Film cameras
Vivitar XC-2 User manual
User manual for Vivitar XC-2. 39 pages in German, English. Read the original PDF, download or print a copy without registration.
39 pagesGerman, English4.2 MB PDF

Loading your manual…Open PDF directly
Document details
- Brand
- Vivitar
- Model / document
- Vivitar XC-2
- Document type
- User manual
- Language
- German, English
- Pages
- 39
- File size
- 4.2 MB
- Category
- Film cameras
- Document date
- Not specified in catalog
Search available document text
Find a term, then jump to its page in the original PDF. Image-only pages may not be searchable; check the PDF for exact wording and diagrams.
Page 2 · Read text
Digitally signed by Mike Butkus
DN: cn=Mike Butkus, o=Butkus camera manuals,
ou=butkus.org, email=mike@butkus.org, c=USMike Butkus Date: 2024.03.03 20:34:00 -05'00'View original page 2Page 4 · Read text
Bitte spenden Sie 2,50 Euro, um diese Website über E-Bay zu unterstützen ... www.PayPal.me/butkusView original page 4
Page 5 · Read text
Welcome to the new, compact world of Vivitar electronic
SLR photography! Your new Vivitar XC-2TM combines
the speed and precision ol sophisticated, integrated
microcircuitry with the smooth, rugged responsiveness
of uncompromising craftsmanship. T he V ivitar XC-2
is compact,lightweight, balanced and totally f unctional.
All controls are logically positioned tor quick adiustment.
The brilliant, LED viewtinder display provides an
immediate indication of exposure balance without
obstructing the viewtinder area. The twin'solenoid
sh utte r p rov i d es u n excel I ed accu r acy th ro ug hout
its entire range of 4 seconds to 1 /1000 second.
And the V ivitar XC-ATM Accessory converts your
camera to aperture-preterred automation in seconds!
XC-2TheVivitar to grow- awhensystems-designedyou are! SLR camerathat's ready
Description of Controls
Exposure Counter WindowQ
@ rilm Advance Lever
@ Shutter Release Button
@ fitm Rewind Button
@ nsnwindow
@ Snutter Speed Dial
@ Snutter Speed Index
@ notsnoe
@ fitm Plane Reference
@ veter switch / Spot or Average
@ ritm Rewind Knob
@ ritm Rewind Crank
@ nuto/vanualswitch
@ Aperture Ring
@ Aperture/Distance Scale Index LineView original page 5Page 6 · Read text
www.butkus.us @ Oeptfr of Field Scate @ Focusing Ring/Distance Scales @ Infrared Mark @ Sf,rtt", Release Lock @ TfrreaOeO Cable Release Socket @ s"tt-tir"r Lever @ Sett-timer LEo @ Oeptfr of Field Preview Release Button @ Strup Lugs & "D" Rings @ "R" outtet @ 'lX" Sync pC Ouilet @ ritm Chamber @ ritm Aperture @ Viewfinder @ SeriatNumber @ ritm Advance Sprocxers @ vutti-slotted rake-Up soool @ fitm pressure plate @ ritm Reminder Hotder @ ::::y compartment @ orruznsn conversion chart O ilrlio," Exposure@ tripoO Socket Control Lever Getting Acquainted with your New Before you shoot that first, important roll of film, read all of the following instructions on operating your camera. Fold out both sets of cover flaps for easy reference, and get acquainted with all controls and operating procedures. Tlke the time to practice focusing, shooting and programming -your Vivitar XC-2's control settings before y:ouView original page 6
Page 8 · Read text
www.butkus.us
actually load f ilm in the camera. The small amount of time
required for learning how to adjust and use your camera
witi be invaluable when you're ready to focus and shoot
"oncethat in a lifetime" photograph - you'll be ready it is!when
Battery Installation
The Vivitar XC-2's electronically controlled metering system
is powered by two, 1 .5 volt silver oxide batteries (Eveready
S-76, Mallory MS 76, G 13 or equivalent). To install the
batteries:
1 Unscrew the Battery Compartment Cover @ usinga coin.-
2 Insert the batteries with the POSITIVE (+ ) sides facingyou- (see photo "A").The inside of the Battery
Comoartment Cover is coded (+)as a reminder.
