Film cameras
Omega 120 User manual
User manual for Omega 120. 26 pages in English. Read the original PDF, download or print a copy without registration.
26 pagesEnglish4.6 MB PDF

Loading your manual…Open PDF directly
Document details
- Brand
- Omega
- Model / document
- Omega 120
- Document type
- User manual
- Language
- English
- Pages
- 26
- File size
- 4.6 MB
- Category
- Film cameras
- Document date
- Not specified in catalog
Search available document text
Find a term, then jump to its page in the original PDF. Image-only pages may not be searchable; check the PDF for exact wording and diagrams.
Page 3 · Read text
the qulomqtic (
ccrmerq
is o very simply ond eosily operoted, ropid sequence,high
precisioncomero of light weight with entirely functionol
design which produces unusuolly shorp ond excellent
pictures with consistency.
The Omega | 20 ccrmercrtokes nine 2t/4" x 23/.t" pictures (4:5
proportion) on No. l20 film. This negotive size motches fhe
jt;::i!l',;#i:il: fit'r#",?i:ili!:,:,i#{f#l*
www.orphancameras.comView original page 3Page 4 · Read text
The Ovrrce 120 Cennsne was designed for outstanding performance and to produce
consistently the excellent pictures which modern optics are capable of producing
but which they can not produce when built into less precise instruments. It has
one of the finestphotographic lenses ever produced, designed especially for SrrvrnnoN
BnorHrns, fwc. and built into a high precision camera body. The Onnnca 120 will
consistently give you optimum definition because its brilliant over-sized range oulstqnding
finder is easier and faster to focus and your negative is kept absolutely flat by performonce
means of the exclusive retractable pressure plate. No fear of blurring pictures
due to jarring the camera because it is so designed as to give you a good, steady
grip.The Ortrce 120 incorporates a shutter speed of from one secondto L/400
of a second. It produces 4 x 5 picture quality on 120 film.
The Olvrnce 120 Cavrrne is fully automatic. It has automatic double exposure
prevention and automatic parallax compensation. The Autofilm Transport
fullyautomatically cocks the shutter and adr.'ances the film for next exposure
qulomqticin split seconds. Simultaneously, a red dot appears in a small window in-
dicating the camera is set for your next picture. The versatile Autofilm
Transport also automatically locks the Onnnce L20 and closes the film
window after loading.View original page 4Page 5 · Read text
As the shutter is released, an automatic film pressure plate is
actuated to keep the film precisely flat in the focal plane during
exposure which means consistent maximum sharpness ! The
exclusivefilm plate, one of the most important innovations in the Ource L20
Celrnna, is ground perfectly flat, during manufacture, oD a
pressure plote surface grinder for micro-accuracy. It is retractable and
automatically releases the film after each exposure. Ourca's
film pressure plate is a major contribution toward the su-
perb picture quality always yours with the OuBce L20.
The large, over-sized range finder with its brilliant, magni-
brilliqnt fied image and large field finds the optimum point of
over-sized definition without a moment's hesitation even in poor lighting, oD Ovrnca characteristic indispensable for effec-
rqnge finder tive flash photography. The unusually large field is en-
larged IYz times for extremely critical focusing. The
view finder shows the image at 2/sof natural size which
is also unusually large.
The Oprcce I20 Ceurne is built for quick handling
rqpid and instant action, rapid sequence photography. It
is fully automatic, has an easy-to-focus range finder, sequence a rapid Autofilm Transport, a convenient shape and
its controls are so located as to make possible Tu:o-
Hand Operation.
poge 3 www.orphancameras.comView original page 5Page 6 · Read text
And check what flash photograph5' means to you with your
Onnpce L20 Ceunne ! Ounca's new, exclusive magazine r€- qulomqticpeater flash gun changes bulbs automatically I The Omegaflash
gun is connected to the instant automatic shutter-setting and rePeqler
film winding devices. The large fast-action release lever on the f lqsh
left snaps the picture while actuating the film pressure plate.
