drum. The
are numbered. Each outfit is accom-  annular stop necessaryfor the required
panied by an objective/eyepiecechart.  magnification is  in the  optical path
Among other information it indicates  when the final magnification value is
which nosepiece thread the individual  engaged in the top right as seen by
objectives are matched with. lf possible  the observer.The annular stop for 50 x
the objectives should not be removed  magnification also serves for  100x
from the nosepiece. Should this be-   magnification.For observationin bright-
come necessary, care must be taken   field the drum can be set so that the
that they are replaced in their proper  word "hell" (German for bright) is set
threadedbush.                        insteadof a magnificationvalue.




         ba/*,,rs.,t'q
         1 8    1 9





F i g . 5                                              F i g . 6
Vertical  illuminator  for  incident-light  brightfield        Vertical illuminator for incident-light phase contrast
20  Lever for decentring the aperture diaphragm       28  Setting ring of the aperture diaphragm
                        www.orphancameras.com
View original page 11
Page 13 · Read text
For  comparison of  brightfield and
 phase contrast the changing lever 6.29
 can be operated so that the phase con-
 trast beam is modified to give bright-
 field illuminationsuitablefor comparison
 purposes.The individualannular stops
 for phase contrast are permanently
 centred in the factory before despatch,
 so that recentringwill not be required.
 Should, however, resetting of an annu-
  far stop become necessary,the direc-
 tions given in our list No. 560-6 should
 be followed.





-,[ 2.6 Iertical illuminator\-1or         brightfieldand darkground





                                                                                                                17083a - 560

  F i g . 7
  Further details will be found in Instructions No. 560-23.
                             www.orphancameras.com1 0
View original page 13
Page 14 · Read text
2.7 Lamp Housing 100               lamp 9.37 into the mount, turn it to the
The Lamp Housing100 is designedfor    left and remove it.
the use of light sources of up to 100W.
fts normal version has a 2-lens frosted  Insertionof the new lamp:
condenser,which for microphotometry  insert the filament lamp with the broad
must be replaced by a non-frostedone.   lug in the larger recess of the lamp
The large connecting tube 8.35 with  mount, lightly push it in and lock it by
bayonet lock 8.14 is mounted on the   a turn to the right. Fully insertthe lamp
housing with the cooling louvres.The  mount into the tube and clamp it by
connectingtube accepts the 3 f ilters.On  meansof the grub screw.
the top is the knob 8.32 for the vertical  Evenly illuminate the rear focal plane
adjustmentof the lamp, and on the left   of the objective by adjusting the lamp
(as seen by the observer) the controls  condenser 9.36 and simultaneousob-
for the lamp condenser8.33 and for the   servation through the eyepiece tube.
horizontaladjustmeni8.34 of the lamp.  With the 12v 60W filament lamp cen-
The lamp housing can be opened on   tration is not necessary.Thecentration
the right after the knurled screw 8.31  of the 12 v 100W tungsten halogen
has been unscrewed.                lamp is describedon p. 14 in the sec-
The lamp housing need not be opened  tion "Operatingthe microscope".
for the excirangeof the 12v 60 W fila-  The Instructions514-119 contain de-
ment lamp. For this purpose only the   tailed directionsabout other lamps and
lamp mount 9.38 is pulled out of the   their use in the Lamp Housing.100 or
housing. Lightly push  the  filament 100z.





            33 34   3s  14                             38
                                                    1 8 5 1 -r 5 1 4                                                17369-514

F i g . B                                              F i g . 9
L a m p H o u s i n g 1 0 0                                                                                              l n t e r c h a n g i n gt h e  f i l a m e n t l a m p

                                   1 1
View original page 14
Page 15 · Read text
3 AsserTrlrling   the  rTricroscope





F i g . 1 0                                             F i g . 1 1
41  Drive casing
Release clamping screw 10.40, insert  Insertthe diaphragmtube into the light
object stage No. 661 10.8 in the chang-  aperture.
ing guide 10.39 and lower it as far as
possible.





