Home/Butkus archive/Minox
Photography reference

Minox guide — part 2 Product booklet

Product booklet for Minox guide — part 2. 31 pages in English. Read the original PDF, download or print a copy without registration.

31 pagesEnglish2.0 MB PDF
Minox guide — part 2 manual cover
Read the manual Original PDF
Download PDF
Loading your manual…Open PDF directly

Document details

Brand
Minox
Model / document
Minox guide — part 2
Document type
Product booklet
Language
English
Pages
31
File size
2.0 MB
Category
Photography reference
Document date
Not specified in catalog

Search available document text

Find a term, then jump to its page in the original PDF. Image-only pages may not be searchable; check the PDF for exact wording and diagrams.

Page 2 · Read text
ffi,,
  t
       OTHERMINOX CAMERAATTACHMENTS

    Minox Meqsuring Choin

         This  is supplied with  the camera to  protect the instrument
                              dropped, and serves as a measure forKf&   against being accidentally
     short distances.
        To attach the chain to the eamera, insert the rectangular plug
      at the end of the chain into the corresponding chain'socket on the
     camera. This socket is normally covered by u spring loaded dust
     cover but will  retract into the camera body on pushing the chain'
     plug into position.
        To  fix the chain plug, use the D-shaped ring attached to  it in
      the manner of a screw driver. Inserting  it into the slot of the plug
      disc, press against the camera chain socket and give the plug a quar'
       ter turn to the right, when it  will be securely fitted to the camera'
        The chain is fitted with beads at distances corresponding ex'
      actly to the shortest distances engraved on the distance scale of
      the camera. With the chain fixed to the camera and held taut the
        first bead (indicating the shortest extension) equals B inches, the
     secondbead 10 inches, the third one 12 inches and the last one IB
      inches.The full length of the chain is 2 feet.

     Minox Tripod Heqd
          This  is a camera cradle with a clamping arm, which carries
      the cable release thread and has at  its end a tripod socket. It  is
      therefore required when using a cable releaseor  if the camera is to
     be mounted on a triPod.
        To  fix the camera to the tripod head make sure that the rec'
      tangular locking lug on the bottom of the clamp is parallel to the
        lorrt",  dimension of the base. Otherwise, turn  the knurled knob
       until the lug is lined up (see page 67) -
         To insert the camera, swing the clamping arm down, towards
      the tripod socket. Slide the camera-with  the chain removed-into

                             65
View original page 2
Page 3 · Read text
the clamp jaws so that all eontrols of the camera face towards the
hinge of the clamping arm. Gently press the camera down on to the       u                                                                                                                                                                                         in
locking lug and turn the knurled locking knob to the right through
one quarter turn. This locks the camera to the base. Now swing the
clamping arm up. This  will Iock the jaws of the clamp and place
the cable release socket over the shutter release button of the cam-
era when the camera is in the open picture-taking position. Insert
the cable release into its socket.
     After each exposure close and open the camera in the usual
manner. The camera need not be removed from  the tripod head
 for  this operation
Minox Pocket Tripod
   When closed, the pocket tripod  is not much larger than a
pencil, but steady enough to support even much heavier cameras
than the Minox.
        It has a built-in ball-and-sockethead. When not in use the legs
are fitted into each other and the hollow center of the innermost
leg housesthe Minox cable release.
    To set up the tripod, unscrew the two small ribbed sections at
the lower end of the tripod. Screw the sections into the threads oI
the tripod  top. To get out the cable release unscrew the small
knurled disc from the thinnest section and pull  it out.
    The swivel top mav be securely locked in any position by turn-
ing the largeo fullr  ribbed section of the tripod. For  extra firm
locking, the section may be turned by inserting a coin in the slit of
the section,using the coin for leverage.
    The Minox pocket tripod may be used on any flat surface, or
braced against a wall, tree, fence, etc. It may also be held against
the shoulder for convenient support of the camera.
    TVheneverlight conditions call for shutter speedsoI l/20 second
or longer, th" Minox  tripod  will assure a steady camera hold and
sharp pictures.
    The Minox pocket tripod, together with the Minox tripod head,

                        66

                        www.orphancameras.com
View original page 3
Page 4 · Read text
lltNox AccEs3oilE3





            Cobb  rcloor  rockol.

             Clomping orm.

