Home/Butkus archive/Mamiya
Film cameras

Mamiya Press Standard User manual

User manual for Mamiya Press Standard. 23 pages in English. Read the original PDF, download or print a copy without registration.

23 pagesEnglish2.8 MB PDF
Mamiya Press Standard manual cover
Read the manual Original PDF
Download PDF
Loading your manual…Open PDF directly

Document details

Brand
Mamiya
Model / document
Mamiya Press Standard
Document type
User manual
Language
English
Pages
23
File size
2.8 MB
Category
Film cameras
Document date
Not specified in catalog

Search available document text

Find a term, then jump to its page in the original PDF. Image-only pages may not be searchable; check the PDF for exact wording and diagrams.

Page 4 · Read text
www.orphancameras.com





GAMERABODY PARTS (B)      B 10 Flashgun Mount         LENS-SHUTTERASSEMBTY(R)
                             B 11  Tripod Socket
B  1  Lens Barrel Lock Button       B L2  Tripod Socket            R  1  Focusing Ring
B  2  Lens Coupling Mark          B 13  Strap Eyelets (2)          R  2  Depth of Field Scale
B  3  Viewfinder Window           B 14 Cable Release Holder       R  3  Distance Scale
B  4  Viewfinder Window Mask                                  R  4  Shutter Cocking Lever
      Lever (for 150mm lens)                                  R  5  Shutter Release Lever
B  5  Focusing Screen and Rollfilm      HAND GR|P (G)        R  6  Time Lever
      Holder Lock Knobs (2)                                   R  7  Shutterspeed Dial
B  6  Support Plate              G  1  Hand Grip               R  8  Aperture Control
B  7 Hand Grip Lock Ring        G  2  Shutter Release Button on   R  9 M-X Selector
B  8  Eyepiece                                the Hand Grip            R 10  Synchroflash Terminal
B  9  Accessory Clip            G  3  Cable Release            R 11 Cable Release Socket

                                                                                      - 2
View original page 4
Page 6 · Read text
www.orphancameras.com





       ROLLFTLMHOTDER (K)
K1   Filmwind Stop Release Lever
K2   Filmwind Knob
K3    Backlid Catch
K4    Safety Catch
K5    Insert Slide Cover
K6   Red Windor,v

                                                  3
View original page 6
Page 8 · Read text
www.orphancameras.com

  CHANGE OF NEGATIVE SIZE
  When  changing  picture  size  f rom 6 x 9 or 6 x: 7 to
 6 x 6 or 6 x 4.5 on  rollfilm,    it  is necessary to  fit the
 rollfilm  holder  with  the  appropriate  picture  mask.
When   taking   substandard    size   pictures,    the
exposures must be counted through  the red window
 at the back  of  the  rollfilm  holder.   The automatic
filmwind  stop and exposure  counter  cannot be used.
   Also  do not  fail  to  fit the appropriate  finder  win-
dow masks;  the viewfinder  masks coming  with  the
filmholder   in the case of the standard  lens   (f :90
mm),  the masks coming  with  the lens in the  case
of the long  focal  length  lens  (f -150 mm), and  the
separate viewfinder   for  mounting  on the  accessory
clip  in the case of the wide angle  lens (f :65 mm).

NAAMIYA PRESSINTERCHANGEABTEIENSES
  Standard  (F 3.5, f -90 mm), wide angle  (F 6.3, f -
65 mm),  and long focal  length  (F 5.6, f :150 mm)
lenses are easily and quickly  interchangeable,  and
each unit  couples  accurately  with  the  rangefinder.

                                                        5
View original page 8
Page 9 · Read text
The  MAMIYA-SEKOR   lenses  for  the MAMIYA        precision helicoid mount, with coupled rangefinder;
PRESS are specially designed anastigmats of high       or by means of the ground  glass  focusing  screen
resolving power  for needle-sharp reproductions on       available as an accessorv.
large  negative  areas.    Focusing   is  by  high

                                      Focal   lConstructionl             Picture Angles
                                          Length       |  (element-    I    n.,, q      6 x T      6 x 6     6 x 4 . 5                                                                         ( f -  m m ) i    g r o u p )
    Standard                           90         4-3       58"30'   51"50'     50"     420
    Long Focal Length                  150         4-3       37"10'    32030,     32"      26"
    trVideAngle                         65         4-4       75" 40'    67050'     63"     56010'