 Fig .12                                             F i g . 1 3
By means of the coarse adjustment  Depressthe locking lever 13.12and in-
lower the stage so that after the clamp-   sert the tube into the bayonetchanging
ing screw 1.5 is released the vertical  mount from above, at any rotation posi-
illuminatorcan be easily and fully in-   tion. Release the locking lever 13.12.
serted into the  horizontal changing  After insertion it must be possible to
guide. Retighten the clamping screw.   rotate the tube through 360" without
Dependingon the height of the object   effort. lf the tube is to be clamped in a
 raise the stage and fix it with clamping  certain position,lightly pull the locking
screw 10.40.                           lever13.12out.
                            www.orphancameras.com                                1 2
View original page 15
Page 16 · Read text
F i g . 1 4

Adjust the bayonet ring on the Lamp
Housing 100 so that the red dot on the
bayonet ring and lamp housing face
each other. Attach the lamp housing
to the stand and lock it by rotating the
bayonet to the right. Connect the lamp
housingto the mainsvia its transformer.
Further information can be obtained
f rom the Instructions " Lamp Housing
100 and 100Z" No. 514-119.





                                1 3
View original page 16
Page 17 · Read text
4 Operating    the  lTticroscope


4.1  Vertical illuminator for incident-     Turn the regulatingknob on the trans-
     light brightfield                    former to switch on the lamp and set
The sample (polished section) on the   the brightness most favourablefor vi-
metal object slide is pressed into pla-   sual observation (about 4amp for the
sticine by means of a handpresswhich  12v 60 W lamp) with it. The 12v 60 W
must be kept in its lower position for  lamp in the Lamp Housing 100 is pre-
some time so that the surplusplasticine  centred. Centration is therefore unne-
can be squeezed out from under the   cessary. Recentrationis required when
block. The alignment of the polished  a 12v 100W tungsten halogen lamp is
section to the optical axis requiresonly  used.This is done with the verticalillu-
a few seconds' preparationper section.  minator removed. The image of the
The handpresshas an adjustablestop   fight source is projected onto a cen-
to match the samples at the same level.  tring disc held in front of the light
As a result,series investigationsrequire  aperture of the diaphragm tube and
only minor refocusingwith the fine ad-  focused by adjustment of  the lamp
justment every time a sample is chang-  condenser16.33.This light area is cen-
                                         tred to the light aperture by means ofed. In addition, the objectives do not
                                       the vertical and/or lateral adjustmentcollide with the sample when the re-
                                   16.32and 16.34on the Lamp Housingvolving nosepieceis rotated for magni-
                                    100.Furtherdetailsare containedin In-ficationchange.
                                        structionsNo. 514-119.





F i g . 1 5                                             F i g . 1 6
Handpress with various polished sections              Side view of the Lamp Housing 100
                            www.orphancameras.com                                   1 4
View original page 17
Page 18 · Read text
Replace the  vertical  illuminator as  Close the aperture diaphragm until the
      shown on Fig. 12, p.12.                 best possible contrast, but also opti-
       Turn  in a low-power objective (e.g. mum resolution of the object is ob-
        Pl 8x/0.18).Close the field diaphragm,  tained. Ensureoptimum illuminationby
      open the aperture diaphragm,turn out   adjustment of the lamp condenser onItII       the eyelens of the eyepieces until the   the Lamp Housing100.I,r
       engravedmarking ring becomesvisible.  The desired brightness of the micro-
       Raise the object stage with the polish-  scopic image must not be produced by
       ed section in position by means of the  adjustment of the aperture diaphragm
       coarse adjustment and move it a little  but only by  regulation of the lamp
        closer to the objective than the free   brightnesson the transformer.
       working distance indicated in the table
         (for the Pl 8 x/0.18 about 13mm). Ob-
       serve the image and lower the object
       stage until critical focusing has been
       achieved.
       This procedure preventsaccidental im-
       pact of the objective front lens on the
      sample and therefore damage to the
       objectiveor the sections.
      Open the field diaphragm so that  it
        just disappearsbeyond the edge of the
         field of view. This basic setting must be
       preserved for all objectives. When eye-
       pieces of different field-of-view indices
       are used a correspondingreadjustment
        of the field diaphragmis necessary.