              Clcmping icwr.
               Knurlcd locking nut.
               Tripod rockot.
  @Eg

  Thc Minox lripod hcod  ir o comcro crodb
with clomping orm which corrict thc cqbb
rctrorc rockct ond hor  ot  itr ond o  tripod
burh. Mokc rurc thol rhr locking lug on tho
clomp boilom  ic horizonlol bcforc  inrcrting
comero (obovc  fightli  lurn lhc knurlod lock-
ing nul  if rhc lcnr  ir  in rhc wrong porition
(obove center).
   Righr:  fhc   llinox   pockcl  tripod  hor  c
builr-in  bqll-ond-rockcr heod. Whcn  not  in
uro, thc  lcgr orc  ftrtcd inro coch othcr qnd
thc hollow inncrmorl ccnlor hourcr thc cqblc
rcfcorc. For dght: Pockct tripod qr toblo  tri-
pod (top), ot tupporl on your chcrt (ccnlcr),
rtrqdird  on o woll  (boffon).


                                                                                       lcfr: Thc Minox dght
                                                          onglc  flndcr  ir ploccd
                                                             wirh   irr  mirror  ol 45
                                                                              vicw-                  iii:i''iiii:i.i.ii.riiiii.:i.'iiiiiiiiii:ii'i.ii.i:.idcgrccr  to  thr
                                                                  ftndcr ovcr lhr ond of
                                                               thc comero. Cenlcr: Tho
                                                             Alinox   rcfirx    findrr,
                                                      purhod ovcr lhr  findor
                                                           rnd   of  rho  coma?o,
                                                        rhowr q clccr imogo ot
                                                                 woirt  lovcl  for phcte
                                                         grophing  childrrn,  rtc
                                                                                                         lr  door   nol    fif   fio
                                                         mcdrl   !  ilinox.

                         67
View original page 4
Page 5 · Read text
may be conveniently carried in the pocket in a slim leather sheath
case availahle as an accessory.

Minox Reflex Finder
     This shows a brilliant,  clearly defined image and is intended
 for use at  waist-level, particularly  for  photographing children,
low subjects, etc. It may also be used as a right-angle finder for
upright pictures, but in this position it  is suitable only  if reason-
ably fast shutter speedsare used (of l/100 second or faster) as the
camera has to be held in the outstretched hand. where the risk  of
camera shake is much greater.
    The reflex finder  is simply pushed over the finder end of the
Minox camera.

Minox Right-Angle Finder
     This  finder permits taking snapshots at  right  angles to  the
viewing position, for unobserved working. As you photograph, so
to speak, round the corner, the subject remains unaware of the
attention  it receives.
    The right-angle finder consists of a right-angle mirror  in a
light-metal cap which  fits over the finder end of the camera.  It
places the mirror  at 45 degrees to  the viewfinder opening. on
looking  into  the mirror  you can observe the  subject reversed,
left-to-right. The camera lens points at the subject but the photog-
rapher faces at right angles to it.

Minox Belt Cqse
    To be prepared for  picture-taking any time  of the d"y  or
night and under qny lighting condition, carry your Minox and a
flashgun in the convenient leather belt case.
    For the Minox  III  S and Minox  B, cases are available in
brown, black or red leather.
    A special case is available for carrying Minox B and Model
U n/C Flash.

                        68


                        www.orphancameras.com
View original page 5
Page 6 · Read text
DEVEIOPINGAND ENTARGING

    Many Minox users will be quite h"ppy  to get their negatives
developed and enlarged by a photographic dealer who specializes
in Minox service. The manufacturers of the Minox, however, have
also made a special developing tank for processing Minox nega.
tives, and an enlarger designedto give the maximum picture qual-
ity  for  Minox  negatives, as no  ordinary enlarger could.

The Minox Developing Tqnk
     '
   The tank is a daylight loading model and requires no dark-
room. Films may be inserted and completely developed in  full
daylight. A thermometer to check the temperature of processing
rolutions is supplied with the tank.
    While the process of development is an extensive subject
dealt with  in  standard textbooks, the  following  instructions  for
handling the developing tank, together with the set of processing
ehemicals supplied for the Minox,  will  allow even the novice to
develophis Minox film correctly.

