Home/Butkus archive/Spectra
Film cameras

SPECTRA COMBI II User manual

User manual for SPECTRA COMBI II. 63 pages in English. Read the original PDF, download or print a copy without registration.

63 pagesEnglish4.2 MB PDF
SPECTRA COMBI II manual cover
Read the manual Original PDF
Download PDF
Loading your manual…Open PDF directly

Document details

Brand
Spectra
Model / document
SPECTRA COMBI II
Document type
User manual
Language
English
Pages
63
File size
4.2 MB
Category
Film cameras
Document date
Not specified in catalog

Search available document text

Find a term, then jump to its page in the original PDF. Image-only pages may not be searchable; check the PDF for exact wording and diagrams.

Page 3 · Read text
www.orphancameras.com

FOREWORD
Congratulations!You now own the Spectra*Combi ll*  -  the world's mostodvanced,mostsensitive,
direct-readingexposuremeter.The Combi ll featurestwosilicon-bluecellsfor incident-light,reflected-
f ight and the unique Spectra"incident-reflectedaverage"measurement.The meter isdirect-reodingin
f/stops,and coversa sensitivityrangeof 25 million to one.
This manualhas beenpreparedto enableyou to enjoy optimum performancefrom your new meter.
The informationset forth in this manualwill serveyou overthe years,and the few minutesyou invest
now to acquaintyourselfwith its contentswill reap rewardsfor you throughoutthe life of your
instrument.

CAUTIONNOTES
   1) Your Spectra@exposuremeter is a precisioninstrumentand shouldbe handledas such.Do not
drop the meter or subjectit to excessiveshock,vibrationor temperatureextremes!Store it in its
carryingcaseor shippingcartonwhen not in use.
  2) The instrumentis shippedwith the battery removedto preventpossibledamagecausedby a
leakingbattery.(lnstructionsfor installingthe batteryare givenin Section5.2 of this Manual.)When
installing the battery, check that  it is installed as indicated on the polarity lobel inside the battery
comportmenLlf the instrumentis to be storedfor a long time, removethe battery.
  3) Do not attempt to check or adjust the meter zero before readingSection5.4 "Meter Zero
Adjustment".


 *"Spectro"  ond "Combi   ll"  ore trodemorks of the Photo Reseorch Division of Kollmorgen Corporation. (See Section
 6.5 for o complete  list of trademarks.)
                                        I
View original page 3
Page 12 · Read text
www.orphancameras.com

1.0   OPERATINGINSTRUCTIONS:EXPOSUREDETERMINATION
This Sectionoutlinesthe correctoperatingprocedurefor useof the SpectraCombi ll exposuremeter
for determiningexposure.The readeris referredto the illustrationson the inside-frontcoverfor parts
identification.

,..1     CONDENSEDOPERATINGINSTRUC.  TIME window (or in the CINE window, for
TIONS                                   motionpicturecameras)
The following is a brief outline of operating     3)  Preselectthe light-levelrange (Hl, MED
instructions.For additional information,see   or LO)
Section1.2 through1.6.                      Usingonly the raisedRangeSelectorActuator,
                                               turn the computeruntil the appropriateword -
                                                 Hl, MED or LO    lines up with the Range
1.1.1   Settingthe Computer                    lndicatorArrow (at the bottomof the computer).
  1) Set the Film Speed                                   NOTE: Usethe Hl rangefor outdoorsand highLift the Film SpeedSettingTab (seephoto "A"                                                              light levels,MED for indoors,and LOat feft). Turn the outer dial of the computer(see                                                               for low-light-levelphotography.photo "B")  until the FILM SPEEDlndicator
points to the ASA speed of the film you are                                                   1.'1.2  Makingthe Light Readingusing.Then pushthe Tab down (seephoto"C")
to lock-inthe setting.                          For incident light measurements,proceed as
                                               follows:  2) Set the shutter speed
Turn the outer dial of the computeruntil the      1) Set the FunctionSelectorSwitch(on the
shutter speed you desire appearsin the EXP   backof the meter)to the INCIDENTposition.