3 - Replace the Battery Compartment Cover.
Film Loading
1 Move Shutter Release Lock @ to the white "A"(Advance)- position.
2 Press Shutter Release Button @ to clear camera mechanism.-
3 Fold out and lift up on Film Rewind Crank @ to open the- camera back.
4 lnsert the f ilm cassette in the Film Chamber @, then
it slightly to push- down the Film Rewind Knob @ and turn
lock the cassette in Place.
5 Pull film leader across Film Aperture @ and insert end
of-leader into one of the slots in the f ilm Take-Up Spool I '
Advance Film Advance Lever @ slightly to secure film on
Take-Up Spool.
6 \ /ith the Film Rewind Crank in the folded out position, rewind- the f ilm slightly to remove any slack in the film
cassette. Recheck to see that the f ilm remains secured to
the Take-Up Spool and that it is properly aligned with theView original page 8Page 9 · Read text
Film Advance Sprockets g). Fold down rewind crank.
7 which indicates- closethatbackthecovercoveruntilis lockedyou hearin thean closedaudibleoosition.click,
Advance the film by alternately winding the Film Advance
Lever and pressing the Shutter Release Button until the
number "1 " appears in the Exposure Counter Window @.
As the Film Lever is wound, the Film Rewind Knob should
rotate, indicating that the f ilm is advancing properly.
Setting Film Speed
For properly exposed photog r"pnrffi
electronically controlled metering system must be set for
the correct ASA (USA) or DIN (lnternational) rating of the
film you are using. To set the film speeo:
@. 1 - Lift the collar on the Shutter Speed Dial
2 until the ASA rating for your film appears in -theTurnASAtheWindowcollar (Note: for DIN equivalents, refer to @
the DIN/ASA Conversion Chart Q9, located on the back of
your camera).
3 - Release the collar to lock the setting in place.
4 f ilm box in Film ReminderHolder- lnsert64 . tab from end of
Shutter Speed Selection
The Vivitar XC-2has a shutter speed range of 4 seconds to
1/1000 second, plus "8" (Bulb) for Time Exposures and a
"M" (Manual 1/50 second) setting, which can be usedin the event of-battery failure. To set the shutter speed, turn
the Shutter Speed Dial until the desired shutter speed
is aligned with the Shutter Speed Index O on the camera
body. When using shutter speeds below 1/30 of a second,
it is advisable to use a tripod and cable rerease to eliminate
the possibility of vibration due to camera movement. The
Vivitar XC-z is equipped with a Threaded Cabte Release
jor use with theseSocket @ and Tripod Socket (sd
accessories.View original page 9Page 10 · Read text
www.butkus.us
Time Exposures
When making time exposure photographs, your camera
should alwayl be tripod-mounted and used with a locking
cable release. The Vivitar XC's electronic shutter will
auto.matically control time exposures of up to 4 seconds.
For time exposures of over 4 seconds in duration:
1 Align "B" setting on Shutter Speed Dial with the
Shutter- Speed Index.
2 Advance f ilm and press in on tip of cable release to
open- the shutter. Turn cable release lock to hold shutter
open.
3 After the desired exposure time in seconds has
the shutter'elapsed,- release the cable release lock to close
Attaching Camera Carrying StraP
1 Slio the "clamp lock" latches over the ends of strapwith- the engraved Vivitar identif ication facing the ends'
Slip on plastic Protectors.
2 Feed ends of strap through camera "D" Rings
and- fold back in position, facing the camera body'
3- Feed the ends of strap up through the plastic protectors
and then through "clamp lock" latches until approximately
one inch (2.5 cm) extends beyond each latch.
4 Slip carrying strap over your head and readjust ends of-strap until the camera is suspended comfortably at
chest level.
Holding the Camera
Photos "B" and "c" illustrate the correct ways to hold the
camera for either horizontal or vertical format photographs.