Using fhe Minox Developing Tonk

    Before using the tank, make sure it  is perfectly dry. The tank
consists of a body, and a drum with a spiral  film groove, which
screws in and out of the  lid. The drum  is connected to the  lid
(which also has a cassette holder on  its underside), but both
can be lifted  off from the body before or after screwing out the
film drum by turning clock-wise.
  l.  Pull out film leader.
 2. Insert cassettein top part and attach film leader.
 3. Assembly tank.
 4. Screw back drum.
 5. Pour developerin slowly.
 6. Agitate with thermometer.
View original page 6
Page 7 · Read text
7. Pour developer o,rt.
  8. Rinse and fix.
  9. Wash.
10. Unload film.
 ll. Hang up to rlry.
12. Cut up and file.
t.  The  cassette consists of  two chambers: the  feed chamber
    which is plain on both sides, and the take-up chamber which
     carries a round hole  (to engage the transport shaft of the
    camera). Pull the film end out of the t'eed charnber (not the
    take'up rhamber). This end has a punched hole and a smaller
     slot lea<iingaway from  it.
   Turn the top part of the tank upside down (with the drum
    screwed out). Place the cassettein position between the hold-
     ing lug and the drum, push the film end under the spring, and
    button  it to the screw. screw the drum in slightly so that the
    screw properly engages the film  slot, with the film  lying  flat
    and smooth in the groove.
3.  Place the tank body over the top  part, taking care that the
    parts fit together properly.
q.  Invert the tank, and turn the drum counter-clockwiseto screw
        it back into the tank. The end position  is reached when the
    spring'loaded hook on the  lid engages and stops the t6p
    end of the drum.
   slowly pour 2 ounces (53 c.cm.)  of deveroper (preferably
      filter  first)  through  the central opening of  the  tank. The
     liquid  should be  visible in  the wide part  of  the opening.
    Gently tap the tank on the table to disrodge air  bells.
   Place the thermometer  in  the  central opening and  slowly
   move it up and down to make the developer circulate. checl
   and maintain the recommended developer temperature.
    After  the required  time, pour  the developer out. Hold  the
     top of the tank in place with one finger to prevent it from
     sliding out of the tank.

                           70


                        www.orphancameras.com
View original page 7
Page 8 · Read text
b.    f  ill and empty the tank two or three times with clean water
       (at the same temperature as the developer) and pour the
      fixing solution in  (also at the same temperature). l,eave for
     15-20 minutes, then pour out and  fill  the tank with water
     again.
 9.  Put the tank under the tap so that a thin stream of water
      (preferably filtered) runs down the central opening. Wash
       in  this way for 20-30 minutes (at developer temperature).
10. Remove the top of the tank with the drum from the tank. Hold
     the top part in the left hand, with the drum horizontal, and
      turn the drum clockwise. The film winds itself off in a loop.
11.  Pin the film leader to a convenient shelf, and let the whole
       film hang down, with the empty cassette acting as a weight
      at the other end. Dry  in a dust-free room and leave as un-
      disturbed as possible. Use  of a  final  rinse  in  a wetting
      agent-solution minimizes the risk  of water marks and un.
     even drying.
L2.  Cut the film up  into  strips of  l0  negatives and  file  in  the
     negative envelope.

Developing 36-ExposureFilms in the Minox Tqnk
    The Minox Developing Tank  is designed to take the longesl
available Minox  films, i.e. 50 exposures. The instructions supplied
with the tank apply to fullSO-exposureloads.
    The following  instructions apply  only  to 36-exposure films:
     When inserting 36-exposure films into the tank, the spiral
    drum  will  meet resistance after   it  has been turned about
     three-quarters into the tank. This indicates that the film has
    been fully  withdrawn from  the film  cartridge, the  film end
'    remains anchored to the cartridge. Do not turn the drum any
     further into the tank.
      36-exposurefilms require 2 ounces of  all solutions, since the
     spiral drum, being only partly  inserted, does not displace as
   much liquid as when fully turned in.

                                7l
View original page 8
Page 9 · Read text
l,llNOX FltYl PROCES3INO





                                     Dctcription opporitc



      72


www.orphancameras.com
View original page 9
Page 10 · Read text
fiitNox  flul  PRocEtSn{o

