Home/Butkus archive/Taron
Film cameras

Taron III F/1.9 , single page User manual

User manual for Taron III F/1.9 , single page. 14 pages in English. Read the original PDF, download or print a copy without registration.

14 pagesEnglish6.2 MB PDF
Taron III F/1.9 , single page manual cover
Read the manual Original PDF
Download PDF
Loading your manual…Open PDF directly

Document details

Brand
Taron
Model / document
Taron III F/1.9 , single page
Document type
User manual
Language
English
Pages
14
File size
6.2 MB
Category
Film cameras
Document date
Not specified in catalog

Search available document text

Find a term, then jump to its page in the original PDF. Image-only pages may not be searchable; check the PDF for exact wording and diagrams.

Page 7 · Read text
Venmo @mike-butkus-camera  Ph. 2083
PayPal Name  Lynn@butkus.org      www.PayPal.me/lynnbutkus
View original page 7
Page 11 · Read text
"X" synchronfzation:

                                                                                    The X terminal
                                                                                                        is to be used
                                                                                                     with the elect-
                                                                                      ronic    flash
                                                                                                    units or class
                                                             F flash bulbs.
                                                                           For this pur.
                                                                                      pose, set the
                                                  MX lever at
                                                               X mark.
The distance betrveen the camera and the
objects can be automatically measured by use                               The  shutter
of the coupled range-finder.  Besides,   you                                              synchronizes at
will be aware of the fact  that a range of           all speeds up to 1/500 sec. with the electronic flash
sharpness is extending to the foreground as          units and also at l,/50 sec.or slower with the class
well as to the backsround of the subject.        F bulbs.
This area of sharpness is called the depth
of  field and all  objects  within  this  range        "M" synchronization:
will apper in acceptable sharpness.
                                                                           Set the MXThe depth of field is greater as the distance
to the objects is increased or the lens aper-                                                         lever at M mark
ture is reduced.                                                                                   and the shutter
                                                                                                   synchronizes at
Therefore, the depth of field relative to any                                                     all speeds up
given aperture can be easily obtained by                                                to 1,/500 sec.
reading the depth of field scale adj acent to                                             with the classthe distance scale,                                                          M flash bulbs.
When the lens is focused at the obj ect  of                                                                                    Remember that10 feet ahead of the camera with the F-stop
of  8, the scale will   tell you the depth of                                           the self-timer
field extends from 7  feet to 16 feet  ahead                                              cannot be usedof the camera.                                     when the MX lever is set at M.  Do not try  t-o move
                                                            the self-timer  lever in this  case as   it  makes the
On getting used to the camerh, you will  be         cause of trouble.
capable of  estimating the depth of     f ield
without  reading the scale.

                  r0                                                                  ll
View original page 11
Page 13 · Read text
The film exposed to the last must be rewound into
the original  cartridge from the take-up spool. The
Taron-35 Model  III  is  epuipped with an originally      When the entire roll of film has beendesigned rewinder which enables you to rewind the
film  rapidly and surely.                          exposed,  it  sometimes happens that
Pull out a small catch of  the rewinder  with  your       the winding lever will  not advance
finger  nail, and the crank shaft will  come out with        for a full stroke. Do not try to forcea pop as shown in the picture  "A"   Fold the shaft
on the foot and rotate    it   in  the  direction  of  an            it any further oS, by so doing, the
arrow as shown in "B'.   Remember to keep depres-.sing the rewinding button on the bottom of the camera        film  will  be  cut  off  from  t he
as shown in the next page until the film  is entirely        cartridge or you will make a cause
rewound into the cartridge.                        of troubles. When the lever stops
After      taking             out                 the                          push down                       cartridge,                                           the  re.        half-way, rewind the film   pushingwinding        crank                                  it             and                            will  be sheathed                                            clicking.
                                   down the rewiqding button.


                                                               ",'-. i'                 'r*   ;;, ' .-t:


              @





              @



                 t4                                            r5
View original page 13

From the M. Butkus archive. Original publisher and archive notices are retained.
Check the model and edition against your equipment.

PDF verified 2026-10-10.