The synchronized shutter accepts SM bulbs, No. 5 bulbs and
electronic flash.
The science of human engineering and common sense,
based on long years of experience, determined the func-
tional shape and light weight (just slightly over ZL/z
pounds) of the Ounca L20 Caunne. There are only a few
control knobs, but eaeh is very large. The release lever,
with its exclusive "rifle-trigger" action is obvious and eqsy
completely accessible. Yes, you can easily take pic-
hqndf ingtures with your Ounce L20 while wearing the heaviest
gloves ! You will like the sound design of the hand
grip on the left side of the onnnce L20 CennnRA,molded
to fit the inside of your hand for a sure, steadv, firm
hold within relaxed reach of the shutter release. Of
course, this leaves your right hand free for easy,
rapid and accurate focusing so that you actually
have an efficient, Two-Hand Operation Camerq,.View original page 6Page 7 · Read text
Functionally designed, the Ovrnca 120 Ceurna has carnera
beauty and styling all its own, a distinct departure that you'll
discover means remarkable practicality . . . it looks practical simple
. .. I and business-like, very rnuch like a small aerial camera. The
tuncllonql ail-metal camera body is of die cast magnesium. Trim, smaller
design parts, and camera accessories are of aluminum, stainless
steel, molded nylon and of high-impact Phenolic (similar to
that used on telephone receivers) ' The entire instrument
is completely and carefully rust and corrosion-protected.
Wnet A PLEASUREro usn! Remember . . ' the Orvrrce 120
Cnivmne is extremely simple to use, which is always an
. , advantage, regardless of whether you are a photographic
slmple ro expert . . . perhaps a press or magazine photographer
operote ... . or whether you are a novice just getting interested
in photography. In either case, it will take you approxi-
mately 15 minutes to familiarize yourself with the
ffi:Il: ;.3T::i l'i.,:iT""ffi,::#.;H: tion of the"':"fOvrrce 120 "Cavlnne is so simple as to
make an instruction booklet almost superfluous.
Consequently, the few following points of infor-
mation may be digested in a matter of minutes.
Poge 5
www.orphancameras.comView original page 7Page 8 · Read text
nfenls
ide to the Omegq 6. How to Trip the Shutter
0 Comerq
7. .AdvoncingFilm
ing
8. RemovingFilm
tting ShufterSpeeds from Comerq
d DiophrqgmOpening 9. Flosh
ow to Hold the Omegq I O. Flqshguideotfochmentond 0 Comero corrying coses
USrh$: I l. Filtersond Sunshode
nge ond Viewfinder
th of FocusScqle I 2. Close-upAtfochmentView original page 8Page 12 · Read text
how to set shutter speeds
qnd diqphrqgm openings o o .
After the omega 120 has been loaded with film, it It is obvious that the speed of a moving object
is ready to take pictures. For a correctly exposed has a definite bearing upon the choiee of the s*ea
picture a definite amount of light must be admitted of the shutter and that a fast moving object tatts
to the film during an erq)osure. rhis amount of for a high shutter speed.
light can be controlled in two ways; by adjusting
the speed of the shutter and by controuing the iris For an object which mov_esslowly or is stationorv,
diaphragm of the lens. we have, of course, a wider choice of speeds. Heie
rhe speed of the shutter is controlled by hrrning we must sometimes make use of t'Depth of Focus.r' 4. lris Diophrogm its rim. Ttris is facilitated by two snall projectioru; This term describes the ability of a lens to produce
Lever which are shown in Figure Z, page 9 and Figrrre r_h""p images, not merely of objects at a tefinite
2/r, Page LOas No. 6. The diaphragrn stop is ad- distance from the camera but also of objects at a
justed by lever (a) also visible on Figrrres 2 and 2A. somewhat smaller or greater distance. rheoreti-
It will be clear that severd conceivable combina.