                                      1 5
View original page 18
Page 20 · Read text
Rotate the eyelens of eyepieces with  Refocuswith the fine adjustment.lf ob-
graticulesso that a sharp image of the   servation in brightfield illuminationis
graticuleis obtained.                   intended,the drum must be rotated so
Turn in the 20 x/0.35 objective on the   that it engages at the word "hell" on
revolving nosepiece. Rotate the  light  the top right-hand side. This setting
ring drum so that the marking 200 ap-   applies to  all magnificationranges in
pears on the top right hand side and   brightfield.
ensure that the drum clicks into posi-    lf during the observationof an object in
tion.                             phase contrast comparisonwith bright-
Focus the microscopic image with the   fiefd is desired,the lever 17.29must be
coarse and fine adjustment. Replace  actuated. By pressure on this lever the
one of the eyepieces by the focusing  phase contrast beam  is modified to
magnifier.Rotate the eyelens of the fo-  produce brightfieldilluminationsuitable
cusing magnifieruntil the image of the   for general comparison purposeswith-
light and phase ring appears sharp.  out the need to change the setting of
Move the tilting object holder so that   the Iight ring drum. The observer is
the light and phase rings are in precise  thus able to view a given object in phase
register.After a change of magnification  contrast and in brightfieldin rapid suc-
recentringof the light and phase rings  cession.
is no longer necessary,but the correct
setting of the light ring drum for the
associated objective must be ensured.





                                                                                                           25561c - 513

Fig. 18  a phase ring centred, b phase ring off centre
                                   1 7
View original page 20
Page 21 · Read text
43  Investigationswith the vertical       the GW eyepieces until the marking
     illuminator for brightfield and         rings becomevisible.
    darkground                    Focus the object. Close the field dia-
The vertical illuminator for brightfield  phragm until it just disappearsbeyond
and darkground is used alternatelyfor   the rim of the field of view. Close the
investigationsin  brightfield or  dark-  aperturediaphragmuntil good contrast
ground. One of the two types of illumi-  becomesvisible in the object while op-
nation becomes effectivewhen the cen-  timum resolutionis still obtained.
tral diaphragm 19.43 is swung into or  To producedarkgroundilluminationthe
out of the beam.                         central stop is turned in (lever 43 is at
Remove the diaphragm tube from the   the rear stop). Fully open the field- and
upper light aperture. Insert the bright-  aperture diaphragffis,i.e. the 2 levers
field/darkgroundvertical iliuminatorin  on the tube are in a horizontalposition.
the horizontalchanging guide accord-  With darkground observation, slightly
ing to Fig. 12 p. 12. Place the sample  increase,if necessary,the brightnessof
on the object stage. Switch on the illu-  the lamp with the regulatingknob of the
mination by means of the regulating  transformer.Any filters (e.g. for photo-
knob of the transformer.               micrography)can be accommodatedin
Turn out the darkground central stop   the filter slot of the lamp housing. For
(lever 43 points to the front as seen by   further details consult InstructionsNo.
the operator).Turn out the eyelens of   560-23.





                -A r lFt; T                                              i::+N





                                                                                                             17A84b - 560

Fig. 19  Vertical illuminator for brightfield and darkground incident light
                            www.orphancameras.com1 8
View original page 21
Page 22 · Read text
Fig. 20 METALLOPLAN with projection attachment

                                   1 9
View original page 22
Page 23 · Read text
5 Vario   tulre


Although the Vario tube serves mainly   to 35mm photomicrography.
for observation,it is also a valuableaid





  ffi





Fig. 21 METALLOPLAN with Vario tube
                             www.orphancameras.com20
View original page 23
Page 25 · Read text
7 PhotorTricrography


