Home/Butkus archive/Nikon
Film cameras

Nikon F2S Photomic Finder DP-2 BOOKLET Product booklet

Product booklet for Nikon F2S Photomic Finder DP-2 BOOKLET. 32 pages in English. Read the original PDF, download or print a copy without registration.

32 pagesEnglish1.7 MB PDF
Nikon F2S Photomic Finder DP-2 BOOKLET manual cover
Read the manual Original PDF
Download PDF
Loading your manual…Open PDF directly

Document details

Brand
Nikon
Model / document
Nikon F2S Photomic Finder DP-2 BOOKLET
Document type
Product booklet
Language
English
Pages
32
File size
1.7 MB
Category
Film cameras
Document date
Not specified in catalog

Search available document text

Find a term, then jump to its page in the original PDF. Image-only pages may not be searchable; check the PDF for exact wording and diagrams.

Page 3 · Read text
NOMENCI-ATURE





Maxi mu m aperture indicator



Meter coupling pin





                            www.orphancameras.com
View original page 3
Page 4 · Read text
Shutter-speedselector

             Ready-light

     Shutter-speedindex
      Shutter speedscale
  (for extra-long exposure)

      Shutter-speedscale

     Viewfindereyepiece

       Ready-light contact

         Meter window

      Finder releaselever

ASA film-speedindex ring

         Film-speedscale
View original page 4
Page 5 · Read text
CONTENTS
      Foreword
      Attaching the Photomic Finder               6
       S h utter-speedcoupling                    7
        Lens-aperture cou pling                    8
      Maximum aperture indicator               9
        Setting the film speed .                   1 0
            I n s t a l l i n gt h e B a t t e r i e s. .  . .                 1 1
      C h e c k i n gt h e b a t t e r i e s. . .   .                1 2
     ExposureMeasurement
          (fu I l-aperturemethod)                            't3
       Switchingthe meter on  . .                 1 3
       Determiningexposure                   1 4
       Choice of shutter-speed/lens-aperture
         combinations . . .                      1 6
       Extreme low-l ight metering               1 7
       Meteringrange.                         1 8                                                               't9       Unusual light situations. .
     ExposureMeasurement:SpecialCases .      22
       Stop-down exposuremeasurement . . .      2 2
       Exposure correction for special
         lens/focusing-screencombinations . . . . . . . 24
       Repro-copying,slide-copyingand
         p h o t o m i c r o g r a p h y                               . . . . 2 6
     Care and Handling                                                . . 28
     F e a t u r e s / S p e c i f i c a t i o n s                               . . . 3 0
www.orphancameras.comT h e N i k o n W a r r a n t y                                . . . . . . 3 ' l
View original page 5
Page 6 · Read text
FOREWORD

Designed to  fit  any Nikon F2 camera, the Pho-
tomic Finder DP-2 incorporatesa precise center-
weighted CdS exposure metering system coupled
to  the lens-aperture and shutter-speed controls.
lnstead of the usual meter needle, light-emitting
diodes in the viewfinder glow bright red in two
signal lights to  indicate correct exposure. The
signal lights are also visible on top of the finder.
Besidesproviding easy-to-seemetering information
even  in  poor  light, the  finder extends meter
sensitivity down to EV -2  (8 secondsat f 11.4 with
a n A S A 1 0 0  f i l m ) .  I n c o m b i n a t i o nw i t h  t h e E E
Aperture Control Attachment DS-1 accessory,the
Photomic Finder DP-2 provides the Nikon F2
camera with automatic exposure meteringcontrol.
View original page 6
Page 7 · Read text
ATTACHING THE PHOTOMIC FINDER

   To attach the finder to the camera mounted with a lens,
    first set the lensaperturediaphragmat any nu mber smaller
   than f/5.6, center the meter coupling pin and loosely
   place the finder in position. Pressthe finder down gently
   u n t i l  i t c l i c k s i n t o p l a c e a n d  t h e  t w o c l a m p ss e t t l e i n t o
   p o s i t i o n T. h e n t u r n t h e l e n sa p e r t u r er i n g t o  t h e m i n i m u m
   aperture setting until the meter coupling pin and lens
   c o u p l i n gp r o n g a r e l i n k e d .
   Mounting the finder on the camerabody without a lens is
   s i m p l e . J u s t s e t  t h e   f i n d e r   i n  p o s i t i o n a n d p r e s s i t
   d o w n w a r dg e n t l y u n t i l i t c l i c k si n t o p l a c e .
   To remove the finder, depressthe base of finder release
   lever and turn the lever downward, then pressthe finder
   releasebutton on the back of the camera.The finder will
  come looseand can be lifted out.





