Home/Butkus archive/Mamiya
Film cameras

Mamiya C33 User manual

User manual for Mamiya C33. 20 pages in English. Read the original PDF, download or print a copy without registration.

20 pagesEnglish2.3 MB PDF
Mamiya C33 manual cover
Read the manual Original PDF
Download PDF
Loading your manual…Open PDF directly

Document details

Brand
Mamiya
Model / document
Mamiya C33
Document type
User manual
Language
English
Pages
20
File size
2.3 MB
Category
Film cameras
Document date
Not specified in catalog

Search available document text

Find a term, then jump to its page in the original PDF. Image-only pages may not be searchable; check the PDF for exact wording and diagrams.

Page 4 · Read text
www.orphancameras.com
14. Parallax Correction Lever     27. Red Window Cover        31. Take-LIp Spool Catch Stud
15. Filmspeed (ASA) Dial         28. Film Chamber             32. Start Marks (right and left)
16. Shutter  Cocking  Lever     29. Film Spool Catch Stud     33. Backlid Hinge Release
    (body assembly)                                 30. Take-Up Spool Chamber   34. Tripod Socket
L7. Shutter  Cocking  Lever
    (lens-shutter assembly)
18. Synchroflash   Terminal
    (lens-shutter assembly)
19. Synchroflash M-X Selector
    (lens-shutter assembly)
20. Distance Scale (right)
2L. Distance Scale (left)
22. Distance Scale (left)
23. Strap Eyelets (right and
     left)
24. Accessory Clip
25. Focusing Hood Lock Screw
26. Backlid Catch Button


                                     2
View original page 4
Page 5 · Read text
www.orphancameras.com
           FOCUSINGHOOD OPERATION
1. The focusing hood will snap erect when the fobusing hood front @ is  lifterl up from the
   rear. (Fig.  l)
2. Slight pressure on the upper section of the viewfinder flap @ will  release the magnifying
   glass @ which  will spring into proper position over the ground gtass viewing and focusing
  screen.(Fig.2)
3. When the frame viewfinder flap @ is pushed down fully  it  will catch and remain over the
  ground glass' This permits eye level viewfinding for the 80mm lens. When frame view-
   finder @ is pushed down until  it catches the direct view covers the area of the 65mm
   lens. (Fig. 3)
4. To release the frame viewfinder @ and flap @ for returning to original position, first push
   in the left side plate (as seen from the rear) of focusing hood then push in the right side
View original page 5
Page 6 · Read text
www.orphancameras.com
     plate.  (Fig.  4)
 5. To  collapse and fold  the focusing  hood,  first see that the frame viewfinder  flap @ is closed,
    then  fold down  the magnifying  glass O.   Fold down  the  side  plates and  the  back; hold
   momentarily  while  folding  back  the focusing hood front  @.
                  FOCUStNc
 1. The method  of focusing  is the same as for any twin-lens  reflex camera.   Turn  either  of
   the focusing knobs @ while keeping the image  of  your  subject  centered on  the ground
   glass screen.
2. when  using the frame  viewfinder  with  lOs mm,  l3s mm  or 180mm  lenses mounted on the
   camera, be sure to attach proper  auxiliary  mask  to the mask studs @.
            IENS CHANGING
1. Before removing  or  fitting  a  lens-shutter  assembly  turn  focusing
   knob @ to make certain that the lens mount  is fully retracted into
   the camera body.
2. Turn   the  filmwind   crank   cottnter clockwise  ancl reset  in  bocly
   housing position. (Fig. 5)
3. Turn  lens-shutter assernbly change knob @ to,.uNI-ocK".    (Fig.6)
4. Press down knurled  head  of  the  lens-shutter assembly catch @,
                                  4
View original page 6
Page 7 · Read text
www.orphancameras.com
  and allow  it to swing out forward.  The lens-shutterassemblycan then be lifted out. (Fig. 7)
5' To attach a lens-shutter assembly, lower carefully into position on the lens mount, then
  secure in place by replacing the lens-shutter assembly catch @, turn the lens-shutter assembly
  change knob @ to "LOCK".
  CAuIloN:   Shutter cocking lever @ cannot be meshed with the shutter cocking lever @
   in lens-shutter assembly unless the filmwind crank  is returned to  its  original position.
  Mount and secure the lens when these two levers are properly meshed. (FiS. 8)
6. A red warning signal visible under the ground glass screen indicates that the lens-shutter
  assembly change knob @ is at "UNLOCK"  position; shutter becomes inoperative and filnr
   is automatically protected from light.
7. After lens changing is completed, adjust the parallax correction lever to the index figure
  given on the lens mount.  However, when the 65mm lens is mounted, set thelever. at 80
  and attach the accessoryparallax correction plate (packedwith the lens) to the hood. (Fig. g)
View original page 7
Page 8 · Read text
www.orphancameras.com