                              AeJ^,;-,,             /    .        .:b
View original page 12
Page 13 · Read text
www.orphancameras.com

   2) From the subject position, point the Photo-     REFLECTED-LIGHTM EASUREMENT   @sphere  towords the comero.
          I NCIDENT-LIGHTMEASUREMENT

            EQUALTLLUMTNATT0N



                        \
                aI

  CAMERA
    NORMAL L I G H T
                                                      3) Proceedas indicatedin Section1.1.3.
   3) Pressthe on loff burton, as indicaredin         'l                                                                                            .'l .3   Readingthe ExposureSection1.1.3, to take the reading.
                                                      1) Squeeze the On l}ff  burton and hold  itFor  reflected-light measurements, proceed as                                                         until the meter pointer comes to  rest; thenfollows:
                                             releasethe button slowly.
   1) set the Function selector switch (on the                                     NOTE:   lf the meter pointercomesto rest in theback of the meter)ro rhe REF.LECTEDposition.                                                      red portions of the meter scale, it  is
  2)  Point the Reflected Light Sensor towords            advisable to chonge the Ronge Selector
the importont part  of the subject, being certain           and repeot the light reoding, lf the meter
to include both h ighlight and shadowareas.                 pointer is in the red portion at the right
View original page 13
Page 14 · Read text
www.orphancameras.com

                                                                 '|..2        side of  the scale, move the Range       SETTINGTHE COMPUTER
        Selectorone rangecounterclockwise,lf                                                   ",.2.1  Settingthe Film Speed         the pointer is at the left side of the
         scale,moveone rangeclockwise.         Settingthe Film Speedneedonly be donewhen
                                             the meterissetinitially,or whenyou arechanging   2) Read the f lstop indicatedby the position                                                   film types.Onceset,the film speedis lockedin of the meter pointer. (View the meter from
                                                     until reset.The settingprocedureis asfollows: directly over the meter pointer.)
   3)  lf you would prefer to use a different     1)  Lift the Film SpeedSettingTab (themetal
                                             tab in the centerof the computer),as shownin f f stop,simplyturn the outerdialof the computer
                                         photo"A" oppositepage1. until the preferredf lstoplinesup with the meter
 pointer. (Note that this operationalso changes    2) Turn  the outer dial  of  the computer
 the shutterspeed!)                            (thef/stopdial)untitthe FILM SpEEDlndicator
 1.1.4   Battery-TestProcedure               on the computerpointsto the ASA speedof the
                                                   film you are using.(lf your film is ratedonly in
The internalbattery should be testedafter it is   DIN speeds,use the conversiontablein Section
 installed,and periodicallyin use.The procedure  6.4 to convertto ASA speeds.)
 is asfollows:
   1) Pressthe BAT TEST pushburtonon the   CAUTION: Do not force the computerpastits
back of the meter, while simultaneouslypressing           FILM SPEEDIiMitS- ASA 25,OOO
the main On/Off burton.                              and FC - as this may resultin per-
                                                manentdamageto the computer!
   2) Observethe positionof the meter pointer
on the meterscale.lf the meterpointercomesto       3) Push the Film SpeedSetringTab down
rest to the left of the "B.T.,,dot, the battery is    firmly (asshownin photo "C" oppositepage1)
weakand shouldbe replaced.                      to lock-inthe film speedsetting.



.,;                .              .;rir,i;io:i,t..,                           ;. r".-   "         -        ,,;itri*,,:,...,i.;;.                 ',-:r.:i                                                                                                                                                                              r!r*'l!J,ii;           -
View original page 14
Page 15 · Read text
www.orphancameras.com

1.2.2   Setting the  Shutter Speed (Exposure
T i m e )                                                                                                                                                               |    |  ,{-ta,
                                                         1/25-L             !t'*s.d
The shutter speed can be set either before or          1/50---.-r              TMTNUTES
after taking the light reading, but  it  is usually        1 / 1 O O +
done before. The shutter speedis set by merely        1 / 2 O O +                                                                                                                                                        'l
 t u r n i n g t h e o u t e r c o m p u t e r d i a l u n t i l t h e d e s i r e d       /4OO+
 r e a d i n gl i n e s u p w i t h  t h e s i l v e r l i n e i n t h e E X P
T I M E w i n d o w  ( o r   i n   t h e C I N E w i n d o w ,  f o r
motion picture cameras).