Focusing the Camera
The Vivitar XC-2's focusing screen includes a central,
horizontal split-image rangefinder, which is surrounded
by a microprism collar (see photo "D"). To focus accurately:View original page 10Page 11 · Read text
1 maximum- Checkaperture.to see thatPressthe thelensDepthis fullyofopenedField previewto its
Release Button @ to assure that the lens was not stopped
down by previous actuation of the metering control system.
2 and- turnCenterthe theFocusingsplit-imageRing 19rangefuntiltheinder upperandon your keylowersubject
portions of your subject are one, clear vertical image.
3 f ragmented when image- Theis entirelymicroprismout ofcollarfocus,willb)a/appearappearshimmering but
viewable when image is nearly in focus and c) display a
sharp clear image of your subject when it is in focus.
It is especially useful when there are no pronounced vertical
subject elements on which to center the horizontal split-
image rangefinder.
4 and- compositionThe entire focusingof your screenphotograph.may beInasmuchused for asboththefocus
human eye tends to ignore minor differences in sharpness,
the horizontal split-image rangef inder and/or the
microprism collar should always be used for critical focus.
Setting the Lens Aperture
The standard lens supplied *itn yor@
automatic, allowing you to focus and compose at full
aperture for maximum viewfinder brightness. As the shutter
Release Button is pressed to make your exposure, the
lens automatically stops down to whatever f-stop you have
selected. In order to use this feature, the Auto/Manual
Switch @ must be in the upward "A" position, covering
the red "M" (Manual) marking
The Aperture Ring @ anO shutter controlthe amount of
light reaching the film during an exposure. At a given
shutter speed setting, turning the Aperture Ring from
the smallest number to the largest cuts the amount of
light at each marked f-stop by one-half .
The aperture setting also determines the near and far areas
in which items other than your key subject will remain
qView original page 11Page 12 · Read text
acceptably sharp. This "zone of focus" is www.butkus.usreferred to as Depth of Field Your lens features a Depth of Field Scale (@ , which allows you to select the zone of focus which will appear in the final photograph. Under normal lighting conditions, selecting a larger aperture opening (eg: f2.B orf4) will allow you to keep your key subject in sharp focus while eliminating distracting elements in the foreground or background of your photograph. Under the same conditions, selecting a smaller aperture opening (eg: f '1 1 or f 16) will allow you to maintain sharp focus on both near and distant objects. (See Photos "E" & "F"). Exposure Balance System Your Vivitar XC-2 incorporates an electronically controlled Exposure Balance System, which is automatically program- med when you set the ASA Dial for the proper rating of the film you are using. The electronic Exposure Balance System (null meter function) responds immediately and precisely to the slightest change in subject lighting or shutter speed/ aperture control settings Three LEDs (Light Emitting Diodes) are positioned above the viewf inder to display under, over or correct exposure conditions. Viewfinder Display The Exposure Balance System LED Display is positioned above the viewfinder, where it is readily visible (see photo "D"). To activate the Exposure Balance System LED Display: 1 - Wind the Film Advance Lever.2 Move the Shutter Release Lock Lever to the "A" posi -3- Depress Shutter Release Button halfway. ln addition to providing exposure information, the LED Display is programmed to function as a Battery Check. lf the LED Display does not illuminate, it indicates that a) the Shutter Speed Dial is at the mechanical "B' ' or "M" setting or b) there is insuff icient battery power remaining to actuate the electronic shutter mechanism (should this occur, the batteries should be replaced immediately). 6View original page 12
Page 13 · Read text
When the Exposure Balance System LED Display is acti-
vated, it will indicate one of the following conditions:
a/ Left (red)D LED indicates overexposure.
b/ Center (green) o LED indicates correct exposure.
LED indicates underexposure.c/ Right (red) €
d) lf Left and Right LEDs illuminate simultaneously, the
shutter speed/aperture combination is out of the exposure
system range. ITo set Exposure Balance System for a correct exposure:
1- Focus carefully on your subject.
