Home/Butkus archive/Minolta
Light meters

Minolta Auto Meter II User manual

User manual for Minolta Auto Meter II. 23 pages in English. Read the original PDF, download or print a copy without registration.

23 pagesEnglish1.8 MB PDF
Minolta Auto Meter II manual cover
Read the manual Original PDF
Download PDF
Loading your manual…Open PDF directly

Document details

Brand
Minolta
Model / document
Minolta Auto Meter II
Document type
User manual
Language
English
Pages
23
File size
1.8 MB
Category
Light meters
Document date
Not specified in catalog

Search available document text

Find a term, then jump to its page in the original PDF. Image-only pages may not be searchable; check the PDF for exact wording and diagrams.

Page 3 · Read text
Your Minolta Auto Meter  ll  features effortless one-hand operation with a
motorizedmovingscalethat givesinstant,direct readingsautomatically- no manual
djal alignmentor needlereadingnecessary.
    Its high-sensitivitysilicon photo cell and fully transistorizedcircuit yield clear
incident or reflected-lightreadingswith high accuracyover a singleunusuallybroad
rangewithout changeover.
  The light, shock-resistantunit has automatic over- and under-rangewarning,and
accessoriesattach quickly and positivelyby bayonet mount or socketon its rotating
headfor wide versatility.
  For bestresults,it is recommendedthat you readand observeall applicablesections
of this manual.





                 www.butkus.us
View original page 3
Page 6 · Read text
Accessory-receptor jack
ll lu minanceconversiontable
Battery-chambercover
Battery-checkbutton
View original page 6
Page 7 · Read text
B A S I C S





                                                         lnsert a six-volt silver-oxide battery (Ever-
Insertingbattery                                eady No. 544 or equivalent) with plus (+)
1 . Slide  of f  battery-chamber cover as           and minus (-) ends positioned as indicated
   cated.                                             inside the chamber.





                www.butkus.us
View original page 7
Page 8 · Read text
Checking battery
                                                While depressing the unlocked measuring
                                                     button, push the battery-check button.   lf the3. Align and replace cover securely.                                                battery+heck lamp lights, the battery is service-
                                                      able.  lf  not, replace the battery with a fresha a   I  t - r -r ^ \ l
                                                 one.      lf the battery  is not inserted correctly, the
Auto Meter  ll will not operate.
View original page 8
Page 9 · Read text
Use the molded lucite grips to  turn film-
 speed setting disk until the desired film-speed
 graduation line is set to the ASA or DIN scale      The  regular spherical, optional  reflected-
 index. Lines between ASA numbers are for film     light attachment, ND spherical diffusers, and
speedsas follows:                              Spot Mask   ll  are attached and removed as
                                                   follows:
1 2 . o 2 5 . o 5 0 o o                1 0 0  o    o
   16 20     32 40     64 80     125 160
                                                    Align the dot on the rim of the diffuser or2 O O o o 4 O 0 .                       . 8 0 O o o
     250  320      500  ilo      1000 1250    mask with  the receptor-bayonet index; insert
                                                  the bayonet into the mount over the receptor;
1600   o     o  3200  o    o  6400       and turn the diffuser/maskclockwiseas far as it
     2000 2500      4000 5000                  will go (about 1/8 turn) to secureit.





                 www.butkus.us
View original page 9
Page 10 · Read text
To remove
   Turn  the  dif f user/mask counterclockwise
until the dot on  it is aligned with the receptor
bayonet index and lift the diffuser/mask out of
the receptor mount.                              lVleasuring-buttonlock lever
                                                    This has two positions. When the meter is
N O T E                                            not  in  use, the  lever should be turned as
   The optional Viewfinder 10o is attached and     indicated on  it so that the white mark on  its
removed as explained on p. 12: the mini recep-    collar is aligned with the index dot. This locks
tor, as on p. 17.                                   the button so that it cannot be pushed.
                                       When the lever is moved so as to click into
 I ncident/reflected selector                       place in  its other position pointing toward the
   This  is set by grasping its grooved white     receptor head, the button  is unlocked and may
outer surface and turning  it until  it clicks into    be pushed to take readings.
place with  its red index at "lNC."  position for
incident-light readingsor at "REF."  for reflect-   C A U T I O N
ed-light readings. lt  is not intended to be set at      Do not move the lock lever while pushing
any intermediate point between these.             the measuringbutton.

                         Z^\     W               V)
View original page 10
Page 11 · Read text
"T't  (timel scale
   Black figures on this indicate their recipro-
cals as shutter speedsin seconds,e.g., "8000" =
1/8000 sec., "2"  = 112 Sec.,etc. Red  f igures
with appropriate time-unit initials are used to
indicate exposure times of one second or more,
9.9., "4s" = 4 seconds,"8m" = 8 minutes, "Zh"
= 2 hours, etc.