Note the markingson the shutter speeddial (see                                                                                                         I N E
 illustrationat right). The numbersthat appearin                                                                                             ( F r a m e s / S e c o n d    )
 t h e E X P T I M E w i n d o w a r e b l a c k a n d s i l v e r .
 Fractional-secondExposure times (from  112
through 1/8000 of a second) are printed with   The markingsfor cine camerasare silveron a red
silver letters on a black baclcground.Exposure   background,the numbersare "frames per second"
                       .l
 times from             second through 30 seconds are    for the most common shutter type  -  the  | 73"
 black, and also have a  letter "s"  for  clarity.   shutter - which providesa 1 150secondexposure
Times from 1 minute through 30 minuteshavea    at 24 frames per second. lf your movie camera
 letter "m"  , while 1 through 8 hour exposuresare    shutter is significantlydifferent than this, do not
 indicatedby the letter "h". The illustrationalso   u s e t h e C I N E w i n d o w o n  t h e c o m p u t e r ;i n s t e a d
 indicateswhere to set the computerfor unmarked   convert the frames per secondfor your particular
 s h u t t e r s p e e d s-  s u c h a s 1 1 5 0 o r 1 / 1 0 0 o f a   camera into an equivalentexposuretime, and use
second.                                                                                    t h e E X P T I M E w i n d o w .
View original page 15
Page 16 · Read text
,{fi,i                                  www.orphancameras.com

         "1.2.3  Settingthe Light-LevelRange               falls in the red portion of the meter scale,it is
       There are 3light-level range settingson the   advisableto reset the range and take another
        computer.The Hl (high)rangeis for high light    light reading.lf the meter pointer is in the red
         levels,commonly encounteredoutdoors; the    portion at the right side of the scale,move theI      MED (medium)rangeis for intermediatelight   Range Selector one range counterclockwise.lf
         levels,generallyfound indoors,while the LO    the pointer is at the left sideof the scale,move
         (low) rangeis for very low light levels.There is   one rangeclockwise,
       some overlapbetweenranges,but for optimum      It should be noted that resettingthe Range
        accuracyit is best to be on a rangewhere the   Selectorreleasesthe previousreading,and the
        meter pointer falls in the center of the meter   meter pointerwill drop to zero.(fnis is a feature
         scale.                                                designedto preventerroneousexposurereadings
                                              causedby changingrangeswithout takinga new       To set the range,place your thumb over the                                                                   light reading.)Always take a new light reoding        raisedRangeSelectorActuatorand push or pull                                                                     after changing ranges!         the raised actuator until the entire computer
        beginsto turn. (Do not changerangesby forcing                                                    1.3   MAKING INCIDENT-LIGHTREAD_        the Range IndicatorTabs!) Continue turning                                                                                                       I NGS          until the desiredRangeIndicatorTab (Hl, MED
         or LO) lines up directly opposite the Range    1.3.'l  When(andWhenNot) to Maketncident-
         IndicatorArrow at the bottom of the computer.   Light Readings
      Do not leavethe computerbetweenranges,as
        the meter will not operate unless the Range      f ncident-lightreadingsare made by measuring
         lndicatorArrow is directlyoppositeone of three   the light fallingon the subject.They are simple
       RangeIndicatorTabs!                      and quick to make,relativelyfoolproof, and are
                                                      the preferredmethodof determiningexposurein
         After makinga light reading,if the meter pointer   almostall conventionalphotographicsituations.




                                  r1(:r                                                                                                                        a  , * *           -  . -                                                     '            .  . r  ' *  ' k  ,  ,  :  ,
View original page 16
Page 17 · Read text
www.orphancameras.com

The key to the successof the incident-light
method is the largehemisphericalPhotosphere@,
which simulatesa three-dimensionalsubject.The
Photosphere" integrates"or averagesthe effect
of all of the different lightson the subject (see
illustration),and weighsthem proportionallyto
their effecton the exposure.
Certaiirsituationsin which incident-lightreadings
shouldnot be u seddirectly are:
  1 ) Whenthe subjectis inaccessible(ro that it
is physicallyimpossibleto hold the exposure
meter near the subject) and the lightingis non-
uniform (sothat the lightingon the subfectis not
the sameas the generalIighting).
  2) When the importantpart of the sceneto be
photographedis unusuallylight (suchas a snow-
coveredlandscape),or unusually dark (suchas a
blackcat).
The inaccessible-subjectsituationwould best be
handled by  reflected-lightmeasurement(see
Section1.4),whilethe lightldarksubjectsituation
would best be meteredby eitherthe reflectedor
the "incident-reflectedaverage" method (see
Sections1.4 and 1.5). The lightldark subject
View original page 17
Page 18 · Read text
www.orphancameras.com

