Page 3 · Read text
NOMENCI-ATURE
Maxi mu m aperture indicator
Meter coupling pin
www.orphancameras.comView original page 3Page 4 · Read text
Shutter-speedselector
Ready-light
Shutter-speedindex
Shutter speedscale
(for extra-long exposure)
Shutter-speedscale
Viewfindereyepiece
Ready-light contact
Meter window
Finder releaselever
ASA film-speedindex ring
Film-speedscaleView original page 4Page 5 · Read text
CONTENTS
Foreword
Attaching the Photomic Finder 6
S h utter-speedcoupling 7
Lens-aperture cou pling 8
Maximum aperture indicator 9
Setting the film speed . 1 0
I n s t a l l i n gt h e B a t t e r i e s. . . . 1 1
C h e c k i n gt h e b a t t e r i e s. . . . 1 2
ExposureMeasurement
(fu I l-aperturemethod) 't3
Switchingthe meter on . . 1 3
Determiningexposure 1 4
Choice of shutter-speed/lens-aperture
combinations . . . 1 6
Extreme low-l ight metering 1 7
Meteringrange. 1 8 't9 Unusual light situations. .
ExposureMeasurement:SpecialCases . 22
Stop-down exposuremeasurement . . . 2 2
Exposure correction for special
lens/focusing-screencombinations . . . . . . . 24
Repro-copying,slide-copyingand
p h o t o m i c r o g r a p h y . . . . 2 6
Care and Handling . . 28
F e a t u r e s / S p e c i f i c a t i o n s . . . 3 0
www.orphancameras.comT h e N i k o n W a r r a n t y . . . . . . 3 ' lView original page 5Page 6 · Read text
FOREWORD Designed to fit any Nikon F2 camera, the Pho- tomic Finder DP-2 incorporatesa precise center- weighted CdS exposure metering system coupled to the lens-aperture and shutter-speed controls. lnstead of the usual meter needle, light-emitting diodes in the viewfinder glow bright red in two signal lights to indicate correct exposure. The signal lights are also visible on top of the finder. Besidesproviding easy-to-seemetering information even in poor light, the finder extends meter sensitivity down to EV -2 (8 secondsat f 11.4 with a n A S A 1 0 0 f i l m ) . I n c o m b i n a t i o nw i t h t h e E E Aperture Control Attachment DS-1 accessory,the Photomic Finder DP-2 provides the Nikon F2 camera with automatic exposure meteringcontrol.View original page 6
Page 7 · Read text
ATTACHING THE PHOTOMIC FINDER
To attach the finder to the camera mounted with a lens,
first set the lensaperturediaphragmat any nu mber smaller
than f/5.6, center the meter coupling pin and loosely
place the finder in position. Pressthe finder down gently
u n t i l i t c l i c k s i n t o p l a c e a n d t h e t w o c l a m p ss e t t l e i n t o
p o s i t i o n T. h e n t u r n t h e l e n sa p e r t u r er i n g t o t h e m i n i m u m
aperture setting until the meter coupling pin and lens
c o u p l i n gp r o n g a r e l i n k e d .
Mounting the finder on the camerabody without a lens is
s i m p l e . J u s t s e t t h e f i n d e r i n p o s i t i o n a n d p r e s s i t
d o w n w a r dg e n t l y u n t i l i t c l i c k si n t o p l a c e .
To remove the finder, depressthe base of finder release
lever and turn the lever downward, then pressthe finder
releasebutton on the back of the camera.The finder will
come looseand can be lifted out.
www.orphancameras.comView original page 7Page 8 · Read text
S h u t t e r - S p e e dC o u p l i n g When the Photomic finder is attached to the camera,the shutter-speeddial on the camera is inaccessible.There- fore, an auxiliary shutter-speedscale is provided on the finder. With the finder in place, rock the shutter-speed selectoruntil it engagesthe dial on the camera and the two rotate together.View original page 8
Page 9 · Read text
T h e P h o t o m i c f i n d e r t a k e s a d v a n t a g eo f t h e a u t o m a t i c
d i a p h r a g mf e a t u r eo f N i k k o r A u t o l e n s e st o m e a s u r el i g h t
w i t h t h e l e n s w i d e o p e n . F u l l - a p e r t u r em e t e r i n gg i v e sa
b r i g h t , c l e a r f i n d e r i m a g e f o r v i e w i n g a n d f o c u s i n ga n d
m i n i m i z e st h e e f f e c t o f l i g h t e n t e r i n gt h e v i e w f i n d e rf r o m
the eyepiece.