2 - Depress the Shutter Release Button halfway.
a/ lf the left LED is illuminated, select a smaller aperture
opening and/or a faster shutter speed.
b/ lf the right LED is illuminated, select a larger aperture
opening and /or a slower shutter speed.
c/ lf Left and Right LEDs are simultaneously illuminated, the
shutter speed/aperture combination is out of the exposure
system range (see Exposure Value Chart, page 66).
www.butkus.us
Spot/Average Metering Systems
Your Vivitar XC-2 provides two separate through-the-lens
metering systems one for "Spot" readings and one for"Average" readings.-
"Spot" Readings
When the Meter Switch @ is moved to the red "Sp"
setting, the metering system will read approximately 10%
of the image seen in the viewfinder. The area covered is
approximated by the -l symbol below the microprism
collar.
The "Spot" metering system should be used for obtaining
correct exposures whenever your key subject is illuminated
differently than the surrounding area (e.9., shaded subjects
with strong backlighting or brightly lit subjects against a
dark background). Position your key subiect within the
7View original page 13Page 14 · Read text
microprism atea, focus, and adjust for correctwww.butkus.usexposure before composing your photograph. "Average" Readings When the Meter Switch @ is moved to the white "Av" setting, the metering sysiem reads the "Average" brightness of the entire image seen in the viewfinder' The "Average" metering system used when all elements of the scene being photographed are evenly illuminated. Multiple Exposure Control Your Vivitar xc-2 provides you with the creative option of making multiple exposures on a single frame of film' To use this option: 1 Wind the Film Advance Lever and make your firstexposure.- 2- Move the Multiple Exposure Control Lever @ in the direction of the white arrow until it stops, wind the Film Advance Lever to reset your shutter, and make your second exposure. The Multiple Exposure control Lever disengages the film advance mechanism, allowing you to reset your shutter and make multiple exposures without accidental film movement and loss of frame registration'View original page 14
Page 15 · Read text
Automatic Exposure Gontrol Your Vivitarxc-2 is designed for conversion to aperture- preferred automatic operation with the addition of the Vivitar xc-A'u Accessory. Requiring just seconds for attach- ment, the Vivitar XC-A couples direcily to the camera's Exposure Balance System. ln use, the lens is set at the desired aperture, the Film Advance Lever is wound, and the Exposure Balance System is activated by depressing the shutter Release Button halfway. operated by its own-, inde- pendent power supply (a single, 6-volt silver oxide battery), the Vivitar XC-A responds immediately to the Exposure Balance System's command signal by setting the correct shutter speed. As quickly as you can advance the film, focus and release the shutter, the Vivitar XC-A will continue to adjust and readjust for the correct Exposure Balance allyou need to do is focus and shoot! -View original page 15
Page 16 · Read text
www.butkus.us
Self Timer
The self-Timer Lever @ delays the tripping of the shutter
mechanism for approximately 10 seconds, allowing you to
include yourself in the photograph when desired' The
timed oetay f unction is fully electronic, with a self-Timer
LED @ displaying the lapsed time. The camera should be f irm support when thistriood-mounted or placed on a
feature is used. For Self-Timer release photographs:
1 Focus and compose photograph. Adjust controls for
(green LED)'correct- Exposure Baiance System Display
2 Push Self-Timer Lever all the way down' -3 Press Shutter Release Button. -4 Position yourself in photograph area within 10 seconds. - you decide not to use the self-Timer after setting NOTE:lf
it (see Step 2, above), move the Sh-utter Speed Dial to the ,,d" position. This will release the Self-Timer Lever without
activating the shutter mechanism.
Flash Photography
ffionized for "X" flash photography, "X" Sync PC Outlet @ ' using either the Hot Shoe @ or the
Withlither connection, the shutter should be set at the red,
1/60 second marking on the Shutter Speed Dia.l'
As described in "Auiomatic Exposure Control," your Vivitar
xc-zis designed for conversion to fully automatic.exposure
control under normal outdoor lighting conditions. when
photographing under lighting conditions that require the use
bt rrp"ptrrenlal, flash iilumination, use a Vivitar Automatic
Electronic Flash Unit for maximum speed, ease and con-
sistency of results.