   Thc Minox  dcvcloping   tonk  con  bc  loodcd
 ond  tho  film  developed   in  doylighr;   no  dort<-
 room   it  requircd.  Thc rcquence  of  opcrotionr     ir
 cr  followr.
    Opposite  ,op  row:  Pull  out  film  lcodcr  from
 rho  colid  chombcr   of  rhc  cqsrerc    (lcft);  plocc
 corcltc   belwcen  holding  lug ond  drum,  purh
 film ond under  thc prong  ond  bufon    ir to  thc
 rcrcw   (cenler);  ploce  fhe  tonk  drum  ovcr  lhc
 rupporl,  cnrurc  corrccl   fit, ond  scrcw   il counlcr-
 clockwisc  inlo  lhc  ronk  (right).
  ,  Oppositc   middle  row:  Stop whcn  the  tpring
 loodcd  hook  cngogci   on  the   lid   (lefr);  pour
 rlowfy   2   oz. developcr   into  tonk  (cenfer);  in-
 tcrt  lhcrmomofcr   inlo  centrol  opcning,  moving
 ir :lowly  up ond down  lo ogitote  rhe developci
 (right).
   Opposite  botrom  row.. Aftcr  dcveloping   pour
dcvclopcr  out whilc  holding  top po?t of tqnk  in
plqcc  (lefi);  rinse tonk  with  wqter  two  or three
limcr,  lhen  pour   in  fixcr   (center);  ofter   ftxing
wosh,  in  running  woter   (right).  Weiling  ogenl
rnoy bc  u:cd  in  ftnol  rinsc.        .F
  Top   right:  Removc  drum  qnd  top  port   of
tonk.  Whilc  holding  tho  top  port  turn  drum
clockwire  horirontolly,  whereby   film  will  wind
itrelf   off.
  -Centq   rigfrt:  Suspand  film  for  drying   in  c
plocc  frec  from  dust.          HH                                                                   Cut%thc  film up  in-
                                                                              to 5 strips  of  l0  pic.
                                                                           luras  ond  inscrl  into
                                                                  ncaotive    envelopc"
                                                                                   First cut off fhc empty
                                                                         cossettc, thcn  thc  ftrst
                                                                                  slrip  of  l0  negotivct
                                                                which    qrc    inrcrlcd
                                                            emuhion    tide  down
                                                          ond  with  picturc No.
                                                                                                                                 I    in   fron?.   Follow
                                                                           wirh  thc  othcr   stripr,

                      73
View original page 10
Page 11 · Read text
I

     After use, remove the drum  of the tank from  the top  part.
Thoroughly clean and dry  all parts of the tank; do not re'assemble
until completely dry.
Caution: Alter  the d,rum has been turned, into the tank,  it must
 not be turned back. Otherwise the litm may become disengaged
lrom the d,rum and causescratcheson the emulsion.

Minox Negotive EnveloPe
    As  it  is absolutely essential that the Minox negatives are not
touched by hand or open to  dust,  dirt,  etc., a special negative
envelope has been designed.  It  consists of  a  stifi  transparent
plastic envelope to accept 5 strips each of  l0  negatives. You can
therefore file a complete film on one sheet. The  strips between
the,negatives are numbered from 1 to 50, so that each negative
can be clearly identified
     This SQ-frame transparent envelope is  supplied  in  a  card-
 board cover with  space for   full  data  for  each negative. After
 processing, each Minox  film should immediately be cut up  into
 strips of ten frames and placed into the negative envelope. Other'
 wise scratches,marks, etc., are simply unavoidable. The best way
 of doing that  is to start by cutting  off the empty cassette at the
 first frame. Then cut  ofi the  first ten frames and slide the strip
 +mulsion   side down and with No.  I  leading-into   the first sec'
 tion  of the negative envelope. Proceed with succeeding strips in
 the same way. All  the negatives are then in  their  correct order,
 and correctly orientated.
 Minox Film Viewing Mognifier
     This shows the negative at approximately the same apparent
 size as a  standard 3Vz X  4V2 inches enlargement at normal
 viewing distance. The viewing magnifier is pushed over the trans'
 parent negative envelope (see above) so that the negative does
 not need to be removed from  the envelope for  inspection.
    The negative is framed by a metal mask  in  the magnifier
 holder to prevent distracting  side-light. A  cut'out  in  the frame
 shows also the number  of  the negative being examined.

                       74

                         www.orphancameras.com
View original page 11
Page 12 · Read text
The magnifier may be removed from  its frame to be used for
 other purpoEes or  to be  inserted  into  the frame  of  the  trans.
 parency viewer and cutter (page 29).

