Page 1 · Read text
www.butkus.us
IIIIITIIITTNTNNIrrtf,nrnt lnstnuctionrrnnnntrI Elook fortxtIltII PlusrnetersTNTITIII ,|,|c!sir,leclIDIINIII CtrISiAtStltIIt 13CI CtrISi lncident
#,t'/*,,,*View original page 1Page 4 · Read text
www.butkus.us OPERATING INSTRUCTIONS FOR I2O Cds AND I3O CdS '1.Instoll Bottery - Removd Bottery Cover (1) wirh coin qr screwdriver ond insert bottery with positive "+" side up ond reploce cover. lt is odvisoble to remove bottery for long storoge pcriod. 2. Bottery Check - To check the bottery condition, depress the Bottery Test Button (3) ond nole pointer. Pointer should be on, or to the right of Bottery tesl Mork on the scole. lf the pointer is lo the left of the Mork, reploce the bottery immediotely. NOTE: Ploce the Hi-Lo Selector Swiich (Z) in the "OFF" position when meler is not in use. 3.Check Pointer Alignment - With Hi-Lo Selector Switch (2) in "OFFI position, Pointer (3) should be on zero. lf Pointer is of f zero, inseit screwdriver into Tero Corrector (lS ond turn il clockwise, or counter-clockwise until Pointer is on zero. 4. Set Film Speed - Set Film Speed Index (5) by roototing Diol (6) with Diol knob (z) until the index number ASA/DIN supplied with the film is visible in Window (B) ond oligned with the index mork. 5. Select Scole - The Hi-Lo Selector Switch (2) hos four positions: OFF, Bottery test, NORMAL LIGHT ond LOW LEVEL LIGHT.View original page 4
Page 5 · Read text
FOR r20 CdS ONIY 6. Point lhe meter loword the subiect to be photogrophed. The pointer (3) will indicote o number on the light indicoting scole (f S). Turn outer diol (S) uniil index mork (f O) oppeors ot the some number on scole (lA) os the poinler reoding. Select o shutter speed ond f/stop combi- notion f rom shutter speed scole (t t) ond f/stop scole (12,1, respectively. FOR I3O CdS INCIDENT ONIY 7. Reflected Light Meosurements - To meosure reflected light, set Boffle Slide (16) to open the photocell ond point the meter ot subiect. Set Hi-Lo Selector Switch (2) to Normol light position. Note number on the scole under Pointer (3), ond rotote outer Diol (g) until Index Mork (t O) oppeors ot the some number os the pointer reoding. Select o shuiler speed ond f/Stop combinotion from the Shutter Speed Scole (tt) ond f/Stop Scole (12) , respectively.View original page 5
Page 7 · Read text
OPERATING INSTRUCTIONS FOR MODEI IIOS
l.Set the ASA/D|N number supplied with your film in the film speed window (1) by rototing
the f ilm speed diol (2) usins diol knob (3) .
2. Point lhe meter loword the subiect to be photogrophed. The pointer (a) will indicote o number
i
on the scole (S) . Turn outer diol (6) until index mork (Z) oppeors ot the some number on j
scole (g) os the pointer reoding. Select o shuller speed ond f/stop combinqtion from shutter I
speed scole (p) ond f/stop scole (lO) , respectively. i
,
FOR llO3,l2O CdS and t3O CdS INCIDENI
3. Pointer Alignment - To check for correcl pointer olignmenf, qompletely cover photocell (l l)
foprevent ony light from entering the meter. lf pointer is off zero, inserl screwdriver into
zero corrector (tZ) ond turn clockwise, or counter-clockwise until pointer is on zero.View original page 7Page 8 · Read text
www.butkus.us
8. Incident lieht Meosuremenls - Incideni Light reodings ore exlremely useful for porlroits,copy
work ond londscopes. To meosure incident lighi, set Boff le Slide (tO) to ploce the Diffusor
(tS) in front of the photocell. From the subiect to be photogrophed, point lhe meter
directly ot the comero ond note the reoding on Light Indicoting Scole (14) under the Pointer
(3). Rotote the Outer Diol (9) until Index Mork (tO) oppeors ot the some number os the
f^t pointer reoding. Select o shutter speed ond f/Stop combinotion from the Shutter Speed Scole
(t t) ond f/Stop Scole (tz) .
9. For low level lighting conditions os usuolly encountered indoors, set Hi-Lo Selector Switch (2)
to the low level light position.View original page 8From the M. Butkus archive. Original publisher and archive notices are retained.