Removing Film
f rame in. your film when you have finished exposing the last
cassetie (12,2}and 36-exposure settings are boded in red
on your Exposure Counter Dial), remove cassette:
trtn in Film Rewind Button @.
lo-View original page 16Page 17 · Read text
2- Fold out Film Rewind crank and turn in direction of arrow.
turns freery (without tension or 3 -"drag"),when Filmpull upRewindon Crankcrankto open camera back. The
Exposure Counter will automatically reset to zero.
lnsert fresh 4 - Removeroll of firmthewhireexposedcameracassetteback isforsiiilprocessing,open, oi ctose back for storage.
NOTE:lf camera is to be stored, press down on Shutter
Release Button to be certain that'camera mechanism is
cleared.
Helpful Hints
J. _ .llryrvr t.. "L" (locked) position when the Firm Advance1.u.r. hu, been
wound but you are.not yet ready to make your next exposure.
Accidentally pressing the shutter Rerease Button can'
a/ activate the Exposure Barance system, causing unnec-
essary battery drain or b) release the shutter mecEanism,
ruining a frame of film,
two 2 - smallThe customcompartmentscase forforyourstoringVivitara sparexc-2incorporatesset of batteries.
By always keeping fresh batteries i-n yow case, you will
avoid the inconvenience of losing electronic op'eration if the
camera's batteries should fail.
shourd be used whenever @you 3 - areTheloadingFilm Reminderor reloadingHorderfilm. By remembering to insert
the tab from the end of the firm box, you wiil arwayi h.u.
reminder as to the type of firm and number of e^posuies "
that are in your camera. when the camera is stored without
film in the Film chamber, remove the tab from the Firm
Reminder Holder to indicate that the camera is empty.
Caring for Your Gamera
1
this - Owner'sNEVEn rgp6Manual if any questions occur.
11View original page 17Page 18 · Read text
www.butkus.us
2 REMOVE BATTERIES WHEN STORING CAMERA. yourBatteries- can leak as they age, causing damagelo
ihe batteries for signs of leakage..r.r". Always inspect
before installing them in your camera'
g _ KEEP THE LENS CAP ON WHEN NOT TAKING
f rom dust orFHOrocnApHS. The cap protects your lens
dirt particles.
+-CLEANYoURLENSPRoPERLY'Removedustwithan
air blower. when necessary, use lens cleaner and tissue to
gentty clean the lens and viewfinder eyepiece'
5-CLEANYoURCAMERA'SINTERIoR.Periodica||y
f rom the f ilm chamber' i.tou" any dust or film particles
rear lens eiement, take-up spool areaor Film Pressure
Plate with an air blower. Inspect Film Pressure Plate for
accumulated deposits from film backing, and clean with
lens cleaner and tissue if required'
6-KEEPYOURCAMERAANDF|LMAWAYFRoMD|RECT
sut tLtcHT OR HEAT. Never store your camera or film on
the rear window deck, glove compartment or other hot areas
in your car.
7-PROTECTYOURcAMERAFROMMo|STURE.DoNoT
store your camera in a moisture-retaining enclosure or
environment. In areas of high humidity, extra care should be
taken to insure that your cahera is kept in a comparatively
cool, drY location.
8 DO NOT TOUCH SHUTTER CURTAIN. -
Specif ications
CameraType:35mmE|ectronicsLRwithspotoraveraging
TTL Exposure Balance SYstem.
Film Format:24mm x 36mm
Lens Mounf: Universal (M-42)Thread Mount
i c focal plane shutter' S h utter : Horizontal travel, f u I ly electron
Twinmatchedso|enoids;onepershutterb|ade.Elec-
tronic shutter speeds f rom 4 sec. to 1 /1000 sec', plus
mechanical "Bl'and "M" settings' Mechanical "M" set-View original page 18Page 19 · Read text
ting of 1/50 sec. provided when batteries are inoperative.
Multiple Exposure Provision: Multiple Exposure Control
Lever disengages film advance prior to shutter reset.
Selt-Timer; Approx. 10 second delay. Electronically timed
with LED display. Activated by Shutter Release Button.
Exposure Balance System: Three CdS cells behind mirror;
spot (1 0o/o) or averaging sensitivity pattern (switch
controlled). Match LED display in viewfinder, with LED
over and underexposure warnings.
