Home/Butkus archive/Petri
Film cameras

Petri V6 User manual

User manual for Petri V6. 12 pages in English. Read the original PDF, download or print a copy without registration.

12 pagesEnglish1.6 MB PDF
Petri V6 manual cover
Read the manual Original PDF
Download PDF
Loading your manual…Open PDF directly

Document details

Brand
Petri
Model / document
Petri V6
Document type
User manual
Language
English
Pages
12
File size
1.6 MB
Category
Film cameras
Document date
Not specified in catalog

Search available document text

Find a term, then jump to its page in the original PDF. Image-only pages may not be searchable; check the PDF for exact wording and diagrams.

Page 2 · Read text
MAJOR SPECIFICATIONS OF PETRI FLEX V6

Type: Single Lens Reflex 35mm camera with fully automatic diaphragm and quick return mirror.

Film size: 35 mm film 120 or 36 exposures)

Picture size: 24mmX36mm

Standard Lens: " PETRI " 55 mm/f 1.8 ( or f 21 color corrected lens.

Speeds: B. 1/2, 1/4,1;8, 1/15, 1/30, X, 1/60,1/125 and 1/500 second. Single pivot non-rotating shutter dial

Viewfinder: Penta Prism viewfinder with built-in " Micromic-Lens Focusing".

Film transport: Rapid, single stroke (180°) lever transport which advances the film and winds the shutter
simultaneously.

Synchronization: FP, M and X automatic setting

Interchangeable Lens: Bayonet type Interchangeable Lenses can be attached to the camera

Others: Automatic Resetting Film Number Indicator with crank type film rewind system and built-in self timer

INDEX

MAJOR SPECIFICATIONS OF PETRI FLEX V6 2
DESCRIPTION OF PARTS , 4
FILM LOADING ..... ... .... .. ... ~ 6
VIEWFINDER AND FOCUSING 8
USING THE FULLY AUTOMATIC & MANUAL DIAPHRAGM OF THE LENS 9
USING THE SELFTIMER 10
FLASH PHOTOGRAPHY 10
HOW TO HOLD YOUR PETRI FLEX V6 CAMERA 11
FILM UNLOADING . . ... . . . ......................... 12
INTERCHANGING THE LENS 13
HOW TO USE THE PETRI CdS EXPOSURE METER 14
INFRA-RED PHOTOGRAPHY ............ 17
View original page 2
Page 4 · Read text
(20) Distance Scale

                                         (21) Depth of Field Indicator

                                         (22) Diaphragm Scale

                                         (23) AUTO & MANUAL Diaphragm Switch

                                         (24) Diaphragm Pin



FILM LOADING





Opening the Camera Back

Pull down the lever with your thumbnail to open the Camera Back. At the same time, the
Film Number Indicator automatically returns to zero.

Pulling out the Knob

Pull out the FILM REWIND KNOB on the top of camera. This is to allow the film
cassette to be put into the cassette chamber.


Slip the film end into any slit on the Take-up Spool and slide it down toward the bottom of the camera body and
check that the film perforation is properly engaged with the tooth of camera sprocket.

Advance the Film Advance Lever





Advance the Film Advance Lever a little to see if the film is fastened round the Take-up
Spool, before closing camera back.
View original page 4
Page 5 · Read text
www.butkus.us

Closing the Camera Back

The Camera Back will automatically be closed by light pressure.

Release Shutter Release Button and advance the Film Advance Lever.

Repeat this action twice, and you are ready to take your first picture.



VIEWFINDER AND FOCUSING


                                 The perfect combination of Fresnel Screen and
                                    Condenser Lens used in the viewing system of
                                      every Petri Flex V6 is the result of Petri's
                                        highly advanced technical and engineering
                                                ability. The precision focusing elements in the
                                     viewing system consist of a group of micro-
                                          lenses as shown in the center of the picture. As
                                  you look through the micro-lens area (A) in
                                          the viewfinder, you can see the subject clearly,
                        ONLY w'hen it is correctly focused.

                                       Rotating the focusing ring you will notice the
                                      appearance of something like a mesh of a net
                                           in the center of the viewfinder. This
                                             reticulation is caused by the flickering of
                                            reflected light entering the camera lens. When
                                          the subject is correctly focused the flickering
                                          grid fades away from the micro-lens area. In
                                          the second inner circle (B) the subject is
                                     always seen sharp and clear, even when the
                                          lens is out of focus. When the lens is correctly
                                      focused the image in the micro-lens area will
                                    be as sharp and clear as that seen in the
                                      surrounding circle (C).