                      FIIM TOADING
 1. To open backlid,  first turn  backlid catch button @ so that  the red dot is aligned vertically,
   then push  to the  right,  in the direction indicated by the arrow mark  (Fig. 10). The backlid
    will be released, and the exposure counter @  will be reset at  .,O,,.
2' Loading and unloading film is done in the same way as with other twin-lens reflex cameras.
  However, before loading always make certain that the multiple  exposure/filmstop selector
 @ is turned to "ROLLFILM".   In this position, you are assured that the shutter button
 @ cannot be operated for releaseof shutter unless the film has been wound and advanced
  one frame. (Fig. 11)
3' After the film has been positioned over the film gate, and the end has been secured to
  the take'up spool, turn the filmwind crank @, winding until the start mark (double-headed

                                    6
View original page 8
Page 9 · Read text
www.orphancameras.com
                           arrow) printed on the paper backing of the film comes into alignment
                             with  the start marks @ near the upper side of the film gate (Fig. 12).
                         Close backlid, and lock by turning  the backlid  catch  button  down
                         toward  the  left.
                    CAUTION :  When  closing the back, always press the  right  side of
                            the catch button  tightly  so  that  both  right  and  left  sides of  the
                         back are securely engaged to the body. (Fig. 13)
                            4. Turn  filmwind  crank @  in clockwise direction  untit   it stops.  The
    first frame of film will be in correct position for exposure, while the exposure counter @
   will indicate numeral 1.
   Shutter  will be cocked by one stroke  of the filmwind  crank.   After advancing the  film the
   filmwind  crank must be turned  in counterclockwise  direction  until   it  stops.  Shutter  will
   not operate unless the  crank   is  returned  to  its  original  position;
   never force  the shutter  release. (Fig.  L4)
5. Repeat the above step after each operation  of the  shutter.
  When  twelve frames have been exposed, continue  advancing  the
   film   until  the  film   is  completely  wound  on  the  take-up  spool.
  Remove  film.
  On  the  right-hand  take-up  spool holder  there  is a  yellow  mark
  which moves when  the crank  is turned.   This mark  is provided for

                                      7
View original page 9
Page 10 · Read text
www.orphancameras.com
   your convenience: align the yellow mark with the white mark on the camera bodv for
   easy removal of fiIm. (Fig. 15)
 6. Red window cover @ can be slid down to ascertain whether or not the camera contains film.
 GAUIION:
When the multiple exposure/filmstopselector @ is set at 'TROLL FILM", the shutter button
@ is operable once only for each numeral, from 1 to 12, appearing in the exposure counter
@.  This automatic locking of the shutler button for prevention of multiple exposure does
 not occur when camera is empty.
When there is no film in the camera, crank operation will not advance exposure counter @.
Consequently,the shutter button cannot be operated even with the shutter cocked and multiple
exposure button @ turned to "ROLL FILM".  However, if the take-up spool remains in, the
same effect as film loading may result, clepqndingon the type of spool.  In such case it  is
not desirable to operate the crank.  Avoid doing so if possible.
TO TAKE IAULTIPLEEXPOSURES

First  bring  the red mark  on the multiple  exposure/filmstop  selector @
to SHEET  or  Multi-exp.   Shtrtter  can be cocked by  pushing down
the shutter cocking  lever @  of  the  lens-shutter  assembly  (Fig.  16).
The procedures  will be the same when the single-exposure attachment
is employed.
                                     8
View original page 10
Page 11 · Read text
www.orphancameras.com
                CHANGING FOCUSING HOOD