 situation can also be read by  incident-light   meter parallelto the subjectwith the Photosphere
 measurement if  operator judgement is used;   pointing towards the camera.
 simply decreosethe meter-indicatedexposure by
 approximately 1/zof an f/stop for unusually 11g77                                                                                                              I N C ID E N T - L I G H TM E A S UR E M E N T
 subjects, or increose the exposure by approxi-
 matcly 1/'tstop for unusually dark subjects.For                                                                                                     'i"."':.:..EQUALILTUI\4INATION
 very light (or dark) subfects which do not include                                                            'i@ll' a significant amount of fleshtone, increase(or              ''i'i;"''.
 decrease)the exposureby  I full fi stop.
                                                                                                                                                                                        i
 Specific suggestionsfor handling specialsubjects                         I
 are given in Section4.3.                                 q
 1.3.2   lncident-lightMeasuringProcedure        I.qAr, t \          t
 I n c i d e n t - l i g hmt e a s u r e m c n t su,s i n g t h e C o m b i l l ,         CAli,ltRA             SUBIIOT
 are made as follows:                                           N O R M A L   L I G H T           U N E V E N L I G H T

       l ) S e t t h e F u n c t i o n S e l e c t o rS w i t c h ( o n t h e
b a c k o f  t h e m e t e r )r o r h e I N C I D E N T p o s i t i o n .
                                      NOTE:   lf necessarv,rotate the swivel head so
   2 ) H o l d  t h e m e t c r a r  t h e p r i n c i p a lp o i n t o f                        t h a t  t h e P h o t o s p h e r ew i l l n o t p i c k u p
interest of  the subject with  thc Photosphere          any  rcflections or shadows from  the
pointlng  directly  towords the camera (see illus-           photographer.(Seephoto on pageB).
tration at right). lf it is not possibleto get closeto
the  subject, but  the  lighting is uniform  (for       3) Prcss the On/Off butron and make the
e x a m p l e , o u t d o o r s u n d e r o p e n s k y ) , h o l d  t h e    reading(as indicatedin Section I .6).
View original page 18
Page 19 · Read text
www.orphancameras.com

 R O T A T E S W I V E L H E A D T O A V O I D R E F L E C T I O N S     thc light reflectedback from the subjecttowards
   O R S H A D O W S F R O M T H E P H O T O G R A P H E R        the camera.
                                           The  rcf lcctcd light method has the theoreticol
                                                 a d v a n t a g ct h a t i t i s p o s s i b l et o d e t e r m i n eo p t i m u m
                                            exposurcfor all given subjects,sincethe method
                                                                    is bascd on  the  iiglrt reflected from the actuol
                                                  subject. In the situation described in Section
                                                  1 . 3 . 1 , t l r e s n o w - c o v e r e lda n d s c a p ew o u l d r e f l e c t
                                                                                                   t n o r c   l i g h t a n d  t h e m e t e r w o u l d c a l l  f o r   l e s s
                                                       c x p o s u l - c t; l r c b l a c k c a t w o u l d  r e f l e c t l e s s l i g h t
                                                                                                  . r r r dt l r c r l c t o - w o L t l dc a l l f o l 'm o r e e x p o s u r e .

                                                Unfortunately, the theoreticaladvantageof the
                                                   reflectcd light method is often lost in practice
                                           becausc of  the need for the photographer to
                                                 decide whot portiott  of  the subject should be
                                           meusured. For example,  if  the photographer
                                                                                                                           i n c l u d e st o o m u c h b r i g h ts k y o r w h i t e b a c k g r o u n d
                                                                                                                           i n  h i s  r e f l e c t e d - l i g h mt e a s u r e m e n t ,t h e m e t e r
1.4   MAK ING REF LECTED.LIGHT READ-   reading will be too high and the forcground
                                                       s u bj c c t w i l l b c u n d e r e x p o s e di ;f h e  i n c l u d e st o t - rI NGS
                                      much shadow area in  the treasurement,the
1 .4.1  Wherr(andWhenNot) to MakeReflected-                                 m e t e r r c a di n g w i l l b e  t o o   l o w a n d  t h e p h o t o -
Light Readings                                            graph will be overexposed.Since successof the
Rcflected-liglrtreadingsarc madeby measuring  r e fl c c t e d - l i g h mt e t h o d i s h i g hl y d e p e n d e n tu p o n
View original page 19
Page 20 · Read text
www.orphancameras.com