                                                       6
View original page 9
Page 14 · Read text
www.orphancameras.com

rnoved by  pressing  lens barrel  lock  button  (B  1)      marks, then  turn  the  barrel  clockwise  about 60 de-
toward  the lower  right  corner  of the camera body,       grees.    Slight   resistance   will  be  felt  before  the
as seen  from   the  froht,  and by  turning   the  lens-      catch holds and the  barrel  is locked  in  position.
shutter assembly counterclockwise  about 60 degrees,       When  changing   lenses, be sure  to  uncouple  re-
gripping  the barrel by means of the two  protrusions       lease cable (G 3) leading  from  grip  handle  (G 1).
provided  on the depth of field scale ring  (R2).  The        The  rangefinder  can be used, without  any  adjust-
assembly can be  lifted   out when  the  red  triangle       ment,  with  any  of the interchangeable  lenses.
mark  on  the  barrel   matches  the  red   dot  lens       CAUTION:    With   the  lens-shutter  assembly   re-
coupling  mark  (B 2) on the upper  left  hand corner      moved, the  interior  of the camera body  is exposed,
of  the camera  front.                                         revealing  a pin  protruding  from  above.     This  is
  To mount  lens on cam era, match the two coupling        the coupling  pin  for  the rangefinder.
                                                  Do not tamper  with  this  delicately  adjusted  part.
                                   SHUTTER (SEIKOSHA-S, ZERO S!ZE)
                                                   Shutterspeed Settings: B (bulb, manual operation),
                                                                                                          l, rlz, tl+, Lla, rl:.*,, Llso, rf ao, Lf:u:s,Lfz;0, and Lfsoo
                                                second
                                                     Aperture Settings (scale markings) :
                                                    Standard           3.5, 4, 5.6, 8, 11, 16, ZZ, gZ, 45
                                                 Long Focal Length 5.6, 8, 11, 16, 22, 32, 45
                                               Wide Angle        6.3, 8, 11, 16, 22, 32
                                                            Flash Synchronization; M and x synchroflash  settings.

                                                                                       - t t -
View original page 14
Page 16 · Read text
www.orphancameras.com

with  the ground  glass focusing  screen mounted on     FOCUSING METHODS
the back  of the camera or with a sports type frame
                                                     The  helicdid mounts of the lens-shutter assemblies
finder mounted on the accessory clip.  Reduction of
                                                                            pern'lit back and forth  movemerit  of the  lens barrel
subject size by means of the reverse telescope view-
                                                                             in  relation  to the camera  body, 3/8ilfor the standard
finder  is to 66 per cent of  life  size.  Correction  of
                                                               lens,77r" for  the long  focal length,  and3lta" for the
the viewfinder   field  for  various  negative  sizes is ef-
                                                        wide  angle.
fected  by use of masks over the viewfinder  window
                                                        Focus  adjusrment  may be effected  either  by the
(B 3).  When using  the wide angle  lens-shutter as-
                                                        coupled rangefinder, by tape measure or sight  judg-
sembly, a separate viewfinder  (reverse telescope type)
                                                    ment  and  distance  scale,  or by the ground  glass
is used mounted  on the accessory clip.   Viewfinder
                                                              focusing  screen.
correction  for  parallax   at close ranges   is  effected,
when using  standard  and long  focal  length  lenses,     SHUTTEROPERATION
by moving  the eyepiece (B 8).                                                       To cock shutter mechanism, push cocking  lever (R
 COUPTEDRANGEFINDER                            4) over toward  left  side of the camera (as seen from
  The  rangefinder   is combined  with  the  viewfinder,         rear).  The  shutter  is released as a general  rule by
and  is of the double image  focusing spot type.  The       the  left  index  finger through  the button  (G 2) and
length  of the triangulation  base is 60 mm, and the      cable release of the hand  grip.  However,   it  is also
magnification  is X 0.66.  Accurate  coupling  ranges       possible to trip the shutter  by means of the shutter
are:  for standard lens, 3.5 feet to oo;  f.rr long  focal      release lever (R5) operated by the right  index finger.
lengtir,  7 f.eet to oo ; and  for  wide  angle,  3.5 feet         For focusing  and  sighting  by means of the rear
to oo.                                                     focusing  screen, set shutterspeed  dial  (R 7)  at,,B",