                            1. The  focusing hood can be  easily removed  by  loosening  the  lock
                         screw @ and  lifting  up the  rear end  of the assembly.
                             2. To  mount,  match  the groove on the  front  side of the hood  to the
                          two  pins on the body; match  the  rear groove  to the lock screw @
                        and  tighten.  (Fig. LT)
                   PICTUR,ETAKING

With  this camera, ?r  exposure index and  a  parallax  correction  scale  are provided  on  the
ground  glass.  The  indicator  needle starts  to appear  in  the  upper  part  of  the  ground  glass
while the focusing knob  is being operated.  Position of this indicator needle shows the exposure
index and parallax.   In  this  instance, the  parallax  correction  lever @ must  be  set  at  the
index shown on the lens being used.

EXPOSURE INDEX SCALE
As the distance between the lens and film becomes greater, the light value will be lower
provided the aperture is constant.  In this case, the exposure must be increased. I;irst, take
a light meter reading to obtain the exposure and make the correction based on the exposure
index given by the camera.
View original page 11
Page 12 · Read text
www.orphancameras.com
   x                        Figures given on the  left side of the ground glass show exposure
    r.5                        index.    If  the reading  of the scale is 2 with  object  in  focus, this
                                indicates  the  necessity of  doubling  the  exposure.  For  example,
    2                                                        if the exposure meter  calls for  F'8 at 1/60 sec., it  is necessary to
    2.5                       adjust to 1160 at F5.6 or 1/30 sec. at F'8.    3 o
                 PARALTAX CORRECTIONSCALE
                       When  taking  pictures with  the camera held  in hand,  the  portion
  seen above the indicator needle on the ground glass is cut off on the film.  Adjust  the camera
  so that  the subject  will come under  the needle.
  When a tripod or stand is used, the interpositioning of the PARAMENDER  (parallax com-
  pensation mount) will permit you to sight and focus without any par:allax whatsoever.

  PRECAUTIONS
  When  the 65 mm  lens is  to be used, mount  the  accessory parallax
  correction  plate on  the  hood.  Remove  the hood and place  it  with
  the front  side to the back.  The correction plate must be turned over
  also.  Attach  the plate  to the  hood by means  of  two  plate  catches
  and slide lock.   In  this instance,  insert  the edge  of  the  plate  with
  chamfer  into  the plate catches. (Fig. 18)
  Figures on the  left side  of the  correction  plate show  the  exposure
                                   to
/
View original page 12
Page 13 · Read text
www.orphancameras.com
index; lines on the right side are for  parallax.   If  the indicator needle points to  1.5, the
section of picture above the top line will be cut off. When the scale reading is 2, the section
of picture above the second line from the top will be cut  off.  In  this way, this scale can
be used for 2.5 and 3 as correction scale. Parallax correction lever @, in  this case, is set
for 80mm lens.

DISTANCE SCATE AND DEPTH OF FIETD

1. When the exact distance from the camera to the subject must be determined, take a look
   at the distance scale. Hold the camera in shooting position; the scale @ on the right side
   is for 80mm and 65mm lenses and the distance is shown on the scale by the indicator
   needle. On the scale @ on the left side, the value is read in the intersecting points of
  curves representingthe interchangeablelenses and the scale figures on the side of the body.
                                           However, the reading  for 135 mrn lens  is sepa-
                                                      rately provided  rrnder this scale and  it can be
                                                       directly  read on the distance scale @. (Fig. 191
                                                     2. When    it  is necessary  to  check  the  available
                                             depth  of  field, obtain the distance to the subject
                                                     either by referring  to  the distance scale or by
                                                  actual measurement, then make use of the depth
                                                        of  field table.
                                                                       t l                                                                                                                                                                                                                                                                                                II
                                                                                                      I
View original page 13
Page 14 · Read text
www.orphancameras.com
    SINGLE EXPOSUREPHOTOGRAPHY
1. Turn  multiple  exposure/filmstop  selector @  to "SHEET   or  Multi-
   exp".  At  this position the shutter  button can be operated at  will,
   regardless  of the filmwind  crank  and exposure  counter.
2 Remove backlid by pushing inward  the  backlid  hinge  release @,
   lock pivots by turning  up into  the  slots, and  finally  unlock  and
   release backlid catch. The backlid will come off completely. (Fig. 20)
3. Remove the spool from  inside the camera, then attach the special
   single-exposure back, reversing  the removal procedure.   Slide plate
   or cut  film  holder, loaded, into  the grooves of the single-exposure
  back  (Fig. 2r), and secure by means of the  catch  (Fig. 22).  You
   are now ready  for  single picture  photography.