I n o r d e r t o m e a s u r ee x p o s u r ea t f u l l a p e r t u r ew i t h l e n s e s
h a v i n g d i f f e r e n t m a x i m u m a p e r t u r e s t, h e m e t e r m u s t b e
c o u p l e d w i t h t h e m a x i m u m a p e r t u r eo f t h e l e n s i n u s e .
www.orphancameras.comView original page 9Page 10 · Read text
This is done each time the lens is attached or changedas
follows:
Position the lens in the camera's bayonet mount so that
the indicator dots on the lens and the camera body are
aligned.Grasp the lens by the white milled ring and twist
it counterclockwiseuntil it clicks into place. Turn the
aperture ring all the way to the minimum aperturesetting
(largest f/number), then all the way in the opposite
direction.This step automaticallyfits the coupling pin of
the Photomic finder into the coupling prong on the lens
and adjuststhe maximum apertureof the lens.
M a x i m u m A p e r t u r e l r r d i c a t o r
The above adiustment can. be verified by checking the
maximum aperture indicator in the window on the
Photomic finder. The scale has a range from f l'1.2 to
f 15.6.For example,if the 24 mm f 12.8 lens is mounted on
the camera,2.8 should appearin the window.
lm Apcnurc scrrc $.
4._.u45
W* 2
t4
t2View original page 10Page 11 · Read text
10 ATTACHING THE PHOTOMIC FINDER-continued
S e t t i n g t h e F i l m S p e e d
The exposure meter of the Photomic finder must be
adjusted for the speed (ASA number) of the film in use.
Lift up the milled ring around the film-speeddial and turn
it so that the film speed appearsopposite the red arrow.
The film-speeddial coversa range from ASA 12 to 6400
with two dots betweeneach pair of numericalsettingsfor
i n t e r m e d i a t ev a l u e s s, u c ha s A S A 6 4 , 8 0 , 1 2 5 , e t c .
www.orphancameras.comView original page 11Page 12 · Read text
INSTALLINGTHE BATTERIES 1 1 T w o 1 . 5 V s i l v e r - o x i d eb a t t e r i e sa r e s u p p l i e d w i t h t h e P h o t o m i c f i n d e r . T h e y m u s t b e i n s t a l l e di n t h e b a t t e r y chamber on the Nikon F2 camera baseplatebefore the m e t e rc i r c u i t w i l l o p e r a t e . To installthe batteries,twist the baseplatecap with a coin or similar object to remove it and drop the batteriesinto the chamber. Make sure that the plus (+) side faces out. Then replacethe cap. C a u t i o n : R e m o v e t h e b a t t e r i e sw h e n t h e c a m e r a i s n o t usedfor long periods. A t b e l o w - f r e e z i n tge m p e r a t u r e st,h e b a t t e r i e sm a y m a l - f u n c t i o n o r c e a s et o o p e r a t e u n t i l t h e t e m p e r a t u r er i s e s again. Be careful not to expose them to severecold for l o n g p e r i o d s .View original page 12
Page 13 · Read text
1 2 I N S T A L L I N CT H E B A T T E R I E- Sc o n t i n u e d
C h e c k i n g t h e B a t t e r i c s
Pull out the film-advancelever to uncover the red dot on
top of the camera and watch the signal lights in the
viewfinder or on top of the finder. lf either of the two
lights glows with a bright red light, the batteriesare in
good condition. lf not, they need to be replaced.
www.orphancameras.comView original page 13Page 14 · Read text
EXPOSUREMEASUREMENT(full-aperturemethod)
The exposure meter of the Photomic finder features a
center-weightedthru-the-lensmetering system coupled to
the shutter speed and aperture controls. The meter reads
the light over the entire focusing screen but favors a
central area. This allows you to make precise reading of
the selectedsubiect area.
S w i t c h i n g t h e M e t e r O n
The film-advance lever also servesas an on-off switch for
the exposure meter. To turn the meter on, pull out the
lever just enough to uncover the red dot on top of the
camera.When the meter is not in use, pressthe lever flush
againstthe camera body to avoid battery drain.
I
)View original page 14Page 15 · Read text
14 EXPOSUREMEASUREMENT-continued
DeterminingExposure
The Photomic finder has two signal lights in the view-
finder, one with the plus (+) sign for overexposure,the
other with the minus (-) sign for underexposure. To
determine the correct exposure, first switch on the meter
and either of the two signal lights glows. Then turn the
aperture ring and/or shutter-speed selector until both
signallightsglow.
The signal lights are arrow-shapedso that by the direction
the arrows point you will know at a glance which
exposure control, the aperture ring or the shutter-speed
selector, is to be rotated for correct exposure. For added
convenience, the actual shutter speed and the aperture
selectedalso appear in the viewfinder.Either the aperture
ring or the shutter-speed selector (except for speeds
slower than 1/80 second) permits reliable intermediate
settings for more precise exposure of less than one
f/number. The signal lights also appear on top of the
finder for conveniencewhen the camera is held at waist
level or mounted on a tripod. ln low light, the two signal
lights may light up at "B" setting on the shutter-speed
scale.lf so, correct exposuretime is 2 seconds.
www.orphancameras.comView original page 15Page 17 · Read text
EXPOSUREMEASUREMENT-continued
Choiceof Shutter-Speed/Lens-Aperture
Combinations
The amount of light reaching the film is determined by a
combination of lens aperture and shutter speed.Since the
two are interrelated, different combinations will give the
same amount of exposure.The best combination depends
on the results desired. Use fast shutter speeds to freeze
motion or slow ones to qeate deliberate blur. Small
apertures give greater depth of field, large ones let the
subject stand out againstan out-of-focus background.