the photographer'siudgementand carein making     2) From  the camera position, point  the
the measurement,it is generallyinferior to the   Reflected-Light Sensor towards the important
incidentlight methodwheneverthe photographer part of  the subject (see illustration below).
is in a rushto takea reading.
one specificsituationin which the conventional
reflected-lightreadingwill be erroneousis in
caseswhere the subject is small and is either
much lighter or darker than the background,
and it is not possibleto get closeenoughto the
subiectto takea small-areareflected-lightreading.
Unless the photographerhas the Spectra 1"
PhotoSpotaccessory,he is betteroff to makean
incident-lightreadingin this situation.

1.4.2   Reflected-LightMeasuringProcedure
Reflected-lightmeasurementscan be madeeither
by the simple "lorge-nreo"techniquedescribed                                      Remember that the Reflected-LlghtSensor seesbelow, or by the more advanced(and compli-                                                                                                  f ight over a 42" field, similar to your cameracated)  "small-areo" techn iques described i n                                           equipped with a normal lens; therefore if theSection 4.2.                                           scene is nonuniform, you should move in close
                                            enough  to  the  subject  to  exclude extraneousThe large-areameasuring procedu re is as fo Ilows:                                             background  (but  stay  far  enough away  to
  1) Set the FunctionSelectorSwitch (on the    include both  important  highlight and shadow
back of the meter)to the REFLECTEDposition.   areas). Be carefuI not  to cast any shadows or
View original page 20
Page 21 · Read text
www.orphancameras.com

    reflectionson the subiect.Also be carefulnot to       4) Set the distancescaleon the PhotoSpotto
    tip the Sensorupwards,as this may resultin in-   correspondto the approximatedistancebetween
   cludingtoo much brightsky in the reading(and   you and the subject.
   consequentialerroneousexposure).lf the subject
     is back-lit,eitherturn off the back-lightsor move
    close enough to the subject so that the meter      5) Standingat the cameraposition,point the
   doesnot measurethe backlights.               PhotoSpotlenstowardthe subject.Look through
                                                the PhotoSpot'sviewfinder and center the
      3) Pressthe On/Off button and make the     critical area (for example,the subject'sface)in
    reading,as indicatedin Section1 .6.               the 1" circlein the viewfinder:be certainto in-
                                              cludeboth highlightand shadowareas.
    1.4.3  Usingthe 1" PhotoSpotAccessory
   The 1' PhotoSpotaccessory(seeSection3.1) can      6) Pressthe On/Off button on the Combiand
   be usedfor exposuredeterminationby eitherthe   makethe reading,as indicatedin Section1.6.
    small-areareflected-lighttechniquesdescribedin
   Section4.2,or asfollows:
                                         NoTE:   It is possibleto switch back and forth
      1) Turn the swivelheadso that the Reflected-                                                 between normal (42") reflected-light
    LightSensoris on the samesideasthe computer.                                                    readingsand  1' PhotoSpotreadings.
      2) Removethe Photosphereby turning it 60"          Simplyset the FunctionSelectorswitch
   counterclockwiseand installthe 1' PhotoSpotin             to the REFLECTEDpositionwhenthe
      it's place (seeinstructionspackedin the Photo-            built-in (+Z') nettected-LightSensoris
                                                       pointedtowardsthe subject,and resetit   Spot carton).
                                                                to the ACCESSORYpositionwhen the
      3) Set the FunctionSelectorSwitch (on the          PhotoSpotaccessoryis pointedtowards
   backof the meter)to the ACCESSORYposition.          the subject.
1 0
View original page 21
Page 22 · Read text
www.orphancameras.com