www.orphancameras.com
View original page 7
Page 8 · Read text
S h u t t e r - S p e e dC o u p l i n g
When the Photomic finder is attached to the camera,the
shutter-speeddial on the camera is inaccessible.There-
fore, an auxiliary shutter-speedscale is provided on the
finder. With the finder in place, rock the shutter-speed
selectoruntil  it engagesthe dial on the camera and the
two rotate together.
View original page 8
Page 9 · Read text
T h e P h o t o m i c f i n d e r  t a k e s a d v a n t a g eo f  t h e a u t o m a t i c
    d i a p h r a g mf e a t u r eo f N i k k o r A u t o  l e n s e st o m e a s u r el i g h t
   w i t h  t h e  l e n s w i d e o p e n . F u l l - a p e r t u r em e t e r i n gg i v e sa
   b r i g h t , c l e a r f i n d e r  i m a g e f o r v i e w i n g a n d f o c u s i n ga n d
  m i n i m i z e st h e e f f e c t o f  l i g h t e n t e r i n gt h e v i e w f i n d e rf r o m
   the eyepiece.
       I n o r d e r t o m e a s u r ee x p o s u r ea t  f u l l a p e r t u r ew i t h  l e n s e s
   h a v i n g d i f f e r e n t m a x i m u m a p e r t u r e s t, h e m e t e r m u s t b e
    c o u p l e d w i t h  t h e m a x i m u m a p e r t u r eo f  t h e  l e n s i n u s e .





www.orphancameras.com
View original page 9
Page 10 · Read text
This is done each time the lens is attached or changedas
follows:
Position the lens in the camera's bayonet mount so that
the indicator dots on the lens and the camera body are
aligned.Grasp the lens by the white milled ring and twist
it counterclockwiseuntil  it clicks into place. Turn the
aperture ring all the way to the minimum aperturesetting
(largest f/number), then  all the way  in the opposite
direction.This step automaticallyfits the coupling pin of
the Photomic finder into the coupling prong on the lens
and adjuststhe maximum apertureof the lens.

M a x i m u m A p e r t u r e   l r r d i c a t o r
The above adiustment can. be verified by checking the
maximum aperture indicator in  the window on  the
Photomic finder. The scale has a range from   f l'1.2 to
f 15.6.For example,if the 24 mm  f 12.8 lens is mounted on
the camera,2.8 should appearin the window.
                                                               lm Apcnurc scrrc   $.
                                         4._.u45
                 W*                              2
                                        t4
                                        t2
View original page 10
Page 11 · Read text
10 ATTACHING THE PHOTOMIC FINDER-continued

                              S e t t i n g t h e F i l m S p e e d
                              The exposure meter of  the Photomic finder must be
                                  adjusted for the speed (ASA number) of the film in use.
                                               Lift up the milled ring around the film-speeddial and turn
                                                                it so that the film speed appearsopposite the red arrow.
                              The film-speeddial coversa range from ASA 12 to 6400
                                     with two dots betweeneach pair of numericalsettingsfor
                                                                                          i n t e r m e d i a t ev a l u e s s, u c ha s A S A 6 4 , 8 0 , 1 2 5 , e t c .





                             www.orphancameras.com
View original page 11
Page 12 · Read text
INSTALLINGTHE BATTERIES                                           1 1

T w o 1 . 5 V s i l v e r - o x i d eb a t t e r i e sa r e s u p p l i e d w i t h  t h e
P h o t o m i c f i n d e r . T h e y m u s t b e  i n s t a l l e di n  t h e b a t t e r y
chamber on the Nikon F2 camera baseplatebefore the
m e t e rc i r c u i t w i l l o p e r a t e .
To installthe batteries,twist the baseplatecap with a coin
or similar object to remove it and drop the batteriesinto
the chamber. Make sure that the plus (+) side faces out.
Then replacethe cap.

