www.butkus.us
how to use your
exposure
rtreler
N O, 9712
SEARS. ROEBUCK AND CO. AND SIMPSONS.SEARS LIMITEDView original page 1Page 3 · Read text
www.butkus.us
homs ttm o*pEaim cc
l. Locate ASA fltm rating
Refer to ASA INDEX table (Fig.
2) and find your film's ASA
speed rating. lf not listed, con-
sult film directions. Write in its
name and ASA rating in blank
space on table.
Use ASA "Daylight" number for
outdoor exposures, and ASA
"Tungsten" number for indoor
exposures.
2. Aim meter at rubject
Hold meter in position so that
photo-cellwindow (A) is pointed
toward object or scene to be
photographed.
figure 2View original page 3Page 5 · Read text
I
Drrect exposLrres
Aim below the horizon for out- Read shutter speed (TIME) and
door pictures. its matching lens opening (f/-
stop) on lower portion of both
Exposure Meter dials. All lensi3. Rced llght vtluc rcalc
openings (f /stops) which appearI Note the LIGHT VALUE number opposite given shutter speeds indicated by red poinler on (TIMES) are exact sqttings for
I LIGHT VALUE scale (See Fig. 1.)
correct exposures.
l. Determine rhqtter speed Set your camera lens opening
and lens openlng (f/rtop) (f /stop) and shutlerspeed (TIME)
tneFER TO FtG. 3) to same markings as indicatedI
iTurn LIGHT VALUE dial on Ex- above. Always choose the com.
posure Meter until selected sub- bination of lens opening (f /stop)
ject's LIGHT VALUE number and shutter speed (TIME) which
lines up with your film's ASA comes the closest to matching
INDEX number on lhe inner dial. you r camera's settings.
EI .-"r. >View original page 5Page 6 · Read text
www.butkus.us filrn name: "daylight" ASA rating suppose light ualue nurnber is . turn light value dial on exposure meter until lig.ht value number 7 is opposite your film's asa index number 64 on inner dial . suppose we select a shutter speed of 1 /100 second, you will note that lens opening indicated is f:8View original page 6
Page 7 · Read text
. set your camera's shutter speed and len( opening .to the
same settings as indicated in fig. 3
. shutter speed set'ting (time) must be set exaclly on de-
sired speed
. lens opening (f /stop) can also be set between the numbers
If the subject is rnouing, always use a fast shutter speed (TIME). Sel,ect 1/1OO second
TOTE rather than 1/50 or 1/25 second. If thc subject
is not moving, sel,ect a slauer shutter speed with
a smalLer lens opening. (For exampl,e, 1/50
second at f:11).View original page 7Page 8 · Read text
www.butkus.us
your
',,
ffi''ffi'bt
excposure meter...
quickly shows correct shutter
speed and f/stop for still or motion pictures
highly accurate for indoor, out-
door light readings
shows proper exposure settings
for black and white or color film
it is a precision instrument.
handle it as you would a fine
watchView original page 8Page 9 · Read text
your Tower etcposul indoor pictrrres Locate your film's ASA "Tungsten" (in- door) rating in ASA INDEX table. This ASA rating helps you determine correct ex- posures for indoor picture-taking, Use exposure meter as previously described. for llash piclures Refer to instructions enclosed with your photo flash bulbs. The TOWER exposure meter is used for taking pictures under all kinds of lighting conditions except flash,View original page 9
Page 10 · Read text
www.butkus.us
re meter has additionnl trses . ..
rrrorries
Determine the ASA INDEX number, indoor
or outdoor type. Then match LIGHT VALUE
and ASA INDEX dials as previously ex-
plained. When your movie camera is oper-
ated at normal speed (16f rames per second),
select the lens opening (f/stop) nearest
1/30 second (TIME) at bottom of outer dial
on exposure meter.
f illers
For exposures using filters, refer to instruc-
tions enclosed with yourfilters to determine
adjustment for correct exposure.View original page 10Page 11 · Read text
color tilrn Avoid too much contrast (deep shadows and bright spots) in the same color picture. 1'-ero"lo lhe trteler Occasionally, the exposure meter gets out of adjustment, This is due to altitude, tem- perature or a slight jar. Red pointer on LIGHT VALUE scale should be at "zero" when meter is held in horizontal position, and no light is falling on photo-cell window (A). To reset, cover the window with your hand. Then turn screw (E), either right or left, until red pointer is exactly on zero.View original page 11
From the M. Butkus archive. Original publisher and archive notices are retained.