"f l"  (aperture) scale
   The figures on this are lens f-numbers with
intermediatemarks indicating 1/3 stops.
  When the light has been measured,correct
exposure for any time  or aperture value  is
indicated by  the value on  the scale exactly
opposite  it.  For example,  if the indexes for
"125"  on  the  time  scale and  "8"  on  the
aperture scale are exactly aligned, the range of
speed-aperturecombinations indicated that will
yiefd proper exposure includes 1 I2OOOsec. at
f 12,2 sec.at f 164,113Osec.at f l1O,etc., as nrell
as 11125sec.at t18.

                www.butkus.us
View original page 11
Page 12 · Read text
Cine scale                                   speed applicable; e.9., at a frame rate of 32fps
   The figures on this represent frame rates of     with  a sector opening of  45o, the effective
128, 64, 32, 16 and 8 frames per second (fps)    shutter speed would be 11250 sec., and the
and appear above the shutter-speed indications    aperture called for would be found opposite
(for 11250, 11125, 1160, U30 and 1/15 sec.,   "25O" of thg "T"  scale.
respectively) at those rates with a sector open-
ing of  180". The dot  at  the  right ot  "64"
indicates a rate of 48fps; that  right af  "16,"
12tps. The red line between cine.scale figures
"32" and "16" stands for 24fps.
   Metering light  for movie exposure is the
s€rmeas with  still cameras, but for convenience
direct readings may be made from  the lens-
opening values appearing opposite the appli-
cable cine-scale indication, as long  as the
shutter sector opening is 180". For example,
the lens aperture for a frame rate of 24fps with
a 180o shutter sector would be read opposite
the red index indicating the effective speed of
1 /50  sec. For other sector openings, read the
aperture value opposite the effective shutter





                                                                                                *.    .;     ..ii-:.r"   r.'[+.                                                       ;;.;:"d,...       .    .                    -.,....i,i.*!i!.*;at*.".,"                  ,*
View original page 12
Page 13 · Read text
Under /over-rangewarn ing                      changing to one or the other of the spherical
      lf  a red area extends beyond the central   ND  diffusers 1p.'l7l; otherwise, by reducing
index of the under-/over-rangewarning window    subjectillumination or adjustingother exposure
as shown when a reading is taken,  light  is    conditions.
beyond the brightness range of the meter and              lf a red area extends beyond the window
the speed-aperturecombination indicated will    index from the other side as shown, a reading
not  yield correct exposure.  lf  this happens,   below the meter's measuring range is indicated,
conditions should be adjusted so that the index    and exposureconditions should be adjusted,as
falls within the green area. For incident read-   by  increasing light on the subject, until the
ings, this  can  usually be accomplished by    green area extends beyond the index.





                www.butkus.us
View original page 13
Page 14 · Read text
1 . Be sure that the sphericaldiffuser is proper-
     ly attached (p. 6 ) .
2. Set the  applicable f ilm speed (p. 6). Be
   sure the incident lreflected selector (p. 7) is
   set to " lNC."
3. Hold the meter at the subject position (with
   the receptor head turned  if necessary)  in
   such a way  that the spherical dif fuser is
   pointed toward the camera and is receiving
   the same light as the subject.
4. With  the  lever in  its unlocked position
    lp.7l,  push the measuring button  all the
   way  in to take the reading. lf neither over-
   or under-rang  warning is indicated in the
   window (p. 10), read the indicatedexposure
   from the scale desired when the dial stops
   moving. Releasingthe button will prevent
   the d ial  f rom moving with changing I ight
   and preservethe reading.
                                                     Incident readingsmay also be made with the
                                                  optional min i  receptor  (p. 171, 4X  or 8X
                                                spherical N D  diff user (p. 1 7), or  f lat diffuser
                                                        (p. 15) for specialpurposes.
View original page 14
Page 15 · Read text
For ref lected light measurement                   bayonet index as shown, inserting its bayo
   Reflected-light readings are taken with the        net into the receptor mount, and turning
optional  Viewf inder  10"  or   ref lected-light       the ring clockwise as far as it will go. (The
attachment. To use these:                           dot will be out of sight; the Viewf inder 10"
                                               can be removed by turning the ring until the
V i e w f i n d e r 1 O                                       dot  is once more aligned with the index and
1. Attach this accessoryto the meter head by         lifting the bayonet out of the socket.)
   positioning it and the red dot on its grooved    2. Be  sure  the  incident/reflected selector
   attaching ring aligned with  the  receptor-            ( p . 7 )  i s s e t t o " R E F . "