USING THE FULLY AUTOMATIC & MANUAL DIAPHRAGM OF THE LENS





This shows: The mirror moving up, the diaphragm closing to the correct opening, the
film being exposed, the diaphragm opening fully for focusing and the mirror returning.
View original page 5
Page 6 · Read text
*Look at the AUTO & MANUAL Diaphragm
                                    Ring. Adjust the ring until the AUTO mark is on
                                     top of the lens barrel--the diaphragm is now set
                                         for FULLY AUTOMATIC operation. This is the
                                  normal position for most circumstances. When
                                you want to release the Automatic Diaphragm,
                                          slide the AUTO & MANUAL Switch in the
                                        direction indicated by the arrow on the ring.


* When the DIAPHRAGM is set on the AUTO position, it will only stop down to the set aperture, when the
shutter has been released. The AUTO position enables rapid accurate focusing as the subject in the viewfinder is
very bright and the DEPTH OF FIELD is extremely small. The MANUAL position has the advantage that you
can pre-view the DEPTH OF FIELD and see in the viewfinder the lens zone of sharpness with any aperture.


USING THE SELF TIMER


                       Adjust the Self timer Lever in the direction indicated by the
                      arrow in the illustration (180 degrees) Press the "Self. timer
                       Release Button" and the frame will be exposed after a delay of
                       approximately 11 seconds.

                     * Note that the Self timer can be set at in between position so
                         as to shorten the ret lease time.

                     * The Self timer can be set either or after advancing the film.


* All shutter speeds with the exception of the B setting can be used with Self timer.

* The main use of the Self timer is when the photographer wishes to join a group, which he is photographing. It
can also be useful for Microscopic photography or when using a long focus length. In all cases the use of tripod
is recommended.

FLASH PHOTOGRAPHY -





The shutter of the camera is synchronized for use with flash bulbs, which enables you to take photographs even
when the light is extremely poor. With reference to the picture (see next page) connect the synchronizing cable
of the flash gun to the flash socket on the camera. The flash gun can be attached to the PETR FLEX V6 by way
of the camera accessory shoe. When using F class, M class and FP class flash bulbs, or Electronic flash shutter
speeds must be selected according to the table shown below. (Speeds within the colored are available).
View original page 6
Page 8 · Read text
INTERCHANGING THE LENS


                            Adjust the Lens Mount Ring in an anti clockwise
                               direction until the red mark appears on top of the lens
                                 barrel. The Lens can then be removed from the camera.
                    When inserting the lens, line up the red dot on the camera
                        body with the red dot on the lens mount ring and when the
                              lens is in position firmly, turn the LENS MOUNT RING
                                in a clockwise direction. Before inserting the lens make
                             sure that the AUTO & MAN UAL control of the lens is
                         on the " MANUAL" position. A complete range of
                             interchangeable lenses from 35mm wide angle to 400 mm
                           Telephoto is available for your new Petri Flex V6 camera.



           A special adapter ring is available for using screw thread
                  interchangeable lenses.





PETRI LENS
The standard lens equipped with PETRI FLEX V6 camera is a high speed PETRI 55 mm four group · six
element using Lanthanum flint high refractive index glass. This PETRI LENS has a high resolving power even
at full aperture. It is equally suitable for black-and-white and color photography.


HOW TO USE THE PETRI CdS EXPOSURE METER


                                         Film Speed Indicator Shutter Speed
                                              Dial
                              ASA Exposure Multiples 6,10, 25, ·
                                                     (64), 100, 200, 400, 800, 1600; 3200
                                  DIN Exposure Multiples 9, 11, 15, ·
                                                     (16), 18, ~ (19), 21, 24, 27, 30, 33, 36

                                                Set the Film Speed Dial (ASA or
                                       DIN) to the corresponding number of
                                                  the film in use.

                                                 Slide the Exposure Meter into
                                                  position between the two-pin holders
                                                 located on the right hand side of the
                                          camera body while pressing the Meter
                                        Lock by thumb. The metal hooks of
                                                  the meter engage with the pins.
View original page 8
Page 9 · Read text
www.butkus.us



Replacing the Mercury Battery


                       Unscrew the metal cap, which is located at the bottom of
                             the Meter by turning in an anti-clockwise direction.
                         Replace with a new Mercury Battery and ensure that the
                             positive (+) is facing the, outside of the battery
                         compartment.