     SYNCHROFLASHPHOTOGRAPHY

1. By attaching  a flashgun or  electronic flash  unit  to  the  accessory
    clip and connecting up with  the synchroflash terminal @, you have
   a handy set-up for synchroflash photography.    It  is convenient  to
  make use of eye-level sighting by .means of  the frame  finder,  or
                              r2
View original page 14
Page 15 · Read text
www.orphancameras.com

   the PORROFLEX.
2- Set the synchroflash M-X  selector @  for  the type  of flash used.  This  acljustment may be
   done after  the shutter  has been cocked.
3. Position "M"  gives the  correct  delayed  shutter  action  for  class M  llashbulbs  (about 20
   milliseconds  to  peak),  permitting  accurate  synchronization   at  all shutterspeeds including
   1i500 second.
4. Position "X"  gives no  time  lag, and  is used in  conjunction  with  electronic  flash  (xenon
   strobo)  for   all  shutterspeeds,  or with  ordinary  flashbulbs  at shutterspeeds  not  exceeding
   l/30 second.
5. When  not using synchroflash, keep selector @  at position  ,,X,,.

              TABTE OF FTASH SYNCHRONIZATION
            --r-!hutter    Speed
 Conloct  rro,r,ii-iu-€c'l   B            tl2     r l t   1 1 8   t / 1 5   I /30     I l60    I lr2s I l2so r /s00
  M   M  closs           a)                                    a)      -        a)               a)
          Electronic Flosh       ^                                           t        a)   o       o    ^
  x   F closs             a)                               a)      r)       r)            a'l     X    X     X

                                                                      a)          X    X     X    X     M closs     o   o       o   o
                          O...will  synchronize        X...will  not svnchronize
                                                               t 3
View original page 15
Page 16 · Read text
www.orphancameras.com
      INTERCI{ANGEABIELENS.SHUTTERASSEMBLIES
                 (MAMIYA-SEKOR    lens with SEIKOSHA-S  shutter)
WIDE-ANGIE (F3.5,  f :65mm,   63-degree picture  angle)
A 6-element, S-group, fully  corrected  anastigmat  with  retrofocus  arrangement,   this  lens  is
unsurpassed  for  brilliance,  sharpness and color  fidelity.   Wide-angle  in  conjunction  with  large
negative size gives extreme  versatility   in press and candid photography.   Outstandingly  suitable
for close range work  such as copying  because lens-to-subject  distance can be as close as
4 inches.
When  a wide angle lens  is used on  this camera,  it  is not necessary to  employ  a  viewlinder
auxiliary mask with  concave lens.
sHoRT FoGAt LENGTH (i?2.8, f :80mm,   50"40' picture angle)
A general-purpose anastigmat  of 5 elements  in 3 groups,  this lens permits close-range photo-
graphy down  to approximately  7 inches between lens and subject.    It  is therefore convenient
for document copying and high  magnification  work.
IONG FOCAT TENGTH (F3.5,  f :105mm,  41-degree picture angle)
All-purpose 4-element, 3-group; this lens  is used for portraiture  and general landscapes, serving
both amateur and commercial  photography.
toNc  FOCAL LENGTH (F4.5,  f :135mm,   33-degree picture  angle)
Ingeniously  designed 4-element, 3-group, fully  corrected anastigmat,  this lens gives reproduc-
 tions  of extreme  naturalness and depth, which cannot be obtained with conventional  twin-lens
                                                                t 4
View original page 16
Page 17 · Read text
www.orphancameras.com
reflex cameras  using  lenses  of. 75mm  focal  length  or  thereabouts.  This   fully  corrected
anastigmat  is eminently  suitable  for  portraiture,  commercial   art  photography,  and  scientific
and industrial  documentation.
TELEPHOTO(F4.5,  f :180mm,   24'30' picture angle)
A 4-element, 3-group, fully  corrected,  this unique  lens, because  of  its  telephoto  design and
construction, does not  differ much  in physical  length from  the 135 millimeter  assembly, and
is particularly  suitable  for stage action photography,  portraiture, and candid shots in situations
where the subject cannot be easily approached.
The conventional  180 mm  lens for  the Model C cannot be mounted on this  camera; use the
180mm lens for Model C33.
             CTOSE-RANGE PHOTOGRAPHY TABTE
                              Minimum Disionce from     Subiect Coveroge                Type  of  Lens                                    Film fo  Subiect          Minimum Distonce
               65 mm                I0Ytao               2)(" x2yrr
               80 mm            T I  L % O          3%"x3%"