General !nformation                   7 .1 4 x 5in large-formatcamera
These instructions have been written      on the METALLOPLAN
for the correct use and operationof our                                    44                             50
microscope and its associated acces-                                                                  51
sories.The operatoris assumedto have                                   45a knowledgeof photomicrographyand
microscopy;they are not an elementary
g u ide.
We are thereforeoutlining only a few
basic rules,which must be observed.   4C
1. The exact plane position of the ob-
ject.
2. Criticalfocusingof the image on the
groundglassscreen (largeformat)or in
the eyepiece or  focusing telescope  47
(35mm).
3. The accurate determinationof the
exposuretime.
4. Absolutecleanlinessof allthe optical
surfaces accessible to the user, such  47
as objective,tube lens, eyepiece etc.
(See section Care and maintenance). 49
Particularattentionmust be paid to the
followingpoints:
The usefulmagnification.
The choice of a light filter and of the
suitableexposurematerial.
The following outfits are avaiable for
photomicrography:
4 x Sin large-formatcamera
4 x Sin large-formatcamera with fully
automaticexposurecontrol
ORTHOMAT@f ullyautomaticmicroscope
camera
Micro-attachmentfor the LEICA@with
vibrationdamper
Systemattachmentcamera
CB 100Polaroidcamera                     47 Screwsfor fixing the guide rail                                                48 Cameracarrier
                                                49 Shuttersupport
                                                50 Pressuref rame and darkslideholder
                                               51  Mirror tilting lever
F i g . 2 3                                          52 Groundglassscreen
4 4 G u i d e r a i l                                    53  Large-format camera with rotating darkslide
45 M irror ref lex attach ment                                                           f rame
46 Clamping screw for the mirror ref lex attachment   54 Bellows
       ( n o t v i s i b l e  i n  i l l u s t r a t i o n )                      55 Bellows lock
                             www.orphancameras.com22
View original page 25
Page 27 · Read text
Attaching the 4 x 5in large-format         7.2 Pholomicrography with the 4 x 5in
cameta                                      large-format camera
Remove the lamp housing from the   After the microscopic image has been
stand. Connect the camera carrier 23.48  adjusted in the observation tube and
by means of the 2 bayonet locks with   the area of the sample to be photo-
the stand; for this purpose push the  graphed found  final focusing takes
lock downwards. Place the guide rail   place on the groundglassscreen of the
23.44 on the camera carrier 23.48 and   mirror reflexattachment:
screw it in positionwith the two screws
23.47.Place the lower light screening   1. Set the setting wheel 25.62at T and
collar 25.57 on the photo tube. Insert  open the central shutter with cable
the eyepiece in the photo tube. Turn   release 25.63.
out the eyelens of the eyepiece until  Turn  in the deflecting mirror of the
the engraved marking ring becomes  mirror reflex attachment,(lever 23.51 to
visible.                                the  rear);  if necessary readjust the
Slide the shutter support 25.49into the   lamp brightness".
guide rail (upper light screeningcollar   2. Set the desired picture area by ver-
25.61 pointing downwards) and lower   tical adjustment of the mirror reflex
it by hand or the knob 25.64 until the   attachment after releasing the clamp-
bottom edge of the upper light screen-   ing screw 23.46.lf necessary rotate the
ing collar is f lushwith the corresponding  mirror reflex attachmentto obtain the
marking on the lower light screening  optimum picture area. The clamping
collar. With the GW 10 x eyepiece, for   screw must be retightened after the
instance,it is the marking GW 10 x. See  adjustment of the mirror reflex attach-
Fig.24.                              ment.
Clamp the shutter support on the guide   3. Refocus the image on the ground-
rail.                                  glass screen 23.52with the fine adjust-
Slide the large-formatcamera into the  ment of the microscope.
guide rail and clamp it in positionwith  Use the focusing magnifier.
screw 23.46.                               First set the magnifierfor your own eye-
Lock the bellows of the large-format  sight: place  it  in the centre of the
camera 23.55.                       groundglassscreen and focus it on the
Screw the cable releaseinto the thread-  crosslines marked on the screen; do
ed bush on the shutter support.          not move the eye too close to the ma-
Replacethe lamp housing.               gnifier.
                                            4. Set the field diaphragmof the micro-
                                  scope so that it just disappearsbeyond
                                       the edge of the groundglassscreen.

                                                     *                                                for  colour photography the colour
                                    temperature of the filament bulb must
                                  be matched with that for which the co-
                                          lour film has been sensitized.
                             www.orphancameras.com24
                                                                                                                           tu::.,     -
View original page 27

From the M. Butkus archive. Original publisher and archive notices are retained.
Check the model and edition against your equipment.

PDF verified 2026-10-10.