CAUTION: Do not usethe AVERAGE position   The averagingfeature can be used anytime the
              of the Function SelectorSwitch   photographer can stand in a location where both
          when the PhotoSpotaccessoryis in    a valid incident-lightand a valid reflected-light
            place,as this will produceerroneous  measurement can  be  simultaneously made.
            readings.                           Generally, this would be somewherebetween the
                                          cameraposition and the subject.1.5   USINGTHE "INCIDENT-REFLECTED
AVERAGE"FEATURE''                                         It  can not  be used in cases of  non-uniform
                                                       lighting,where the light incident on the meter is
                                                   not the same as thatfalling on the subject. lt also
1.5.1  When (and When Not)  to Use the    can not be used when the critical portion of theAveragingFeature                                           sceneis very small and it is physicallyimpossible
                                                          to get close enough to the subject to measure
The SpectraCombi ll is equippedwith a unique   only  the  critical area. Finally, the  averaging
electro-opticalsystemthat enablesyou to take a    feature can not be used in coniunction with the "
singlereadingthat is the mathematicoloverageof     1" PhotoSpot accessory(sinceLhe photoSpot fits
the incident- and reflected-light reodings of the    over the incident-lightsensor).
scene. Since it measuresboth incident- and
reflected-light,it takesinto accountboth of the    '1.5.2                                                Procedure for  Making AVERAGEma.iorfactorsinfluencingphotographicexposure.                                       Measurements
The  lncident-ReflectedAveraging feature is   The incident-reflectedaveragingfeatureis used
particularly usefuI when the subject is either    to makemeasurementsasfollows:
unusuallylight or unusuallydark, such as the
"snow scene"or "black cat" photospreviously     1) Set the FunctionSelectorSwitch (on thedescribed.                                       backof rhe meter)to the AVERAGEposition.
                                                                                                                                                                          t 1
View original page 22
Page 23 · Read text
www.orphancameras.com

      2) Positionyourselfsomewherebetweenthe        3) Pressthe On/Off button and make the
   comeroposition ond the subiect (ut you wou ld   reading,as indicatedin Section1.6.
    for a reflected-lightreading), preferablyrelatively                                                                                                                    'l   cfoseto the subiect.Point the Photosphereback      .6   READINGTHE EXPOSURE
   towords the comerolensposition and the built-in                                                    After the meterhasbeenpositionedto makethe
    Reflected-Light Sensor towords the criticol zrect                                                          light reading,as describedin eitherSection1 .3,
    of the subject, being certain to include both    1.4 or 1.5, the exposurereadingis made as
   importanthighlightand shadowareaswithin the                                                  follows:
    42" measuringfield of the Reflected-LightSensor.
   (Becarefulnot to castany shadowsor reflections    1) Pressthe On/Off button and hold it until
   on the subiector on the Photosphere.)          the meterpointercomesto rest;then releasethe
                                              buttonslowly.
                                     NOTE:  lf the meterpointercomesto restin the
                                                       red portionat either end of the meter
                                                            scale,it is advisableto chongethe Ronge
                                                             Selector and repeat the light reoding. lf
                                                        the meter pointeris in the red portion
                                                                 at the right sideof the scale,move the
                                              RangeSelectorone rangecounterclock'
                                                         wise. lf the pointer is at the left sideof
                                                           the scale, move one range clockwise.
                                               Then repeatthe light reading.

                                                             2) Read the f/stop indicated by the position
                                                              of the meter pointer.

1 2
View original page 23
Page 24 · Read text
www.orphancameras.com

NOTE: View the meter from directly over the
        pointer to eliminate possiblereading
         error. The readingwill be correctwhen
        the meter pointer appearsstraight and
         of minimum thickness.

   3)  ff you would prefer to use a different
f/stop,simplyturn the outerdial of the computer
until the preferredflstop linesup with the meter
pointer.Note that this operationalsochangesthe
shutter speed! Read both the new f lstop and the
new shutter speed when you have fin ished
tu rning the outer d ial.





                                                                                               1 3
View original page 24
Page 26 · Read text
www.orphancameras.com

 2.O  M I S C E L L A NE O U SM E A S UR E M E NT S

 This section describesthc correct operatingproccdurefor making variousspecialmeasurements such
 a s l l l u m i n a n c e( f o o t - c a n d l oe r d e k a l u x ) ,L i g h t i n gC o n t r a s ta n d S u b j e c tC o n t r a s tm e a s u r e m e n t s .
 Other specialmeasurements,which requirevariousSpectraSystemAccessories,are outlined in Section3.