                 www.butkus.us
View original page 15
Page 16 · Read text
Set the applicable film speed.
Rotate the  meter's receptor head to  the
right 180'  or so that the eyepiece is at a
convenient angle for viewing on the front
side of the meter above the exposure scales.
View original page 16
Page 18 · Read text
5. Read the value indicated by the EV-number
                                                    index  as soon as the scale has stopped
1. Attach the flat diffuser to the Auto Meter | |       movtng.
   as indicated on p. 6.                               6. Convert the reading to the desired units by
2. Set  incident/reflected selector to  "lNC."         referring to the table of the back of the
      ( p . 7 ) .                                      meter (e.9.,an indication of EV 10 converts
 3. Set a fitm speed of ASA 100 (p. 6).                  to 2500 luces or 230 foot-candles).
4. With diffuser disk in the desired position
   (normally, parallel and as close as possible
    to the surface where light is to be measur-
   ed), push the measuringbutton.
View original page 18
Page 19 · Read text
t1 6              To determine laghting ratios                        Steps'differenceon    Approx'brightness
                       1. With  the  incident/reflected selector set at                                   ratio of brightness                                                                         reference scare                      "lNC."  (p. 7) and the flat diffuser properly                             source to other
                    attached (p.6),  point   it  directly at the                                                                   0                 1 :                         light source -  viz., continuous lighting units                                                                   1                 2 :                    such as floods or spots, but  not bulb- or                                                                1-1t2               3 :                       electronic-flash equipment  -   to be meas-                                                                   2                 4 :                     ured from the subject position.                                                                   3                 8 :                   2. Push the measuring button and note the                                                                   4                1 6 :                       point indicated by the index on the refer-                                                                   5                3 2 :                   ence-number scale.(There are three indexes,
                   each of which enters the scale range at one     (For example, if the first reading indicates"9"
                   end when another one goes off the other    by the index with no plus number beside it and
                     end.  f f "+1O" or "+2O" appears to the left     the second moves the "*10"  index to "2"  tor a
                         of  the  index, add  this number  to  the    vafue of  10 + 2 =  12, the number of steps
                      indicated value for the correct reading.)        difference is 12  -  9 = 3, and the second light
                   3. Then follow the same procedure to take a    source is approximately  I  times brighter than
                     reading from  the  light source to be conF    the first.)
                      pared.                                               Similarly, the referenceor EV scalecan also
                   4. Find the number of steps difference bet-    be used with the Viewfinder 10" with the meter
                 ween indications on the reference-number   set on  "REF."   to  take readings of  various
                       scale. Then  determine  the  approximate    subject areas. Comparing them by means of the
                       lighting ratio from the following table:          table will yield the subject contrast or bright-
                                                               nessratio between them.                        I
                                                            Lv                            www.butkus.us                                                                                                                                .r'  *
View original page 19
Page 20 · Read text
Minr receptor
                                                     This very small remote receptor is used to
                                         measure  inc ident  conti nu ou s but  not bu I b or
                                                     electronic flash in otherwise inaccessibleposi-
4 X a n d B X s p h e r i c aNl D d i f f u s e r s                   tions.   lt  is especially useful for close-ups and
   Each of these spherical diffusers incorpe     photomacrography. To use this accessory:
rates a  neutral-density element and  is used     1.  Insert the single-prongplug on  its cord all
when  light   is  too  bright  to  be measured       the way into the accessory-receptor jack on
otherwise. With  the 4X  diffuser, the meter's       the receptor head of the Auto Meter ll.
upward range is thus effectively extended by      2. Set the incident/reflected selector to "lNC."
two stops (2 EV); with  the 8X, by 3 EV or             ( p . 7 ) .
th ree stops.                                             3. Metering is done  in the same way as  f or
   Instructions for use of  either ND diffuser       usual incident-light measurements (p. 11).
are  the  same as  for  the  regular spherical      The flexible shaft can be bent and shaped to
diffuser (p. 1 1).                                             facilitate taking readings in many hard-to-
                                                  reach positions.
U9
View original page 20
Page 21 · Read text
Spot mask tor determinirrgenlargingexposure
1. Attach the spot mask to the Auto Meter  ll     4. Project  each  subsequent  similar-quality
    as indicated on p. 6.                             negative on the easel and set the lens to the
2. Set the incident/reflectedselector to "lNC."       same aperture as used for the test enlarge-
      ( p . 7 ) .                               me nt.
3. To  calibrate: Make a satisfactory test en-    5. Place the meter and spot as in step 3 above
   largement by  trial and error without using      and push the measuringbutton.
   the  meter. Then with  all conditions the    6. After  the scales have stopped moving, read
   same, turn on the enlarger again, place the        the  requ ired exposure time  opposite the
   meter on  the  easel with  the mask's spot       aperture+cale f-number  at wh ich the  elr
   toward  the  lens  in  an  area of medium        larger lens is set.
   density in the projected image, and push the        Alternatively,  if you wish to u se the same
   measuring button   until  the  scales have      exposure time as for the test enlargement,
   stopped moving. Next align the enlarger-lens      note the value (e.9., 7 at  tl8  for 8 sec.)
   f-number and the time used to make the test        indicated by  the  index on the reference-
    print  (e.9., tl8  for 8 sec.) on the meter's      number scale in step 3, and proceed with
   expoilre   dial  by  turning  the  film-speed       steps 4 and 5. While keeping the measuring
   settingdisk (p. 6).                                 button  depressed in the  latter, adjust the
                                                   aperture  of  the  enlarger lens  until  the
                                                  reference-number-scaleindex points to the
                                          same value as in step 3 (viz., 7l-. Then leave
                                                      the  enlarger lens set at  that aperture for
                                              exposu re.   lf  the same value cannot  be
                                                  obtained at maximum  or minimum  aper'
                                                            ture, use a higher or lower reference number
                                              and adjust exposure time by one stop for
                                               each step's difference  (t.9.,  at  6, double
                                               exposure time to 15 sec.; at 8, halve it to 4
                                                      sec.).