tions of shutter speeds and diaphragm stops may
admit the correct arnount of light. The chbice ot
the best combination depends upon the following
four factors:
a. Prevailing light conditions jects lying between a eertain minimum r
b. In case of a moving objbct, the speed of the and certiin maximum distan"". iJil depth
object to be photographed width of this zone can be controlled bv ^t
c. The required depth of focus adjusting the iris diaphragrn. The furthe-r :'
we stop down, the wider this fOCuS zone will The d. ability of the individual operator to get. which have a very ex. -Fo" -objectsFis.2 A hold ttre camera steady tended depth, the iris diaphragrnstop
rn order to judge the prevailing light conditiorui, may become so small that a very slow
the use of an e)rposure meter is recommended. rhe shutter speed must be used in oider to
most frequently used makes are weston and Gen- obtain adequate e:rposrlres. In such cases,
eral Electric and by following the instructions of the camera should be placed on a tripod.
these marrufacturers, proper exposures can be ob. The use of the "Depttr of Focus" scale is
tained without di#ficulty. explained on page tt l4
poge l0View original page 12Page 13 · Read text
how to hold rhe omesq 120
duringexposures...
The left hand of the operator should hold the during the exposure. The Omega L20 Camera
camera firmly by the convenient handle (10) can obtain far sharper pictures than ordinary
attached to the left side. The trigger finger of cameras. This ability is not only due to the
the left hand should be placed in front of the special photographic advances built into the
release lever (9). The thumb of the left hand camera, but also the functional design which
should be placed in the thumb rest at the left makes the Omega L20 so easy to hold with
upper corner of the camera back. The thumb steadiness. Do not underestimate the impor-
and trigger fingers of the right hand should tance of holding the camera steady during ex-
actuate the focusing control (11) while the posures. Because pictures with the Omega L20
Autofilm Transport (16) should rest on the are capable of being precision sharp, small
lower part of the right hand thumb. The cam' vibrations can adversely affect the detailed
era should then be pressed firmly against the image.
face of the operator in such a position that one For vertical exposures, the Omega L20 can
of his eyes can observe either the range finder be held in a very similar manner except that {or the view finder. These conditions are shown the left hand holding the hand grip is placed
in Figures 6, 7, and 8. above the right hand actuating the focusing
The camera should not be held in mid air knob. Again the camera is pressed firmly
because this is very likely to cause vibrations against the operator's face as shown in Fig. 7.
poge I I
www.orphancameras.comView original page 13Page 14 · Read text
focusin gr howro use
the view ond ronge finders o . o
The view ffnder and range finder of the Omega 120 are purposely formed by separate
optical systems. This is desirable for best performance and sensitivity. The view finder
must present to the observer the entire field to be photographed, necessarily at a reiluceil
scale. However, the range finder must, for best sensitivity, show the center of the image
at an enlarged scale. Since one system calls for magnification and the other for reduction,
they obviously cannot be combined without impairing the performance of the range finder.
lhe view finder is an inverted telescope (inverted because it is reducing instead
of magnifuing) which shows the scene to be photographed at approximately two- view thirds of its actual size. It is fastened to the top of the omega 120 by a hinge which
finder forms part of an automatic parallax compensation, (The term ,,parallax" de-
scribes the small but not negligible difterence between the view finder image .:
and the image formed by the camera lens upon the film when the camera is 'j
focused at distances smaller than infinity. This difrerence is caused by the fact i
that the view finder is displaced or ofiset relative to the optical axis of the camera
lens.) The automatic parallax compensation tilts view finder slightly when the
focusing mechanism of the camera is adjusted to distances smaller than infinity.