2.1   TLLUMTNANCE(FOOTCANDLEOR
D E K A L U X ) M E A S U R E M E N T S
llluminonce is the scicntific name for the measurc-
m e n t o f  i n c i d e n tl i g h t .T h e u n i t s o f m e a s u r e m e n t
f o r  i l l u m i n a n c ei s c o m m o n l y t h c " f o o t c a n d l e "i n
t h e U n i t e d S t a t e s ,a n d  t h e " l u x " o r  " d e k a l u x "
( l u x t i m e s 1 0 ) i n  i n t e r n a t i o n aul s e .
Your Spectra meter can be used to read directly
in foot-candles or  dekalux, according to  the
f o l l o w i n gp r o c c d u r e :
                @  1 ) R e m o v et h c P h o t o s p h e r e   ( h e m i s p h e r i c a l
w h i t e d i f f u s e r )b y g r i p p i n gt h e b l a c kk n u r l e dr i n g ,
pressinginwctrdsfirmly and turning it approxi-
mately 60" counterclockwise. (Store  it  in the
carrying caseor other protectedlocation.)Install
the Photodisk@(the flcttwhite diffuser)over rhe
I n c i d e n t S e n s o r , p r e s s i n g i n w a r d s f i r m l y a n d       2) Set the Function Selector Switch (on the
turning it clockwiseto secureit.                    b a c k o f  t h e m e t e r )t o  t h e I N C I D E N T p o s i t i o n .
View original page 26
Page 27 · Read text
www.orphancameras.com

      3) Preselectthe light-levelrange(Hl, MED or          b) Without changing the Film Speed
   LO) as follows:                                 setting,simply rotate the outer dial until the
                                              footcandlescalevalue indicatedbelow linesup   Hl   High light levels(40 to 50,000footcandles                                                 with silverreferencemark on the meterscale(see   or dekalux)                                            photo at left):
  MED  Mediumlevels(0.4 to 1 ,000footcandles
   or dekalux)                                   Light-Level       AIign FootcandleValue to
                                          Range       Reference Mark on Meter Scale  LO   Very low levels(0.004to 10 footcandles
   or dekalux)                            H I               100
                                  M E D                 1
      4\ Programthe computerto readllluminance                                      LO                  .01
   by eitherof the followingmethods:
         a) Set the Film Speeddial (asdescribedin   NOTE: Once set as indicated,the outer dial
   Section 1.1.1) to align the red "FC" (Foot-         shouldnot be moved until the illumi-
   Candle)mark with the FILM SPEEDpointer.        nancemeasurementis finished.
   Then rotate the outer dial of the computer
                                   '(    until the other red  FC" mark appearsin the     5) Hold the meter with the Photodiskin rhe
   CINE window.                             plane in which  it  is desiredto measure the
                                              illuminance.
                                                     6) Pressthe On/Off button and hold it unril
                                                the meter pointercomesto rest;then releasethe
     R E F E R E N C E                                buttonslowly.
    M A R K
                                        NOTE:   lf the meter pointer comesto rest in the
                                                             red portion at either end of the meter
'16
View original page 27
Page 29 · Read text
www.orphancameras.com

   2.2   LIGHTINGCONTRAST                   4) Point the Photodiskat the key lightsource
                                         and takea readingof the unshadedkey light.   LightingContrastis definedas the ratio of the
   illuminationproducedby the key light plusfill      5) Without disturbingthe computer,observe
    lightto that producedby the fill lightalone.       the positionof the meter pointeron the foot-
                                            candlescale.This valueis the key-to-fillratio of   Whilethe exactvalueof LightingContrastfor a                                                the lightingset-up.   particularsceneis a matterof artisticchoice,the
   following ronge of  values are commonlv   NOTE:  lf  it  is desiredto modify the lighting
   suggested:                                                ratio,changethe lightsand repeatSteps
                                                      2 through5. After the lightingratio has     C o l o rF i l m s :1 . 5 : 1t o 5 : 1
                                                beenoptimized,replacethe Photosphere
      Black& WhiteFilms: 2:1 to 16 1                                               and determinethe exposureby the
   LightingContrastis measuredasfollows:                  incident-lightmethod(seeSection1.1).
                                                2.3    SUB|ECT CONTRAST(BRTGHTNESS      1) Preparethe meterfor the measurementof                                       RATrO)   illuminanceas describedin Section2.1, Steps1
   through3.                                  Subject Contrast is different from Lighting
                                             Contrastin that it is a measurementof the light      2l Hold the meter in the subjectplane,with                                                          ratio reflectedfrom the actualsubject.   the Photodisk pointed towards the camera
   position.Use your hand to shadethe Photodisk   Subject Contrast, sometimescalled Brightness
   from the direct rays of the key light, and take a     Ratio, is definedas the ratio of the brightnessof
   readingof the fill light.                          the brightesthighlightto thar of the darkest
                                       shadowin which detailis desired.For optimum     3) Turn the outer dial of the computerso that                                             tone reproductionthis ratio should be on the   the 1 foot-candlemark is alienedwith the meter                                             orderof 4:1 to 32:1 for colorfilmsand32:1to   pointer.
                                             128:1for black-andwhite films.
1 B
View original page 29
Page 30 · Read text
www.orphancameras.com