 Minor Devcloping Ghcmicalr Kit
    A special set of chemicals is available for the development of
 Minox  films.  It consists of 15 bags of each of the two deu"loper
components required,  15 bags of  fixer and 15 bags of  wetting
 agent. The bags are of thermoplastic  foil and  air-tijht      well as
 water'proof. Each developer set makes z ounces (s3  ",c.cm.)  of
 solution, that  ie the correct amount required  for  the Minor  tanlc.
    The  developer  its€lf  is  a  fine  grain  developer,  producing _
 almost grainlese results, without  requiring  extra  exposure.
       makg up the developer dissolve the contents of one bag of
developer eubstance A completely in about  I ounce (30 c.cm.)- of
water at not more than 100  F. Add part B slowly under constant
€tirring.  when  everything  is  dissolved completely,   fill  up  to 2
ounces (53 c.cm.).
    The development time for slow films is l0 minutes, for medium
speed and fast films 14 rninutes, always at 65.6?.  F. Keep to this
temperature.
    Prepare the fixer by dissolving the contents of a bag of fixing
salt, which you  will  find  in the lower part  of the packirrg, in   i
ounces (53 c.cm.) of water.
     'This         developer is unsuitable for  the copying film,  for which
the conventional contrasty developers should be employed.
    To prevent streaks and drying spots it  is advisable to soak the
film  after the final wash for  l-2 minutes in a wetting agent. To
make up this bath dissolve the contents of the bag marked .,wet-
ting agent" in  I quart of water.

Enlorging Minor  Negotives
    Enlargement of the negatives follows the procedure outlined
in any standard textbooks on the subject. Extra care is, however,

                        75
View original page 12
Page 13 · Read text
necessaryto deal with  the small negatives and to avoid spots.
scratchesand other defects.
   A  special Minox enlarger has been designed for enlarging
Minox negativesto retain the highest possible definition by allow'
ing for the curvature given to the films in the camera. The liberal
dimensions adopted in conjunction with use of an inclined column
ensure vibration-free work and permit the lens'mount to be adjusted
with maximum accuracY.

The Minox Enlorger
    The baseboard permits enlargementsup to l0 X 14 inches to
be made on  it. For even bigger enlargements the image may be
 projected horizontally onto a  wall by  using a  surface-silvered
 mirror. The baseboard is covered with a rubber top  to  avoid
 unintentional movementof the masking frame.
    The light source is a 6 volt 6 amp. filament lamp. It receives
 its current via the transformer which is housed in the base of the
 instrument. Before connecting the enlarger (to A.C. current supply
 only) the line voltage should be checked. The instrument is prop'
 erly set if one core of the cable coming from the switch is con'
 nected to the clamping screw of the transformer corresponding
 to the main voltage of the supply available. \
    The lamp has a bayongt socket and is inserted in such a way
 that the transverse filament within  the bulb  points downwards
 towards the baseplate.
    A dimming switch is built-in at the right  of the foot of the
 column. This can be set to bright  or dimmed illumination. Use
 bright light for focusing.
    The lamphouse, together with  the  film  stage and lens, is
 adjustable in height on the column by pressing the height adjust-
 ment lever inwards. The lamphouse can be opened by pressing
 the button near the top rim on the back of the lower part of the
 housing. To close it place the front hole over the corresponding
 retaining pin, pull down the top towards the back, depressing the
 button, and let the top click into place.
     The  lilrn  gui.d,e keeps the negative in  the correct  position
 during the enlarging process. It consists of two metal masks. To

                          76

                        www.orphancameras.com
View original page 13
Page 14 · Read text
obtain the best possible definition the masks are curved. To  inter.
 change the upper backing plateo lift  the lever at the right  of the
 lens. In  this position the pressure on the film  is released and the
backing plate can be pulled out. To insert the backing plate push it
 into position from the front.
    To  insert. and, align the negatiae  strip the top backing  plate
 has to be in the lifted position to clear the film. After positioning
 hold the film  in place with both thumbs and index fingers, at the
 same time using the middle finger of the right hand to press the
                                                                             '(to lever down  into  its  horizontal  position.  Lift  the lever      take
 off back plate pressure) when moving the film  to the next frame.
 This  is best done by holding   it between the middle and fourth
 fingers of the right hand.
                                                          'lowering    The  size ol  enlnrgement  is  set by  raising  or            the
 lamphouse. Simply  depress the  lever on the  sliding lamphouse
 arm, and move the  latter up  or down. Release the lever when
 the lamphouseis in the required position.
    To locus thc lens rotate  its lower knurled  collar. The lens is
 of  highest optical  quality,  and  is  coated. In  conjunction  with
-the curved negative carrier   it  will  yield perfect definition.
    A red filter, sometimes used to position the enlarging paper
while the light  is switched on, is available as an'extra.  It  is simply
clamped on to the rib of the tubular guide on the enlarger.
     For  cleaning, the lens can be detached and the lower  film
guide mask removed by turning  the upper knurled lens ring  to
the left, thereby unlocking  it.
    The  tilting  lamphouse facilitates  getting  at the condenser or
the negative in order to clean them.
    To clean the lamphouse, .open it as described above. The lens
should be cleaned only with a piece of fluffless well washed linen
wrapped round  a  matchstick, or  special lens tissue. When  ne-
inserting the lens take care that  the cutouts on  the  rear  lens
barrel engage the pin  situated on the side of the film  guide next
to the column.
    A push-button switch  in the cable switehes the enlarger lamp
on and ofi for exposing the print.

