Film cameras
METRAPHOT 2 IN User manual
User manual for METRAPHOT 2 IN. 11 pages in English. Read the original PDF, download or print a copy without registration.
11 pagesEnglish1.2 MB PDF

Loading your manual…Open PDF directly
Document details
- Brand
- Metraphot
- Model / document
- METRAPHOT 2 IN
- Document type
- User manual
- Language
- English
- Pages
- 11
- File size
- 1.2 MB
- Category
- Film cameras
- Document date
- Not specified in catalog
Search available document text
Find a term, then jump to its page in the original PDF. Image-only pages may not be searchable; check the PDF for exact wording and diagrams.
Page 3 · Read text
NOW! A PHOTOELECTRIC EXPOSURE
METER ONLY HALF AS LONG A9
YOUR THUMB!
. Here,. in one motchbox-smqll meter, ' ore the onswers to your exposure
problems by ei,ther incident or re- flected lig ht.
You con corry the tiny (l rlzxlrl4x5ll")
feother-light (to/e oz.) Meirophot 2 in^ a one of three conven ient woys :
o - otop your comero
,\\View original page 3Page 4 · Read text
www.butkus.us
b - honging from the neck strop c - in your hond
of comero or cose.
Whot's more, you con operote it with
one hond.
Corrying the Meler
Leove the meter right in the comero
occessory clip if you use the evereody
cose wh ich tokes both comero ond
www.butkus.us meter. lf not, you con get o speciol
leother meter cose thof hongs from ihe
neck strop of either the comero or its
cose, reody for instont use. Or, if youView original page 4Page 6 · Read text
www.butkus.us
window toword your subiect. The indi- Two Methods gf Reading
cotor needle of tlre meter will come Reflected Light
to rest in one of the series of block 1) Cqmero Position: You con get ex- ' cellent results by using your Model2ond white chonnels lusi in front of it.
When it does, rotote the shutter-speed right of comerq position. Just point
diol until the triongulor block pointer it"toword your subiect, but down
rests in the some relotive position, in slightly to ovoid including too.much
the sqme chonnel os lhe indicotor skylight if you oreworking outdoors
needle.
Once you hove done this, you will
find thot operiures ore lined up with -----t)oppropriote shutter speeds. Any of
the resuliing shutter-operture combi- -'--'notions will give you o correct ex- 'llposure. \\\\\\\
__.rf
Close-up: This is o very occurote
method. lt ist besi for controstY lighting ond for clo,r work. To useView original page 6Page 7 · Read text
it, go in close to your subiect. from its source, rother thon os it is
"Reod" the brightest ond dorkest reflected from your subiect. To do
ports of it.Then set triongulor block this, slip the smoll opol odopter
pointer to o spof in the chonnels (ottoched to the corrying choin)
thot is midwoy between the posi- into the slide fittings on either side
tions of the ind icotor need le crt of the honeycomb window. With
the brightest ond dorkest reodings.
3) Incident tight incident light odopter in ploce, ond stonding neor your subiect, point
Where contrqst between bockground the meier owoy from your subiect
ond- subiect is very greot, you-incidentmoy toword your comero ond toke the prefer to meosure the reoding, This will overoge the
rother thon the reflected light. Thot light from oll sources illuminoting
is, to meosure the light os lt comes your subiect.View original page 7Page 8 · Read text
www.butkus.us
NOTE: USE THE OPAL ADAPTER FOR 40 seconds. In LUX,|7,5(meter condles)INCIDENT LIGHT WORK ONLY, RE. the ronge is from to 21,600 LUX.
FLECTED LTGHT MEASUREMENTS TA- With the supersensitive element you
KEN WITH IT, OR INCIDENT LIGHT con meosure os little .os 1,75 LUX.
MEASUREMENTS TAKEN WITHOUT IT
WILL GIVE INCORRECT EXPOSURES.
Supersensitive Element
i For working in very weok light, you con get the supersensitive elemeni
mentioned obove. Just slip it into the
some sloiyou use for the incident light
odopter, REMEMBER TWO THINGS:
www.butkus.us
Meosuring Ronge
The Metrophot 2 hos on extremelY
wide meosuring ronge - l/'1000 sec. to
4 sec. bosed oh f/8 with o film roted
25 ASA. With on occessory supersen-
sitive element, the ronge extends toView original page 8Page 9 · Read text
l)When you use the supersensif'lve Zero Setting. lf the indicotor needle elemeni use the smoll rectongulor does not poinf to zero when the
pointer insteqd oi the triongle; honey-comb window is completely
2) All recrdings of the indicotor needle
beyond the middle of the scqle
with the block ond white chonnels
ore unusoble.
For incident light meosurements with
the supersensitive element ottoched
to the Metrophoi 2, o speciol odop-
ter is supplied. lt fits into the slide
fitting ot the window of the super-
sensitive element.
covered, you con eosily odiust itt
Just toke o smoll screwdriver qnd
turn the cou ntersu nk screw wh ich is
in the reqr of the meter housing
until the needle lines up properly.View original page 9Page 10 · Read text
www.butkus.us
Guorqnfee METRAPHOI 2I R
For Movie Comeros: When using theYour Metrophot 2 is guoronteed for MF 2 for movie comeros odiust film
6-two yeors. sensitivity os described on poge
Then selbct the desired oction volue
by meons of the triongulor Pointer
volue operture the correct reod[ight Volue Scole ond cer- con set o needle. Or You of the
Avoiloble on request for comeros with toin operture volue of the needle de-
shutters hoving light volue figures. flectioh ond reod the correcl oction
When using the light volue scole, the volue off the triongu lor Pointer.
iwo red rnorkings on the outer ond
inner odiustment ring should be olign-
ed. Now the light volue focing the Colibrotionchonnel ot which the exposure meter th-" When working for the f irst timeneedle points'shutter is reod off, ondcomero set for this volue. lf with colour film, especiolly rever-
should be noted thot in this cose the sible colour film with o very nor-
indicoted exposure time figures ore no row exposure r0nge, ir is recom-
longer of ony volue. mended' to gouge the film together with ihe comero ond the meter.
This is suitobly obtoined by moking
severol triol shots with the operture
volue reod off the meter, os well
os the next higher ond the nextView original page 10Page 11 · Read text
r
iIIlower volue. The best picture will ,
then provide the reference volues tfor the future os regords the setting
of the film sensitivity ot the ex-
posure meter, whereby the sensiti-
vity volue moy in some coses differ
from the volue printed on the
film's wropping. In cose picfures
with the next lower operture volue II8 hove come out much better thon ftthose with the indicoted operturevolue I I it will be necessory, in t
future, to set the volue lower by
113 DIN thon thot printed on the
film's wropping. Thus e. g. 12110
DIN only insteod of l5/.|0 DlN.
Corresponding ASA volues cqn be
reod off the meter, e. g. in this
porticu lor cose 20 ASA insteod of
r0 AsA.View original page 11From the M. Butkus archive. Original publisher and archive notices are retained.
Check the model and edition against your equipment.
PDF verified 2026-10-10.

