Page 5 · Read text
Amplif ier
Incident Light Attachnent
for'Amplifier
www.butkus.usView original page 5Page 6 · Read text
Attaching t Turn the adjusting knob 14) of the meter until
the Meter " B " appears in the shutter speed windo* d
" B ". '-fhis enables the meter ,o .o,rpG *ilLT*
shutter rp""d d
tr Attach the meter to the accessory shoe of the.
camera from behind until it stops, make sure that
the gear on the bottom side of the meter engages.
with that of the shutter speed dial.
To detach the meter you musr turn the adjusting,
knob of the meter until the window shows ,. R'1,
this means the shutter speed dial of rhe camera is
also adjusted to t'B " and the meter can be de*
tached from the camera.
l-View original page 6Page 7 · Read text
speed d;al (t) right or left until theHandling I Turn the film
the Meter number opposite the mark A' is the same as the
ASA guide number of the film you are using.
\When an amplifier is attached to the meter, you
should set the ASA number to the mark O in
place of r..
When using the filter over the lens, divide the
ASA number of your film by the filter factor,
then set the attained number to the mark.
For example; if the 6lm speed is ASA 200 and
you use the filter with a fiIter factor of 2,
200-2:lOO therefore,
youwww.butkus.usshould set 100 ro the mark in place of 200.
-2-View original page 7Page 8 · Read text
! \Xzh." you measure the light the needle (g) will
swing. (Refer to " Measuring the Light,, on page
6-8). Observe the position where the needle lines
up with the guide line to f stop nrrmber (7).
The combination of the shutter speed in the window
and f stop number indicated by the needle shows
the correct exposure for the subject. As you turn
the adjusting Lnob, various combinations of shutter
speed aiid f srop number appear. When you choose
one of them, the shutter speed dial of the camera
is already adjusted to the number being shown in
the window, you shuold adjust the diaphragm open-
ing of the camera as indicated by the needle of
the meter.View original page 8Page 9 · Read text
yOUR depends or" of the CHOICE follow- rng two ractors."or
f,Fortakingmovingsubjects,arelativelyfastershutter
speed such as 1/roo or rlzoo sec. is required to stop the 't-),,
subject, so you should get the desirable shutter speedl ,.6ffi,
first, by turning the adjusting knob, then adjtrst the lfrm
diaphragm opening as indicated by the needle. W
,l \ilh"" you need great depth of field in your picrure, a
relatively smaller diaphragm opening (large f stop
numbeiy' such as f IL, 1,6 is required. In such a case
you may previously adjust the diaphragm ring of the
camera to the desired f stop number, then turn the ad-
justing knob until that number comes to the position
indicated by the needle. This adjusts the shutter speed simultaneously as shown in the window which is the cor- M
rect speed for the f stop numberwww.butkus.usyou have adjusted.
4-View original page 9Page 10 · Read text
NOTES
I. The shutter can not work at accurately proportional speed
between graduations, such as between 100 and 200, but
propcrtional f stops are possible
2, If the shutter speed window shows a midway position
between 1 and B, it tells you rhat you should make an
exposure of 2 sec., and in such a case turn the wheel to
B after adjusting the diaphragm scale as indicated by the
needle, then release the shutter for 2 sec. If the window
shows " B ", you should make an exposure of 4 sec.
. The Minolta Meter is coupled with the shutter speed dial
of the camera up to the speed of r/20s sec. For l/466 sec.,
set rhe speed by turning the dial of the camera.
" Flandling the Meter " in page 2 and, 3 is applied
both for reflected light and incident light method.
-5-View original page 10Page 11 · Read text
Measuring the Light
f Reflected light method
This is recommended for ordinary
subjects and lighting conditions.
Remove the incident light atach-
ment (6) if attached on the light
cell (:).
Portraits
\fhen taking a portrait in the sun-
light, bring the light cell (5) of the
meter up.close to the subject's face
(6-12 'inches), and measure both
the light and shadow sides of the
face. An average bei*"en the two
indications will give an accrrrate
reading.
Be sure that the shadow of the
camera does nor fall on the subiect
while measuring. www.butkus.us
-6-View original page 11Page 12 · Read text
.a=-J-j..r.G
Landscapes
To measure the landscape, tilt the
camera downward until the light cell
is facing midway between your feet
and the horizon line. If you should
happen to include the sky in your
measLrrement, the needle will swing
too far.
Inaccessible Subjects
If you are trnable to bring rhe merer
close to a subject (when photograph-
ing a game from an arena, caged
animals or celebrities protected bv
police), measure the liiht refectei
from the palm of your hand. Hold
your palm the normal distance from
the light cell (6-12 inches) and
make your exposlrre according to
this measurement.
-7-View original page 12Page 13 · Read text
I Incident light method
When the subject has extreme contrast of
color or brightness, or the brightness of
backgrounds or settings is very different
from that of the subject. the " Incident
light method " is preferable. These cases
are such as colorful flor,irers, portraits with
the sky for background, or subjects
illuminated by artificial light.
To measure by this method, attach the
incident light.attachment to the light cell.
Face the liglit cell of the meter from the
subject position towards the camera posi-
tion. \When the subject is inaccessible, measurement may be taken at a Proper spot ["e
where there is the same lighting condition
as that of the subject, making sure the light /[\ cell faces the same direction as the above case, i. e. "from the subject to the camera".www.butkus.us/]\
/Jl \View original page 13Page 14 · Read text
[Jnder poor lighting conditions
Amplifier is attachable to the Minolta Meter, which
increases the sensibility of the meter 4 times. In this
case, the ASA number on the 6lm speed dial should
be set against the mark @. E*..it for this, the
handling is the same as instructions on page 2 and 3.
To atach the amplifier, slide it in the shoe of the
fneter until it stops.
To measure by " Incident light methodr', attach each
incident light attachmenr to the light cell of the
meter and to the amplifier respectively..
NOTES
1. 1'he exposure meter should not be subjected to any unnecessary shocks.
2. Try to avoid humidity.
3. Keep your wrist watch away as the meter is magnetic and may damage it.
-9-View original page 14From the M. Butkus archive. Original publisher and archive notices are retained.
Check the model and edition against your equipment.
PDF verified 2026-10-10.