                                                                                                                     | 3 -
View original page 16
Page 17 · Read text
cock  shutter,  and  pull  outward  the knob  of time       flange. Push into upper groove, the press down  firm'
lever (R 6).  Shutter  will  remain open.                          ly.  Lock  by turning  the lock knobs over 90 degrees.
 ROLLFILM HOLDERS                             The    f ocusing  screen  holder   is  secured  in  the
  Two types of  rollfilm  holders  for  the MAMIYA      same way.
PRESS are available : for 8 exposures of 6 x 9 cm ne-
gative size from a roll  of. I20 film, or for 10 exposures
of 6 x 7 cm negative  size. Both holders can be used
for  taking  pictures  of 6 x 6 cm  or 6 x 4.5 cm  size ;
holever  filmwind  stop and exposure counter cannot
be used in this case, the red window must be used
for  visual check of  film advance.
 OPERATION OF ROLLFILM HOLDER
  The  rollfilm  holder is secured to the camera back
mount by means of  trvo securing knobs (B 5).  To
remove  rollfilm   holder,  turn  knobs  (B 5) so  that
holding  flanges  are  turned  up  and  the   straight
edges are parallel  to the back mount, clear  of  the
 rollfrlm holder.  Lift up the lower side of the rollfilm
holder and pull  out  of top groove.  To attach  roll-
 film holder, reverse this procedure, making sure that
 the lock knobs (B 5) are turned  clear of the locking

                                                                                       - 1 4 -
View original page 17
Page 18 · Read text
www.orphancameras.com

 AUTOMATIC FILMWIND STOP                  wind  until  filmwind  knob  locks.   The  first frame
  By operating the filmwind  stop release lever (1),       of the rollfilm  is now in position for  picture-taking.
the filmwind  knob (2) can be freely  turned.   Turn       Attach   rollfilm   holder  to  camera,  then  pull  out
exposure  counter  indicates   the   triangle    start       slide cover.
position.   Open backlid  by pulling  curt both ends         Af ter  each  shot, operate  filmwind  stop  release
of the backlid catch (3).                                    lever  (1)  to permit  winding  and  transport  of  film
  Place unexposed film in film chamber.  Secure end       to next frame.  When removing  rollfilm holder from
of paper leader to empty  take-up spool. Commence     camera  with  unexposed  film  remaining   inside,
winding   carefully,  hold the  roll  of  film  tightly  as      always insert  sl ide cover  (5), then  push  in  saf ety
illustrated,  so  that  the  strip   is taken up  evenly.      catch  (4) so that  slide cover cannot be  pulled  out
When the start mark on the paper  leader  appears,      inadvertently  after rollfilm  holder has been removed.
align   it  with  the camera  start  mark  (7).    Close
backlid.  When  closing  backlid,  the pressure plate
may cause the  film and  camera  start marks  to go
out  of alignment.   This  is quite  in  order.
  When securing end of paper leader to slit of take-
up spool, exercise  the greatest care to effect a good
junction.     If  fitting   is poor, the take-up action  will
not be even and  straight,  causing  distortion  of the
film  surface.
  Operate filmwind  stop release lever (1) once, then

                                                                            - t 5 -
View original page 18
Page 19 · Read text
5x6 cm or 6x4.5 cm NEGATIVESIZE       When  using a tripod  for  vertical  pictures, remove
  Load  rollfilm  holder  with  film, with  filmwind  stop       the  grip  handle and replace  with  a tripod  adapter.
mechanism  ih  free  turning   position.   After  closing       A  cable release runs through  the grip handle. One
backlid,  open red window  cover  (6)  and turn  film'      end  of  the  cable is connected to the camera  shutter
wind  knob   (2)  until  numeral   1 appears   in  red         (at R  11), white  the  other  end  is attached  to the
window.                                                         shutter  button on the  grip  handle.  To keep  discon-
  When  taking  pictures  of 6 x 6 or 6 x 4.5 size, fit ap-      nected  cable  end. from  dangling   free,  attach  to
propriate  masks on  rollfilm  holder before  attaching       cable release holder  (B  14) on the  strap  eyelet.
to camera body.  Masks can be easily  fitted   if they
                                  MOUNTING FIASHGUN
are bent  slightly   lengthwise.
                                                 To  attach flashgun to the camera,  fix  flashgun
  After   first  exposure,  wind   film  while  watching
                                                  mounting piece on the flashgun mount (B 10) at the
red window   for  frame  number  to appear.
                                                                 right side (as seen from the rear).
  For  all  sizes other than the standard  6 x 9 cm, the
optical  viewfinder  window  must  be  corrected  by     CAMERA SUPPORT PLATE
means of  the corresPoding  mask.                   When the hinged support plate (B 6) attached to
                                                        the base of the camera is unfolded, a steady support
                                                                         is provided for the camera on any flat, level surface-
 GRIP HANDTE
  The  special  grip  handle  can be attached  to the     ACCESSORY CLIP                    ;
left  side of the camera (as seen from  the rear).  Lock'      A  standard accessory clip (B 9) is provided on
ing  is effected by screwing down the lock ring  (B 7).      top of the rangefinder casing.
View original page 19
Page 20 · Read text
www.orphancameras.com