Exposure Range: EV 0.5 to EV 18 (ASA 25lDtN 15 with
50mm f'l.7 lens)
Film Speed Range:ASA 25 to 3200, in 1 /3 EV increments.
Power Supply:Two, 1 .5 volt silver oxide batteries (Eveready
5-76, Mallory MS-76, G-13 or equivalent).
Viewfinder; Fixed eye-level pentaprism. Match LED display.
-1 .0 Diopter. Horizontal split image center with micro-
prism collar on matte fresnel screen.
Flash Contacts:"X" sync Hot Shoe and pC Ouilet contacts.
"X" sync up to 1/60 sec.
Film Advance; Single-stroke rapid Film Advance Lever.
Built-in double exposure prevention.
Exposure Counter:Progressive f rom "S" to 36. Automatic
Counter reset.
Film Loading: Vivitar Multi-Slotted Take-up Spool.
Film Rewind: Rewind Crank and Rewind Button on top of
camera.
Dimensions (body only):138.3 mm x 83.7 mm x 5.,| mm
5.4 in x 3.3 in x2.1 in
Weight (body only):530 g (18.6 oz)
Accessory Size:49 mm
Specif ications subject to change without notice.View original page 19Page 20 · Read text
www.butkus.usVivitarWillkommen in der neuen Welt der elektronischen
Ko m p akt- K I ei n b i t d -S pi eg e I ret I e xf otog r af i e ! I h re n e u e
VivitarXC-2'u Kamera verbindet die Schnelligkeit und
Prdzision von kunstvollen, integrierten elektronischen
M i k ro-S c h al tk re i se n m i t bed i ngungslos e r, ko m p ro'
mi Bl ose r, h andwer kt i ch e r F e rti gu ngstech ni k. Di e v ivitar
XC-2 Kamera ist kompakt, leicht, ausgewogen und
f unktionsgerechtf unktionell. AIte Kontrollelemente sind
ftir schnelte Bedienung positioniert. Der brillante Sucher
I e,m it LE D-Leu c htd i od e n - An zei g e ve r m ittelt sch n el
u nv e rzil g I i ch e An zei g e d e r B el i chtu ngsmessung,
ohne das Bildfeld des Suchers zu blockieren. Der
mit zwei elektronisch gesteuerten Magneten
i ch e f u n kti on i ere n d e V e rsch I u B g aranti e rt au Be rg ew iih nl
G e n au i g ke i t i n n e r h at b d es V e rsch I u Bzei te n be reiches
von 4 Sekunden bis 1 / 1000 Sekunde. Das Zubehdrsystem
Vivitar XC-A'" verwandelt lhre Kamera in eine
automatische Kamera mit Blendenvorwahl! Die
V ivitar XC-2 verk6rpert eine system-g erechte
Spieget retlex-Kamera, die entsprechend I hren W ilnschen
u nd Anf o rd e ru n gen au sbaut 5h i g ist !