C a u t i o n : R e m o v e t h e b a t t e r i e sw h e n t h e c a m e r a i s n o t
usedfor long periods.
A t b e l o w - f r e e z i n tge m p e r a t u r e st,h e b a t t e r i e sm a y m a l -
f u n c t i o n o r c e a s et o o p e r a t e u n t i l  t h e  t e m p e r a t u r er i s e s
again. Be careful not to expose them to severecold for
l o n g p e r i o d s .
View original page 12
Page 13 · Read text
1 2    I N S T A L L I N CT H E B A T T E R I E- Sc o n t i n u e d

                            C h e c k i n g t h e B a t t e r i c s
                                       Pull out the film-advancelever to uncover the red dot on
                                     top  of  the camera and watch the signal lights in the
                                   viewfinder or on top of the finder. lf either of the two
                                        lights glows with a bright red light, the batteriesare in
                               good condition. lf not, they need to be replaced.





                             www.orphancameras.com
View original page 13
Page 14 · Read text
EXPOSUREMEASUREMENT(full-aperturemethod)
The exposure meter of the Photomic finder features a
center-weightedthru-the-lensmetering system coupled to
the shutter speed and aperture controls. The meter reads
the  light over the entire focusing screen but favors a
central area. This allows you to make precise reading of
the selectedsubiect area.

S w i t c h i n g t h e M e t e r O n
The film-advance lever also servesas an on-off switch for
the exposure meter. To turn the meter on, pull out the
lever just enough to uncover the red dot on top of the
camera.When the meter is not in use, pressthe lever flush
againstthe camera body to avoid battery drain.
                                                                                                                          I

                                                                                                       )
View original page 14
Page 15 · Read text
14  EXPOSUREMEASUREMENT-continued
                           DeterminingExposure
                                The Photomic finder has two signal lights in the view-
                                          finder, one with the plus (+) sign for overexposure,the
                                      other  with  the minus  (-)  sign for underexposure. To
                                   determine the correct exposure, first switch on the meter
                                and either of the two signal lights glows. Then turn the
                                    aperture ring and/or shutter-speed selector until  both
                                     signallightsglow.
                               The signal lights are arrow-shapedso that by the direction
                                     the arrows point you  will know  at a glance which
                                 exposure control, the aperture ring or the shutter-speed
                                        selector, is to be rotated for correct exposure. For added
                                   convenience, the actual shutter speed and the aperture
                                   selectedalso appear in the viewfinder.Either the aperture
                                         ring  or  the  shutter-speed selector (except for speeds
                                  slower than 1/80 second) permits reliable intermediate
                                       settings for  more  precise exposure of  less than one
                                   f/number. The signal lights also appear on top  of the
                                      finder for conveniencewhen the camera is held at waist
                                       level or mounted on a tripod. ln low light, the two signal
                                         lights may light up at "B"  setting on the shutter-speed
                                     scale.lf so, correct exposuretime is 2 seconds.

                             www.orphancameras.com
View original page 15
Page 17 · Read text
EXPOSUREMEASUREMENT-continued

                      Choiceof Shutter-Speed/Lens-Aperture
                      Combinations
                           The amount of light reaching the film  is determined by a
                              combination of lens aperture and shutter speed.Since the
                             two are interrelated, different combinations will give the
                         same amount of exposure.The best combination depends
                             on the results desired. Use fast shutter speeds to freeze
                              motion  or  slow ones to  qeate deliberate blur. Small
                               apertures give greater depth of  field, large ones let the
                                subject stand out againstan out-of-focus background.
                           The  table below shows how the aperture and shutter
                            speed are interrelated; all combinations givd the same
                             exposu re.

                              Aperture    rfi.q   fl2        f 12.8   tl4        f ls.6
                              Shutter
                           speed     1/s00 112s0 1112s 1l60  1130
                             (second)