IView original page 14Page 15 · Read text
fOGUSing (conrinued)
The range finder consists essentially of a tele- then be observed through the range finder lrn'
scope with approximately Lr/z times magnifica' til the actual exposure is taken. As an alter-
tion and a reflecting system which includes a nate method, it is sometimes possible to pre'
ronge beam splitter formed by a half transparent focus the Omega L20 at some suitable dis'
mirror. Two images are seen superimposed tance and then let the object "walk" into the finder
upon each otheri i.€., objects are seen with field. In either case, observing the obiect
double contours. When the focusing movement through the range finder will enable the oper-
of the Omega 120 is actuated by turning the ator to snap the picture when the two images
focus control (11), one of the images shifts Btl- in the range finder coincide. When photo-
tomatically. When both images are in coinci' graphing moving obiects, some allowance
dencei i.€., when an object is seen with single must be made for the time lapse between the
rather than double contours, the eamera is precise moment the operator decides to snap
accurately focused upon this object. the picture and the instant he actually snaps it.
For stationary objects, it is best to focus T'he shutter release of the Omega L20 Cam-
through the range finder first and then to frame era has purposely been designed with a rela'
the picture carefully in the view finder to get tively long stroke. Since less pressure is
the best compositions. required with a long stroke than with the usual
When photographing moving objects, the short stroke, a much "softer" release has been
scene should be framed approximately through achieved. The danger of vibrations during the
the view finder first. The moving obiect should exposure has thereby been firrther minimized.
Fig. ll fronf view
poge 13
www.orphancameras.comView original page 15Page 18 · Read text
After the exposure, pull the Autofilm
Transport (16) out to the stop and
push it back. This will not only
advance the film but will also auto-
odvqncing maticallyexposure. resetft is necessarythe shuttertoformovethe thenext
the film oo. stroke can be reversed. Thistransportmovementall shouldthe waybeoutdonebeforewiththecare
and not too fast and particularly without jerking. Please keep in
mind that this method of resetting the camera is exceedingly fast and even if done slowly, it is still much faster than any other method. /I
Do nol remoye Comero Bock when Aurofilm Tronsport is extended.
Do not operole Aurofilm Tronsport when Comerq Bqck is removed from cqmero.
After e)q)osure No. t has been taken, pull the
Autofilm Transport (16) four times (and not too
fast) until the word "open" appears in the
window (20) of the exposure counter; turn the
Starting knob (17) 2 or 3 times; then turn Locking removing the knob (2L) counterclockwise thereby unlocking
film from thethe eameraleft sideback.first byDetachmeanstheofcameralocking backknoblifting(zL). rnvert
the camera (so that the lens points upward).
thg Gqmerq o.. Rest camera on either open hand, your hand
being beneath the pocket which contains
the finished film spool. Pull the plunger (1b)
and let the film spool with the film
drop into your hand.
poge l6View original page 18Page 19 · Read text
Shutter speeds of U400 and 1/200 sec. (marked X) are synchro.
nized for electronic flash (with zero time delay).'-ff'WE shutter Shut_ter speeds of 1/100 and 1/50 sec. (marked F) are synchro.
synchroni- nized for Type SM or SF Flash Bulbs (with time delay of ap- proximately 5 milliseconds).
zqtion Shutter speeds of. L/25 and 1/10 sec. (marked M) are synchro.
nized for No. 5 Flash Bulbs (with a time delay of approximately
20 milliseconds).
There is a large number of flash attachments (battery cases)
flqsh available which will work properly with this camera. A flash attachment consists of a reflector, a lamp socket and a container
qttqchment with a battery. It has an electrical connector which must be
connected to the contact (7) of the shutter. Do not use any of
the older types of synchronizers which contain a mechanical
or electrical mechanism to release the shutter itself. The shutter
should be released as described in section 6 by means of the
release lever (9).
A particularly rapid way to use an Ovrrcn 120 Cevrnne with
flash is provided by the Omegaflash Unit which makes a very
rapid succession of flash pictures possible because it automati-
Omegoflqsh cally changes its own lamps after each picture. The Omegaflash consists of a housing which can be attached
unit to the lower surface of the camera. It contains not only the
for ropid batteries and a capacitor but also a gear mechanism which is engaged to the fiIm winding knob (17). On one side of the hous.
sequence ing is a reflector and a rotating lamp turuet which accepts six
lamps and which is rotated automatically after each picture
while the operator changes the film by pulling the Autofilm
Transport (16) in the customary fashion.