                          (webmaster: mercury batteries are not found in the U.S.
                         anymore.
                         See this link on a Wein Air replacement battery.


Mercury Battery suitable for use with this meter is:
Mallory PX-13
Mallory RM625
Eveready E625
National M -1D
Toshiba TH-MC
G.E. 625 (these days you need a Wein Air battery to replace any mercury battery, they only last several
months, but are pretty cheap)





                               Rotate the Shutter Speed Dial on the CdS Exposure
                            Meter to the right or left until a slight click is heard
                            which indicates that it has engaged with the Shutter
                             peed Dial of the camera.



                                Point the camera at the subject. Turn the "H-O-L"
                             Switch to the " H " position when using under normal
                                 daylight conditions. The " L" position is set when the
                                   lighting is poor.  (webmaster: The H - refers to High
                               Light Conditions, O for OFF and L for Low Light
                               Conditions)


Select the shutter speed, which is indicated by the red line on the left hand side of the meter. Read off the
aperture indicated by the red indicator needle by following the Guide Lines leading from the indicator needle to
the aperture scale. Transfer this aperture to the diaphragm of the camera lens.
In order to remove the meter, it must be remembered to press in the lock at the side of the meter.
In order to conserve the life of the Mercury Battery, turn the " H O-L" switch to the " O" position when the
meter is not in use.
View original page 9
Page 10 · Read text
DEPTH OF FIELD -




                              When the lens is
                                              correctly focused on
                                         a subject, you will
                                             notice that objects
                                              closer or farther
                                  away become less
                                             sharp, until they
                                   become almost
                                         completely blurred.
                                   However you will
                                         observe that there is
                                         a certain distance
                                      between the nearest
                                      and the farthest
                                  away subjects,
                                     which still appear
                                             sharp. This zone of
                                          sharpness is called
                                             the " DEPTH OF
                                    FIELD".




In order to check the depth of field with the exposure setting in use, observe the figures engraved on the Depth
of Field Indicator on the Lens. These figures are aperture values and are indicated by black lines spreading out
on either side of the red diamond mark at their center. The black lines point to the distance scale and indicate
the depth of field at different distances according to the aperture used. For example: When f/16 is selected and
the focusing distance is 6 feet, the depth of field is approximately 4.6 feet to 10 feet. See the illustration.

INFRARED PHOTOGRAPHY
When taking infra-red pictures, reset the focusing distance to the red line indicated by the aperture f 1.8 (or f2)
on the Depth of Field Scale.

PETRI FILTERS - FILTER FACTOR
* Filters reduce the amount of light entering the lens, and when using them it is therefore necessary to increase
the exposure. This increase is called the FILTER FACTOR. As shown in the table below, when the Y2 filter is
used, it is necessary to adjust the shutter speed from 1/500 second to 1/250 second, or f/8 to f/5.6.

* The " UV" filter does not have a filter factor and an increase in exposure is not necessary. This filter therefore
also serves a useful purpose in protecting the lens from dust and damage.
View original page 10
Page 11 · Read text
www.butkus.us

DIAPHRAGM ADJUSTMENT

Black & White                        Color

Y1   1/2 stop                  UV skylight  none

Y2   1 stops                  W4  1/2 stop

YA3 2 stops                      C4  1/2  stops

R1  2 stops                      C8  1  stops

POO 1 1/3 stops                     C12 1-1/3 stops

P01 2 stops                       85C 1/3 stops

                           NDX4  2 stops





PETRI INTERCHANGEABLE LENSES -

28mm f:3.5 Wide Angle Automatic diaphragm
35mm f :2.8 Wide Angle Automatic diaphragm
135mm f :3.5 Telephoto Automatic diaphragm
135mm f:2.8 Telephoto Pre-set diaphragm
200mm f :3.5 Telephoto Pre-set diaphragm
300mm f: 5.5 Telephoto Pre set diaphragm
400mm f:6.3 Telephoto Preset diaphragm
90mm - 190mm f :5.8 Zoom Lens
80mm - 200mm f:4.5 Zoom Lens
View original page 11

From the M. Butkus archive. Original publisher and archive notices are retained.
Check the model and edition against your equipment.

PDF verified 2026-10-10.