The table below shows how the aperture and shutter
speed are interrelated; all combinations givd the same
exposu re.
Aperture rfi.q fl2 f 12.8 tl4 f ls.6
Shutter
speed 1/s00 112s0 1112s 1l60 1130
(second)
www.orphancameras.comView original page 17Page 18 · Read text
fne Photomic finder allows you to meter a light levelI
D requiring2- to 1O-secondexposuretime at the maximum
apertureof the lens in use. First set the shutter-speedscale
at " 8". Turn the shutter-speedselector wh ile depressing
the locking button in the center of the ASA film-speed
dial until both signal lights glow. Read off the number on
the extra-long shutter-speedscale which appearsopposite
the white dot. Then set the shutter at the indicatedtime
using the self-timer on the camera (see the Nikon F2 or
F2 Photomic instruction manual). When measurementis
made in this way, the shutter speed visible in the view-
finder rests at "B" regardlessof the number on the extra-
long shutter scaleappearingoppositethe white dot.
Rememberthat at lighting levelslower than EV 0 (e.g.,2
secondsat f 11.4with ASA 100 film), the exposure meter o 8 4 2
takes 2 to 3 minutes to reach a steady reading.
1I0View original page 18Page 19 · Read text
18 EXPOSUREMEASUREMENT-continued
MeteringRange
lf the two signal lights do not light up even after all
possible lens-aperture/shutter-speedcombinations have
been tried, then the availablelight is too bright or too dim
for the meter's range. Switch to a new film that matches
the availablelight; or mount a neutral density filter onto
the lens to cut down on the amount of light; or use
artificial lightingto increaseluminosity,whateverthe case
may be. With the 50 mm f 11.4 lens and a film speed of
ASA 100, the meter's effective range extends f rom f 11.4
at 8 secondsto f/8 at 1l2OO0second.
www.orphancameras.comView original page 19Page 20 · Read text
1 9 UnusualLight Situations When there are severebrightnessdifferences between the subjectand the background,you will often obtain better resultsby setting up the camera so that the subject fills the central part of the viewfinder during exposure measurement.For example, if the picture includes an unusuallybright sourceof light, such as a light bulb, move the camera to center the subject for reading, or if accessible,move in on the subject to take a close-up readingof the part you want to emphasize,and then move back until the desired composition appearsin the viewfinder. For landscapeswhich include an expanseof sky, tilt the cameradownward during measurementto prevent under- exposurecausedby the bright skylight. For backlightedsubjects,move up close to and include dark areasof the subjectin your reading. &View original page 20
Page 21 · Read text
20 EXPOSUREMEASUREMENT-continued
Measuringthe bright area in the
center of the screen will cause
underexposureof the main sub-
ject.
rerD G2rF
Keep out stray light!
The finder is designedto minimize the effect of light entering
through the finder eyepieceunder normal conditions. How-
ever, in the followirrg situations,the use of a finder eyecup is
recommended to insure complete exclusion of stray light:
o When the camera is in sunlight and the subject is in
www.orphancameras.comshade.View original page 21Page 22 · Read text
2 1
For correct exposure, first meas-
ure the light striking the main
subject,then composeand shoot.
o W h e n t h e s t o P - d o w n m c t l l o d i s u s c d . r t s m . r l lJ P c r t t l r c s .
o W h e n a s h a l t o l s u n l i g h t f a l l s b e t r v c c n t h e c y c a n d t h e
e Y ep r ec e .
W h e n t h e s i g n a l l i g h t s o n t o p o l t h c l i n d e r i s u s c d t o d e t t :r -
m i n e c x p o s u r e , t h e e y e p i e c e s h o u l d b e c o v e t e d r v i t h t h c h a n d
t o p r e v c n t e \ t r . l n c o u s l i g h t f r o m c n t c r i n g t h e l i n d c r .View original page 22Page 23 · Read text
EXPOSUREMEASUREMENT: SPECIALCASES S t o p - D o w n E x p o s u r e M e a s u r e m e n t With the following lenses and accessories,full-aperture exposure measurement is not possible,either becausethe lens has no auto-diaphragmor becausethe diaphragmwill not couple with the meter. Therefore, the stop-down method must be used. This means measuringexposure with the lens aperture diaphragm stopped down to the taking aperture. First, push the coupling pin up into the Photomic finder with a coin or similar obiect so that the f/number 5.6 appearsin the maximum apertureindicator window. Mount the lens or lens/accessorysetup on the cameraand switch on the meter in the usual wav. www.orphancameras.comView original page 23