                         77
View original page 14
Page 16 · Read text
Hiding  scratches in negatiaes. The optical system is designed
 to ensure perfect  definition  over  the  entire negative area, but
 is soft enough to hide slight negative defects.
    To enlarge badly scratched or  otherwise damaged negatives
 without making these faults too pronounced a built-in  opal glass
may be swung into  place. The exposure time  will  be somewhat
 increased and the contrast slightly lowered. This  latter fact  is an
advantage for  contrasty negatives; for  normal  ones  it  can be
compensated for by using a slightly more contrasty paper.
     Direct  current.  If  only D.C.  is  available, the enlarger  witl
operate via a series-resistance,which  is available for various volt-
ages from 110 to 220 volts. No traneformer is required.
    A special enlarging easel with interchangeable masks is  avail-
able for use with the Minox  enlarger. The frame accepts any of
the four masks corresponding to  the usual sizes: 2t/2 X  3y2,
3y4 X 4y2 and 4 X 5 in. The masks can be inserted or changed
in a matter of a few seconds.
    The frame  is automatically fixed on the baseboard in any
required position.
Tronsporencies
     Color  films  yield  transparencies instead  of  negatives, and
these may be viewed in a suitable viewer or   projected on a screen.
     Color enlargements are  available from  local  photofinishers,
or  you may make these yourself on Anscochrome Printon  or
Kodak EktachromePaper (Type R.).
Minox Trcnspcrency Viewer qnd Cutter
    The strips of color transparencies (or black-and white)  can,
of course, be viewed with the negative viewer and magnifier (p"g.
74), bat the transparencies have to be cut into single frames  if
they are to be mounted into the Minox transparency frames to be
used in a projector.
    For  this reason a special viewer has been designed which
has in  addition a  built-in  cutting template and knife. When the
transparency is correctly positioned in the magnifier, a slight pres-
sure with the thumb on the knife blade cuts the transparency out of

                       79
View original page 16
Page 17 · Read text
. P
the strip. It seemsneedlessto state that for viewing transparencies
they should remain in the negative envelope,while for cutting they
have to be removed. The iut transparency has the correct dimen'
sions for fitting into the Minox transparency frame (see below) '
    The slip-in magnifier is the same as used for  the negative
viewer and can therefore be used for both devices'





                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        IMounting Trcnsporencies
     Special 3 X 3 cm. transparency frames are available to mount
 the Minox  I X  fI mm. transparenciesfor projection in the Minox
 slide projector (seepage 83).
    Mount the slides in a room free frorn flying dust'
    The cover glassessupplied with the Minox slide frames have
 been carefully cleaned before wrapping. They should therefore
 remain in their original packing until needed and rernaining glasses
 carefully rewrapped. In  this way you can save the arduous work
 of cleaning cover glasses.
     For accurate and convenient cutting of the transparenciesthe
 viewer and cutter (seepage 79) should be used.
    To mount the transparency irlto the frame proceed as follows:
  l.  Place metal frame with index window on table with index
    window away from you, the four  (ott latest versions, two)
     tongues facing uP.
 2.  Insert a paper tnask.
 3.  Insert one cover glass (hold at edges,rnly)
 ,1,. Insert a netal rnask with indented frarne facirrg up; position
    mask for vertical or horizontaltransparency'
 5.  Place the transparency into the frame with the dull side up,
     so that the picture is upside dowtr.
 6.  Insert the second cover glass.
    t .   Place the  slotted metal  fratne  over  the tongues  of  the lower
      frame.
 B. Bend  the tongues towards  the  center  of  the frame  with  the
     end  of  a  pencil  or  similar  tool;  smooth  the tongues  flat.
  9.  Write  the   file  or  reference  nunrber   in  the  fihn  window.              iJ
           For  correct projection,  the slide is placed in the projector

                         80
                          www.orphancameras.com
View original page 17
Page 18 · Read text
MAKING MINOX STIDES