Subject Contrast (or BrightnessRatio) is best     3) Turn the outer dial of the computerso that
measuredusingthe 1" PhotoSpotaccessory,since  the "1 foot-candle"mark is alienedwith the
the measuringfield is much smaller.lf  the   meterpointer.
PhotoSpotis not available,it will be necessaryto
movevery closeto the subject.                      4) Aim the meter or the PhotoSpotat the
                                                 highlight area of the subject and take a lightThe principlesof measurementare the samewith                                           readi ng.or without the 1" PhotoSpot.The procedureis as
follows:
                                                   5) Read the meter pointer position on the
   1)  lf  the PhotoSpotaccessoryis available, computer.This is a directreadingof the Subject
installit and set the FunctionSelectorSwitch  Contrastor BrightnessRatio.
(on the back of rhe merer)to RCCESSORy.lf
the PhotoSpotis not available,usethe Reflected-                                   NOTE:  lf  it  is necessaryto modify this ratio,Light Sensorand set the Function Selectorto                                            changethe lightingand repeatSteps2REFLECTED.
                                                through5 until the ratio is optimized.
  2) Aim the meter at the shadow areaof the        Then determinethe exposureby any of
subjectand take a light reading(asdescribedin           the methodsdescribedin Section1 .0 or
Section1.4).                                           4.2.





                                                                                               1 9
View original page 30
Page 32 · Read text
www.orphancameras.com

3.0   SPECTRA @ SYSTEM ACCESSORIES
A completeline of precision-madeaccessoriesareavailableto expandthe useof your Spectraexposure
meter.Theseincludethe following:
                       'M   1) Spectra1'PhotoSpot   (SpotmeterAttachment)
  2) SpectraFlexi-Probe'" (FlexibleFiberOpticsProbe)
  3) SpectraPhotoreaderrMProbe
                   rM (Enlargingand DensitometryAttachment)  4) SpectraSpot-Reader
  5) SpectraMicroscopeAdapter
Theseaccessoricsare bricfly describedon the following pages.Completeoperatinginstructionsare
packedwith the individualaccessory.





                                                                                                21
View original page 32
Page 33 · Read text
www.orphancameras.com

    3.'l   SPECTRA@1" PHOTOSPOT
  The Spectra 1" PhotoSpot is a unique optical accessorythat convertsyour exposuremeter into a
   high-sensitivity1" Spotmeterfor narrow-anglereflected-lightmeasurements.
  Use of the PhotoSpotwill enableyou to make accuratereflected-lightreadingsof distant sublects-
   particularlyusefulwith telephotolensesand for inaccessiblesubjectslike storewindows,theatrestages,
   animalsand wildlife. lt is also valuablefor photographingsmall subiectsin close-upphotography,for
  making accurateSubfectContrastor BrightnessRatio measurements,and for making "zone system"
  measurements.
                                             The PhotoSpot featuresa bright, wide-field,life-
                                                      size viewing system with a focusingeyepiece.A
                                                sharp reticle in the eyepieceaccuratelydefines
                                                     the 1' measuringfield. Parallaxcorrectionis pro-
                                                    vided for h ighest accuracy for all d istancesfrom
                                                     1 8    i n c h e s ( 0 . 5 m e t e r )  t o    i n f i n i t y . A  u n i q u e
                                                       electro-opticalsystem makes the exposuremeter
                                                    direct-readingwhen the PhotoSpotis in place.

                                                                                         r
                            lrno
                     soectroI
                                                                                                                                                       l o           I
                                  l- photospot


22
View original page 33

From the M. Butkus archive. Original publisher and archive notices are retained.
Check the model and edition against your equipment.

PDF verified 2026-10-10.