To provide a base upon which the Omegaflash Attachment
can stand, snap out folding support (29). To return support (29)
to rest position, depress spring lever immediately adjacent to
www.orphancameras.comthe support.
*"fu*ci-,,,View original page 19Page 20 · Read text
OMEGA I20 CAMERA Page 17 of the instruction booklet on the OMEGA 120 CAMERA refers to the shutter synchronization. It was I
wirh full y synchronized shulter written for a so-calledXFM shutter which can be used with strobe lights, with Type SM or SF Lamps, and
with No. 5 and similar lamps at SELECTED shutter
speeds.
we are ngw supplyirg, as optional equipment, a so-
called fully synchroniZed shutter whi-ch ean be used
with strobe lights, Type SM or SF Lamps, and No. b
and similar lamps at substantially ALL shutter
speeds.
This shutter has an additional diat on the left side.
This dial has three positions: one marked Fx (F in
red and x in black), one marked M in red, and one
marked M in black. These markings denote the fol-
lowing:
In the first position (FX) the shutter is synchronized
for strobe lights at all shutter speeds. In the same
position the shutter is also synchronized for Type SM
or SF Flash Bulbs (with a time delay of approximately
5 milliseconds) at shutter speedsof L/50-of a second
or slower which are marked in red on the shutier
speed dial.
The two positions marked M are to be used for No. 5
be used for shutter speeds marked in black on the
shutter speed dial, i.e., I/100 of a second or faster.View original page 20Page 21 · Read text
The flash gun is fastened to the camera by means of a screw which
engages the thread otherwise used for the tripod. This screw can be
how to rotated by small knob (26). See Fig. 18. When the flash gun
qttach fhe is attached" to the camera, attention must be paid to a small pin (25)
Omegqf lqsh which engages a corresponding hole located near the film
winding knob. This pin keeps the flash gun from rotating. The gear ,, qttqch ment mechanism is engaged to knob (17) bV means of two prongs which
enter corresponding holes within knob (17). A knurled knob (26A)
permits the rotating of knob (17) after the flash gun has been
attached to the camera. It is, therefore, possible to load the camera in
the customary way without detaching the flash gun. Instead of
turning knob (17) for the initial film winding, knob (26A) is used.
The lamp turret is visible in Fig. 20 and can be attached to the
threaded end of the rotating shaft (27) by means of knurled knob
l o m p (28). (Turn in a clockwise direction.) The lamp turret contains
turret lamp sockets of conventional design which can be loaded
with flash lamps in the usual manner'; i.e., the two pins on either'
side of the lamp socket enter corresponding slots, the lamp
is depressed and slightly rotated in a clockrvise direction.
Occasionally when the lamp turret is attached to the flash guD,
the lamp within the reflector will not be exactly in its center'.In
this case, the entire turret can be rotated in a clockwise
direction until one of the lamps is in the proper position. (No
great accul'acy is required.) It will be found that the tun'et is
held with some slight friction which can be easily overcome.
N O T E : A l w a y s o t t o c h t r o n s p o r e n t S o f e t y S h i e l d ( 3 3 , t
t o f l o r h g u n b e f o r e u s i n g
poge I I
www.orphancameras.comView original page 21Page 22 · Read text
Whenever the operator resets the camera by means of pulling
handle (16), the lamp turret will make U6th of a revolution
placing a fresh lamp into the center of the reflector. (Notr: The
relatively large cutout of the reflector causes only a very slight
loss of light. Approximately 60% of the lieht falling upon an
object comes from the lamp itself and approximately 407o
lomp lurret from the reflector. The cutout causes less than r/E of. the 40/s to
(continued) be lost; i.e., no more than L0% of the total light, which is
negligible.)