              105mm              Lt r0yr6n                     7/ru't x7/u'l

                                              2t  87ra"                              9't xgtl

                                               3t 10y16'l               9)11x9ft'l
View original page 17
Page 18 · Read text
www.orphancameras.com
                   SPECIAL ACCESSORIES
     LENS HOODS   Four types are available





     for 65 mm           for 80 rnm and 105 mm          for 135mm              for 180mm
GAUTION:
1. When attaching the hoods for the 135mm and 180mm lenses, the securing screw side
  should be fitted to the picture-taking (not viewfinding) lens.  Otherwise the dividing partition
   will  obstruct picture-taking.
2. Mount the hood for wide angle lens on the lower lens of the camera by moving side plate
   facing the viewing  lens.  During  the focusing operation, reflection from  the upper side
   plate sometimes enters the viewing lens, depending on the direction of light, affecting the
  image reflected on the focusing glass. When this happens, incline the upper side plate to
   prevent the reflection from entering the upper lens.
                                                                  t 6
View original page 18
Page 19 · Read text
www.orphancameras.com
FIITERS (by TOSHIBA)
Filters of various types are available in three slzes:
      40.5mm diameter screw-in type for the 80mm and 105mm lenses
       46 mm diameter screw-in type for the 135mm lens
     49mm diameter screw-in type for the 65mm and l80mm lenses
Y2, YG, 02 color filters, UV  ultraviolet  filter, and SUNLITE  filter for color film are available.
                         Note:  When attaching filter to the 180mm or 65mm lens, the
                           guard  ring  at  front  extremity  of the barrel must  first be removed
                               by. applying  the  palm  and  turning  counter  clockwise.  Always
                             replace guard  ring  when   filter   is removed.  Be  sure  to  specify
                                       filter  for Model C.

                   PARAMENDER     (Parallax Correction Mount)
                       An  accessory interposed between the camera and tripod  or other
                          mount, the PARAMENDER  permits the lowering of the viewfinding
                             lens down  to level of picture-taking  lens for parallax-free viewing
                            during  focusing  and composing.   Before  releasing  the  shutter,
                              raise the camera  until    it  stops.  The  picture-taking  lens comes
                                into  the  position  of  the  viewfinding  lens and  parallax  is thus
                          completely eliminated.

                                                                                      l 7
View original page 19
Page 20 · Read text
www.orphancameras.com

S!NGLE-EXPOSUREATTACHMENT
 By using the single-exposure back  in place of the standard backlid,
 the special plate and cut  film holders permit the taking  of single-
 frame  negative pictures which  are so useful  in  professional and
 advanced amateur work.  Immediate checking of results is possible.
PORROFTEX
 This  reflex  mirror   attachnr.ent  perrnits  eye-level  viewing  ancl
 focusing by means of an image  in correct  orientation.   Fittecl  in
 the same way as the focusing hood, this viewer  is indispensable
 for candid and press photography.
To mount, remove the hood from the camera, mount the Porroflex
in  its place and tighten  the hood lock screw @.
GRIP I{OLDER
Special grip-form  handle  is particularly  handy  for  steady  holding
of camera during  picture-taking.     It also provides a mount  for the
flash  unit.
SPECIAL LEATHERGADGET BAG
For camera, interchangeable lenses and accessories.
                                r8                            9A50
View original page 20

From the M. Butkus archive. Original publisher and archive notices are retained.
Check the model and edition against your equipment.

PDF verified 2026-10-10.