  Above:  fhe  Minox  lrdn3Poroncy  vicwer  ond  cul'
r",  p"t-it.    inspeclion  of  siripr  of  tolor  ond  block'
snd-whitc-      lronsporenciel  qnd  hor  o  cutting  tem'
;il"      or,l   lnit"    built   in'  Slight  pressurc  on  lhc
["-"if.     ."tt   lhe lronsporency  oul  of  the  rtrip'
                                              fromer                                lronrporency                          cm'                  X  3                  3   Right:-o"oilolleSpeciol                                                                                            I  mm'                                       8  X     I                               Minox'                             lhe                 mounl                    looro
i*tp"t"n.ics        for  proicction   in- rhq  lllinox   pro'
 il;          ii"   ordcr  of  orrcmbly   of  thc -fromc   is: A
 L"i".'"'lt"-"    with  four  longue3 uP  in front  of  you'
 i:;;-;;per        mosk,  c  rop  w.iih  cover  sloss' D
 1"""t   -rt[    i.tol    -o'L,   indented frome  up' E ploce
 ;;p;;:il           (dutl  ridc  up,  picturc  upside  down)
 i"i"-ifr.   fromc,  F rop  with  rccond  cover  glosr' G                                              fromc                                             of  lower                            tonguer                          tvcr               fromc olocot"ti;    tloilod                                                    only                                         hcvc                                 lorest frome:                      Thc                              in'              ;Jnsr;,
 ;;      ;";"i     Jna  rlotr  inrlcod   of  four'  os shown'
    Sclow:  fhe  durt  proof  lronrPoro-nl  Plortic  box
 h.iJ;-;d   mountcd  tronrporencier'  An  index  cord'
 plt",+d  on  toP Gqn bt  ieod  without  opening  the
 box.





                                 8l
View original page 18
Page 19 · Read text
rHE mtNox ?toJEctot


    Righr: Thc itinox   rlidc
  proioclor rnodcl 30  it  rhc
  nort  rqlirfying  mconr  of
 rhowing color (ond block-
 cnd-whirr)   llinox   ?ronr-
  porcncicr.

           ?.=,





    hfi:  Thr lenr  ir  lcl  in s focuring                                 -mounl in front  of rhc horizonlol 4idr  ehongor. ccntq:       -Thc             fonrporcncy    ir  inrcrrid  ro  thot  itr numbrr   ir in   rhr  rop- or,a-lo1i
 to thc bcct<. Righr; An odiurrncnr  knob pcrmirr  rihing  ,p    i,  down  io;iig;-rh. tcnran pictun.





_   lolt: rho hmp houro ir oprnrd on prordng rho blsck button bdow  thr  trnr.
crrtrr:  lhr lomp odiulmcnt rcrow ollowr ro-ining -rcfo,rhr lornp. lugir,  r'io-;;rtt;;
ccta p?ct clr tho inrtrumrnl frem durt ond ollowr       rcry, lrcnrporl.

                                 8'

                           www.orphancameras.com
View original page 19
Page 20 · Read text
slide changer with the inclex window on top and facing to
         the rear of the Projector'
          Removeany dust from the t;over glass with a camel'shair
         brush; fingerprint. o, other smudgesmay be removed with a
        chamois cloth, lens tissue or other lintless, solt material.
            Minox transparency mounts are now available with metal
       masks in the r0 x 14 mm. size to incorporate 16 mm. slides'
     Minox TronsporencY Storoge Box
         For convenient and dustproof storage of the mounted tratts'
     parenciesa transparent plastic box has been designed to accept
     50 Minox  trar,rpar"rrci"r. An  index card  for  full  data of each
     transparencyis providbd, which-if  placed on top inside the box
     -can be read from outside.