The ease with which the lamp turret is attached to or detached
from the flash gun by the knurled knob (28) means even greater
rapidity, convenience and continuity in using flash. An extra
turret may be pre-loaded with flash lamps. The loaded turret
replaces the used turret enabling the operator to take another
set of rapid sequence flash exposures.
The flash gun is equipped with a folding support (29) which
permits the flash gun and the camera together to be placed con-
veniently upon a flat surface when not in use.
Since this flash gun is equipped with a capacitor, batteries do
not require renewal for long periods of time. When the occasion
exlrq does arise, however, remove the lower cover from the flash Bur,
as shown in Fig. 23, whereupon the batteries become easily
turref accessible. Three batteries are used, size A-A, manufactured by
most battery manufacturers (glL6" dia., L7/e" long, Lr/z volts).
Be sure that the batteries are inserted in the proper direction.
A corresponding inscription showing this direction is found on
the inside of the flash gun housing.
p o g e l 9View original page 22Page 23 · Read text
reodingflcsh guide ottachmentl0direct
ond l o CClff ylng CelSGS.. o
Direct Reading Flash Guide Attachments are valuable and pr.actical
fiash accessoliesthat completely eliminate the necessit5'1ol ionsulting a
conl'elsion table in oldel to find the collect lens-opening for zr given distancc.
TheS' slip ovel the large focusing knob and cover.the distance siale :rnd in
its ste:rd shou' a scale of lens-openingsso that the led indicator' :rutomuticzrlll'
points out the con'ect one r.ight after.focusing. Dir.cct Readir-rgFlash Guidc
Attachrrcnts :rle zrvailable fol valious film speeds as follou's:
#A- l/50-l/100 sec. ASA 50-80 (Supel XX) SM Bulb.
#B - Blank to fill out to suit individu:rl r.equilement.
#C 1/50-1/100 sec. ASA 25-,10(Plus X. Velichr.ome) SM Bulb.
cq r rYing cqses
LEATHERCAn ERA CASE (C103). X{ade of finest saddle-
stitched tatr sircldle leather f or Orrrca 120 C.r.lrERA.Fil
ters. Srttrshitcle.other accessories. incltrcling acljr,rstaltle
shotrlder .stlult.
TEATHERCARRY-AII CASE (CI33). I\{ade of finest saddle-
stitched tan saddle leather u,ith sl)ecial fittings for
Onrrca 120 C.rnrERA.Ontegaflash Attachrtrent, Sltare Tur-
ret. and all accessoriesincluding sl)are br-rlbsand film.
A L U M I N U M C A R R Y - A L IC A S E( C l 3 5 ) . S a t i n F i n i s h e d a l u -
nrinull) cASe b]' Hallibtrrtorr. u'ith sl)eciill fittings for
orrnc.r 120 c,.r:rrERA.orlregaflash altachnrellt. sl)are Trrr
ret. ancl illl accessories including sl)are br-rlbsand filnr
www.orphancameras.com Pqge 20View original page 23Page 24 · Read text
For. black ancl u'hite Pernchlomatic Film, generally only a \:cl'y
light yellou, (K-l) or green filter is needecl trnd cvelr that cetll
f ilters oftel be dispensed u'ith. We caution against the use of ttunec-
cssar.il5' heavy filters because they u'ill usuttlly not itrrpt'ove
pictor.ierl quality nncl mclely prolong the cxposure time. It doesil not follon, that if a u-eak yellorv lilter is good, a stlong yellou'filrers filtcl rvill bc bettcr'.
For colol pictr,u'cs il so-cnllecl "Sk5'light" filtcl mttst bc uscci.
(This is a colorlcss Iiltc''r' that ubsolbs cxccss ultraviolet lightcrnd
u'ithout cattsing extctlsiou of the expostrre tirne.)