                www.butkus.us
View original page 21
Page 22 · Read text
TECHNICAL INFORMATION

                Type:  Multi-purpose photoelectric exposure meter with single-rangemotorized dial
              Receptor:  Silicon photo cell                                                                                                                                                                                                     . 1 9
      Measuringmodes:  lncident light with spherical diffuser or optional 4X  or 8x ND diffusers or
                         mini receptor
                        Reflected light with optional Viewfinder 10" attachment!                      llluminance or lighting ratios with optional flat diffuser
                        Enlargingexposure with optional spot mask
           Scale ranges: Film speeds:ASA 6 to 25,000, DIN 9 to 45
                         Apertures: tl1 to tl9O
                      Cine frame rates: 8 to 128 fps (with 180o sector opening)
                     EV: -8  to 25
                      Exposure times: 1/8000 sec.to 2 hrs.
               Circu it:  Transistorized  type  that  compensates for  cell  characteristics and  other
                        conditions and combines with  extended-range motor  unit  for maximum
                      responselinearity
        Power source: One 6v silver-oxide battery, Eveready No. 544 or equivalent
                Other:  Bayonet-type receptor mount on head rotates 300", measuring button  lock,
                        button-lamp type battery checker, EV-to-lux/ft-c conversion table on back of
                        body, separate-receptorjack, over-/under-rangewarning
           Accessories: Included with  unit:  spherical diffuser, neck strap, soft pouch case with
                       drawstrings
                         Available-optionally: Reflected-light attachment (angle of acceptance: Ap-
                         prox.  40"),  Viewfinder 10o (reflected-light attachment with  10o angle of
                       acceptance),flat diffuser, 4X spherical ND diffuser,8X spherical ND diffuser,
                        mini receptor (each common to Minolta Flash Meter ll), Spot Mask ll
                   Size: 4 2 x 6 7  x 1 3 1 m m ( 1 - 5 / 8 x 2 - 5 1 8 x $ 1 / 8   i n . )
               Weight: 27Og (9-112oz.l



                                                                                                                                                                                                                                                                                          *:i.t;*.i*;-'.           .:,,J;iilGi*'
View original page 22
Page 23 · Read text
CARE AND STORAGE


20               Do  not  touch  diffuser  surfaces with  the
                       fingers; keep them clean by using a soft
                    brush on then from time to time.  lf they
                  become soiled, remove loose matter with a
                     blower brush, then wipe gently with a soft
                       cloth.
                 Do not allow solvents or other chemicalsto
                      contact meter or receptor surfaces.
                    Avoid  subjecting your  Auto  Meter   ll  to
                       vibration or shocks.
                  The unit should never be placed or  left in
                     glove compartment or other placesin motor
                     vehicles or elsewhere in which   it may be
                      subject or  to  relatively high temperatures.
                      Further, do not store it in humid places or
                           in corrosive conditions.
                                       lf the Auto Meter  ll  is left unused for more
                     than  a  month,  be  sure  to  remove the
                        battery.
                               r  When the  unit  is to be stored for a long
                       time,  it should ideally by placed in its case                                                                                                                                                            i
                   and sealed in an air-tight container with an
                     appropriate quantity  of  a dehumidifying
                    agent such as silica gel.

                                                  :-;1..  ::r**,,,;:o*",.*              www.butkus.us                                         -*f,aee*r*,S|L-,                                           iI
View original page 23

From the M. Butkus archive. Original publisher and archive notices are retained.
Check the model and edition against your equipment.

PDF verified 2026-10-10.