                         www.orphancameras.com
View original page 17
Page 18 · Read text
fne Photomic finder allows you  to meter a light levelI
D  requiring2- to 1O-secondexposuretime at the maximum
   apertureof the lens in use. First set the shutter-speedscale
    at " 8". Turn the shutter-speedselector wh ile depressing
   the locking button in the center of the ASA film-speed
    dial until both signal lights glow. Read off the number on
   the extra-long shutter-speedscale which appearsopposite
   the white dot. Then set the shutter at the indicatedtime
   using the self-timer on the camera (see the Nikon F2 or
   F2 Photomic instruction manual). When measurementis
  made in this way, the shutter speed visible in the view-
   finder rests at "B"  regardlessof the number on the extra-
   long shutter scaleappearingoppositethe white dot.
  Rememberthat at lighting levelslower than EV 0 (e.g.,2
   secondsat  f 11.4with ASA 100 film), the exposure meter       o 8 4 2
   takes 2 to 3 minutes to reach a steady reading.
                                                         1I0
View original page 18
Page 19 · Read text
18 EXPOSUREMEASUREMENT-continued
                            MeteringRange
                                                                    lf the two  signal lights do not  light up even after all
                                     possible lens-aperture/shutter-speedcombinations have
                               been tried, then the availablelight is too bright or too dim
                                            for the meter's range. Switch to a new film that matches
                                     the availablelight; or mount a neutral density filter onto
                                     the lens to cut down on the amount of  light; or use
                                             artificial lightingto increaseluminosity,whateverthe case
                            may be. With the 50 mm  f 11.4 lens and a film speed of
                           ASA 100, the meter's effective range extends f rom f 11.4
                                           at 8 secondsto f/8 at 1l2OO0second.





                              www.orphancameras.com
View original page 19
Page 20 · Read text
1 9

  UnusualLight Situations
  When there are severebrightnessdifferences between the
  subjectand the background,you will often obtain better
  resultsby setting up the camera so that the subject fills
  the central part  of  the viewfinder during exposure
  measurement.For example, if the picture includes an
  unusuallybright sourceof light, such as a light bulb, move
  the camera to  center the  subject for  reading, or   if
  accessible,move  in on the subject to take a close-up
  readingof the part you want to emphasize,and then
  move back until the desired composition appearsin the
  viewfinder.
  For landscapeswhich include an expanseof sky, tilt the
  cameradownward during measurementto prevent under-
  exposurecausedby the bright skylight.
  For backlightedsubjects,move up close to and include
  dark areasof the subjectin your reading.


&
View original page 20
Page 21 · Read text
20 EXPOSUREMEASUREMENT-continued




  Measuringthe bright area in the
  center of  the screen will cause
  underexposureof the main sub-
  ject.





                                                          rerD G2rF
                           Keep out stray light!
                            The finder is designedto minimize the effect of light entering
                               through the finder eyepieceunder normal conditions. How-
                                  ever, in the followirrg situations,the use of a finder eyecup is
                          recommended to insure complete exclusion of stray light:
                                    o When the camera is in sunlight and the subject is in
                             www.orphancameras.comshade.
View original page 21
Page 22 · Read text
2 1




                                                        For correct exposure, first meas-
                                                        ure the light striking the main
                                                          subject,then composeand shoot.





    o W h e n  t h e s t o P - d o w n m c t l l o d  i s u s c d . r t s m . r l lJ P c r t t l r c s .
    o W h e n a s h a l t o l  s u n l i g h t f a l l s b e t r v c c n t h e c y c a n d  t h e
       e Y ep r ec e .
W h e n  t h e  s i g n a l  l i g h t s o n   t o p  o l   t h c   l i n d e r    i s u s c d  t o d e t t :r -
m i n e c x p o s u r e , t h e e y e p i e c e s h o u l d b e c o v e t e d r v i t h  t h c h a n d
t o p r e v c n t e \ t r . l n c o u s l i g h t f r o m c n t c r i n g t h e  l i n d c r .
View original page 22
Page 23 · Read text
EXPOSUREMEASUREMENT: SPECIALCASES

   S t o p - D o w n E x p o s u r e M e a s u r e m e n t
   With the following lenses and accessories,full-aperture
   exposure measurement is not possible,either becausethe
   lens has no auto-diaphragmor becausethe diaphragmwill
   not  couple with  the meter. Therefore, the stop-down
   method must be used. This means measuringexposure
   with the lens aperture diaphragm stopped down to the
   taking aperture. First, push the coupling pin up into the
   Photomic finder with a coin or similar obiect so that the
   f/number 5.6 appearsin the maximum apertureindicator
   window. Mount the lens or lens/accessorysetup on the
   cameraand switch on the meter in the usual wav.





www.orphancameras.com
View original page 23

From the M. Butkus archive. Original publisher and archive notices are retained.
Check the model and edition against your equipment.

PDF verified 2026-10-10.