Thc Llse of a sunsharde is stlongly lccommcuded, particulallS'Sun5hqde. o o {or.pictur.cs ngninst thc light. It prevents oblicluc light ra}'s ft'otn
str.ikilg thc lcps snr'fncc ancl causiug unl]ecessaly glarc u'itl-rin
thc lcps 11'hic[. in tuln. ploclucc.s iln ovclall fog ovcl thc ctrti|e
pictLp.c. Sin-rrnon Blothcls hervc clcsignccl a specizrl suushtlclc for'
thc Omcga 120 Camera. A filtcr' (32) nra)' be set directly into
tis.21 speciol 1hc distinctivc sunshade ancl is hcld filmlS,'in position b)'
kn11r.lecl klob (30). This al'r'angemcnt allou's the opet'zlto| to
Omegq trtilizc both sunshade and prefelrecl filter sirnultaneottsl}'for
sunshode cxposLrr.es. To change filtels s'itl-rotrt clctaching the sunshaclc
f r.om the culn-rcln. sin-rpl1' loosen thc lit-tt-tllccl knob (30). Wllcrl
lsir-rg the sunshaclc u'ithor-rt ar filtct', thc sttnshade adapter' (31)
sits ilto the filter.r'irn and casily Iits the unit outo thc cttt-t-lel'tl.
p o g e 2 lView original page 24Page 25 · Read text
F12 close-uperttachmenl... r-*t".s\-
,.Frfa.
The close-Up Attachment consists of t'r'o parts; a supplementar.y lens to be
placed in f'ont of the came.a lens itseif and an adapto. *'hich changes the
rzrngefindcl and vieu'finder chalactelistics in a suitable lranncr.. This acl:rptor
is placed in f'ont of thc srnallel s'i'dou' of the r.ange finder. b1- mc.zr.s of a
clip (23). Pa.t of this adapto' is a smnll p.isrn or.*'edge *,hich cleflccts
the beam of the vic*' lindc' in acco'dance *.ith the croser ciista.ce,
of the object. A.rother. ur.rit in the ad:rptor. is a cieflection dc'ice
s'hich changcs the base distancc and thc dilcction of one beam
of thc range findcr..
When the calnel'a is equilrped u'ith these accessor.iesit can be
focused upon objects at distances of f.om 18" to 36". The objcct is obscr.r.cd 'b,,
th|ough thc vicu' findcr ot' r'angc findcr lespcctively in the cr,rstor)tll.\' l-nal-lncl'apcl focusing o2,.?v/p , . $ d
is clone in thc usr-ralrvay b1'turr-ring a focusing contlol (11). Thc footagc scllc o1 focusing
coutt'ol (11) as n-ell as dcpth of focus scale (12) mr-rst.of cour.se,be clisr.cgar.clccl|cc11rse
thcil lcaclings :ll'c no\\' mcaningless.
Attcntion is called to thc I'act that at this closc distancc, thc clepth of focus is cluitc srnall
and that it is. thercfole. \'cr']'clcsilablc to use as srnall zrstop of tl-rcirlis cliaphr.ag'r as possible. This,
in tlt|u. lllczrns thzrt ol'tcn a|tificial light il'ill havc to bc suppliccl in or.clc| to rnulic this possiltlc,
cithcl b5' mcans of flash or. b5' r-neansof er snfficicntlv highpou.cr.ecl lzrmlt. unlc.ss thc
oltjcct cau be- terken in r.c:rsonabl5' br.ight sr-rnlight.
www.orphancameras.com Page 22View original page 25Page 26 · Read text
SITUTMONBROTHERS,I NC. AREATWAYSATYOURSERVICE Any OMEGA 120 CAMERA owner with recommendolions,questions,problems or in need of service should contoct our Technicol Expert, Mr. Wolter Archinol. Telephone STillwell 6-2220 or write Mr. Archinol in core ofView original page 26
From the M. Butkus archive. Original publisher and archive notices are retained.
Check the model and edition against your equipment.
PDF verified 2026-10-10.