     Minox Slide Proiector Model 3O
        T h i s p r o j e c t o r h a s b e e n d e s i g n e d f o r t h e p r o j e c t i o n o f B X . l l
t\*  mm. Minox transparencies.It  is also suitable for other sub'mini'
      ature transparenciesup to f5 X 15 mm'
                  I t h a s a c o a t e d l e n s , l 0 0 w a t t p r e { o c u s t y p e l a m p a n d a
      sphericalcondenserto yield a sharp and bright image'
         Always set up the projector first and switch it on a{terwards'
     when the lamp  is switched on, the projector must not be tilted
       or shaken. When setting up the projector' make sure that  air
     has free accessto it from below'
         The lens is focused by  turning   its  milled mount  until  the
  *    picture on the screen is sharp' For cleaning purposes' th-" I,ens
        -u,  be turned counter.clockwiseas far aS it  will go and then
       pulled out towards the  front. The lens tube, together with  the
       slide carrier, is also removable. Press it  into the projector, and
       after a turn to the left, pull it out towards the front.
         The slide changer is of the push-through shuttle design' Draw
            it out at one side as far as it will go, insert the transparencyframe
       with the oval white numbered window at the top and facing the
      back of the projector. The slide holder is then pushed to the other
       side to  its stop. The transparency will now be in the light beam r
                             83
g
View original page 20
Page 22 · Read text
When inserting the lamp  it must be adjusted for even  il'
        lumination of the picture area. To do this, open the  lid  of the
       lamphouse,place a piece of white cardboard about 12-15 inches
         in  front of the projector and, without inserting a transparency'
        switch on the tight. Manipulate the adjusting screw behind the#         interior black lamphouse in such a way that the bright square
          field on the card becomes as evenly illurninated and as bright
       as can be obtained.;&lm
         A  leather case in which the projector can be safely trans'
        ported is supplied with  the Minox  Slide Projector 30.  It  also
        protectsthe projector against dust.
- * .
      The Minomot
                                                                  projector dliif;     The Minomat is the newest and brightest automatic
          built exclusively for the projection of Minox glass-mountedslides'
            This ultra'compact projector measuresgy4" X By2" X  6"'$              clear, brilliant pictures are projected by 35mm | 1.6 Minolux
         projection lens, and fan-cooled150-wattlamp'
             Small, light Remote Control  Unit  allows completely auto'
        matic control of the Minomat at distances up to 32 feet (f6   ft'
        cable and 16 ft. extensioncord).
            Also available is wireless remote control  unit. Master unit
        has three push-buttons for  slide changes and two-way focusing'
           Remote control cord and wireless ultrasonic control can be
        combined with automatic slide timer adjustable from 5'45 seconds.
             Custom-fitted carry-all case, 15" X I0V2" X 63/+", accommo'
        dates all Minomat accessories-power cord, remote control unit,
         automatic timing device, intermediate plug and 3 slide rnagazines'
           Minomat  slide magazine holds 36 metal and glass Minox
         slides in numbered slots. Minox 30mm X 30mm transparency
        frames with B X   fl mm masks for Minox pictures are currently   **
          available; 10 x 14 mm masks for projecting transparenciestakert
          with  other ultra-miniature cameras will  also be available'   Kfrt:i
{rf          The Minomat projects slides three times larger than other
         miniature projectors at the same projector'to'screen distances.

                              85
View original page 22
Page 23 · Read text
SUBJECTSIN FRONTOF THE MINOX


 Animolr-Our   Pets
   We only need to watch t}em at play or in repose to get not one,
 but a whole series of pictures. The camera is best pre-set for zone
 focusing (p. 2B). A low viewpoint  is essential, othelwise we shall
 dqvarf our subject. To get close-up heads, it  is best to pre-set the                                              I.
 Minox  at a fixed distanee, attract the attention and expose just
 as the head comes into range. In  the Zoo animals behind bars           {
and mesh netting can be photographed by putting the lens right
 into the space between the bars or netting to avoid their appear.
ance in the picture. The permission and cooperation  of. Zoo au.
 thorities should of course be secured before placing a camera
between the bars of a cage. The chief problem will be the usually
 distracting and ugly background. By choosing side lighting we
can eliminate background detail. At the same time the animal will                  L
receive satisfactory modeling and  will  "stand  out"  boldly. One
should rnake sure of generous exposure to secure good rendering           L
of fur, skin or feathers. Normal speed material without a filter  will
serve in most cases.

Architecture

    The typical  "picture-postcard" view can be bought but not
your own personal architectural discovery. So concentrate on de-                   :a-
tail. The Minox has to be held straight, otherwise everything will
appear distorted and toppling  over.  (Still,  intentionally  disiorted
views may be effective. For these you must go quite close to the
building and take  it  at a sharp angle from a low viewpoint.|   If
you must get a lot into the picture, it  is essential to stand well back
from the building. With  all architecture direct front  light  is bound
to give a  flato uninteresting photograph with  little  detail. Front.
side lighting  is almost essential to liven up the subject. Extreme
side lighting may produce disturbingly strong shadows casting across
important lines and shapes.                                                              {

                                                                                                                                                                            -.t
                        86


                          www.orphancameras.com
View original page 23

From the M. Butkus archive. Original publisher and archive notices are retained.
Check the model and edition against your equipment.

PDF verified 2026-10-10.