     TRIPOD SOCKET                               capable of  taking,  with masks for  standard lens
      Two tripod socketsare provided, one (B 12) on     supplied,negativesof 6x6 and 6x4.5 size.
       the base of the camera for horizontal picture posi-       Focusing Screen Holder:  Assures sharpest possi-
        tion, and the other (B 11) on the flashgun mount,      ble image, critical composition.  Shows true area
F     for vertical position.                                  being  photographed, and  completely  eliminates
      DIMENSIONS AND WEIGHT                    problem of  parallax.  No need to remove holder
        6 sfrc' (height)  *9 z1sz"(width)  x  5zrfs2' (from       after  focusing  for  shot-making-just  insert plate
       front  of standard lens at oo in normal position to      or film pack holder.
       rear of rollfilm holder) ; approximately 4 z/16lbs.                                                                 Plate Holders: for dry  plates of ASA 6.5x 9 cm
                                                                     size, one plate per holder.
            ACCESSORIES                     Film Pack Holder:  for ASA 2y4x31/+' filmpack.
*       Lens Hoods:  Two  types  available,  one  for   the         Special Flashgun
       standard  lens,  the other  for  the long  focal  length        Flashgun Mounting Piece
        lens.  Wide  angle  lens requires  no lens hood.             Sports Finder:   available in two types; for 6 x 9
           Filters:   Available  in various types  in two  sizes,      or 6xT size.
         for  standard  and long  focal  length  lenses, and  for
                                                            Extension Rings:  for Close-Up Photography
      wide angle  lens.
                                                               Special MAMIYA PRESS Camying Bag           Rollfilm   llolders;   Available   in two  types;   for  8
      €xposures  of 6 x 9 cm  negatives  per  roll,  or  for  10        All-Metal Cable Release
      €xposures   of  6 x 7 cm  negatives.       Both  types        Tripod Adapter: for use of various types of tripods.

                                                                                                  - 1 7 -
View original page 20
Page 22 · Read text
www.orphancameras.com

         To   insert   plate  holder   or  film  pack  holder  in    PLATE HOLDER
        focusing  screen holder,   first press focusing  screen                                                                             Pull  out  backlid  catch  (1), the  backlid  can  be
        release lever  (P 4), keeping depressed  until  plate                                                        swung open by  applying  finger  pressqre to finger
         or  film pack holder  is  in  position.                                                                   hold  (2).
 .l
                                                              Working   in  complete  darkness,  place  plate  ino1   FILM PACK HOLDER                                   plate  holder,  emulsion   (dull)   side  dorvn,  facing
        Open  backlid  of  film  pack  holder  by  pressing      toward  slide cover  (3).   Close backlid and lock  ini{
       simultaneously  the two catch button  (1), and swing       position  by  means  of  backlid  catch  (1).   When
       open on hinge.  Take  fresh  film  pack, and load, tab       using  out  film   of the same size as the  plate,  use
       end  first and metal case side up,  in  the  film  pack      behind  the  cut  film  a discarded  plate,  or  a  clear
        holder.  Pull  tabs should protrude  beyond  the catch      piece  of  glass  of  the  right   size.   When  using
        buttons   (1).   Use  27/+ x 37/+o size film  pack  (I2       out  film  of  27/+ x 37/+o size,  first  insert  film  in
       exposures).                                              adapter frame and place frame  in plate holder.





                                                                                       -    | 9 -
View original page 22

From the M. Butkus archive. Original publisher and archive notices are retained.
Check the model and edition against your equipment.

PDF verified 2026-10-10.