Beschreibung der Kontrollen
O Bildzdhlwerk
@ Filmtransporthebel
@ Ausloser
@ Film-Ruckspul-Entriegelungsknopf
@ Anzeigefenster der ASA-Filmempfindlichkeit
O VerschluBzeitenknopf
@ VerschluBzeiten-lndex
@ Zubehorschuh mit Blitz-Mittenkontakt
O Markierung der Position der Filmebene
BelichtungsmeB-Sch alter /"Spot" bzw. M ittel@
O RuckspulknopfView original page 20Page 21 · Read text
@ nuctspulkurbel
@ Ruto/ Manuell-Einstellung
@ gtenOen-Einstellring
@ InOex fur Blenden- und Entfernungsskala
@ Scnarfentiefeskala
ng / EntfernungsskalaO f ntternungsri
@ Infrarot-Markierung
@ Ausloser-Verriegelung
@ Drahtausloser-AnschluB
@ setostausloser
@ SetOstausloser-LED-Anzeige (Leuchtdiode)
@ Scnarfentiefe-Kontrollknopf
@ Hrttaosen mit "D"-Ringen
@ "A"-AnschluB
@ gtitrkontakt fur X-Synchronisation
@ Film-Patronenkammer
@ Bildfenster
@ Sucner
@ Serien-Nummer
O Film-Transportzahnrdder
@ Mehrfach geschlitzte Aufwickelspule
@ Filmandruckplatte @ Deckel des@ Firm-Memo-Harter Batteriefaches
(p DIN/ASA-Umrechnungstabelle @ venrracn_
@ Stutiu-Gewinde Belichtungshebel
Machen Sie sich mit Ihrer Kamera vertraut
Bevor Sie lhren ersten, wichtigen Film verschieBen, sollten
Sie alle nachfolgenden Anweisungen der Kamera lesen.View original page 21Page 22 · Read text
www.butkus.usKlappen Sie beide Ausklappseiten des Umschlages aus und
machen Sie sich mit allen Kontroll- und Einstellelementen
vertraut. Nehmen Sie sich die Zeit und uben Sie die
Scharfeinstellung, das Auslosen und die Bedienung der
Vivitar XC-2-kontrolleinstellung, bevor Sie den ersten
Film in die Kamera einlegen. Der kurze Zeitaufwand fur
das Erlernen der Bedienung und des Einsatzes der Kamera
wird sich dadurch bezahlt machen, daB Sie jederzeit
einstell- und auslosebereit sind fur einen schnellen
SchnappschuB!
Das Einsetzen der Batterien
Das elektron i sch gesteuerte Bel ichtungsmeB-System der
Vivitar XC-2 Kamera wird durch zwei 1,5 Volt Silberoxyd-
batterien gespeist (Eveready 5-76, Mallory MS 76, G 13 oder
gleichwertige). Und so erfolgt der Einbau der Batterien:
1 - offnen Sie den Deckel des Batteriefaches @ mit einerMrlnze.
2 Legen Sie die Batterien mit dem PLUSPOL (* ) nachoben- ein (siehe Abbildung "A"). Die innere Seite des
Batteriefach-Deckels ist mit einer (*)-Markierung
gekennzeichnet,
3 - SchlieBen Sie den Deckel des Batteriefaches.
Das Einlegen des Films
"A"1 - - Drehen(Vorwdrts)Sie- diePosition.Ausloser-Verriegelung @ in die weiBe
@ .2 - Losen Sie aus3- Klappen Sie die Ruckspulkurbel @ heraus und ziehen
Sie diese hoch, um die Kamera-Ruckwand zu offnen.
4- Legen Sie.die Filmpatrone in die Film-Patronenkammer
@, drucken Sie dann den Ruckspulknopf @ hinein und
drehen Sie ihn vorsichtig, um die Filmpatrone in ihrer Lage
zu befestigen.
hinweg5 - Ziehenund steckenSie den SieFilmdnfangden Filmanfanguber dasinBildfenstereinen der @View original page 22Page 23 · Read text
Schlitze der Aufwickelspule @ . Betritigen Sie nun den Filmtransporthebel @ vorsichtig, um dem Filmanfang in der Aufwickelspule Halt zu geben. 6 klappten- DrehenPositionSie nunlangsamdie Ruckspulkurbelzurrick, um denin eingelegtender ausge- Film in seiner Lage zu spannen. Prufen Sie nochmals, ob der Film in der Aufwickelspule richtig sitzt, und ob der Film einwandfrei in die Film-Transportzahnrdder @ greift. Falten Sie die Ruckspulkurbel nieder. 7 Betdtigen- schlieBenSie nunsiedendie FilmtransporthebelRrlckwand, daB sie beideuilich einrastet. niedergedrricktem Ausl6ser so lange, bis im Fenster des Bildzdhlwerks O die Nummer "1" erscheint. Bei Betdtigung des Film-Transporthebels soll sich der Ruckspulknopf drehen: dadurch erkennen Sie. ob der Film korrekt transportiert wird. Das Einstellen der Filmempfindlichkeit Frir richtig belichtete Aufnahmen muB dem elektronisch gesteuerten BelichtungsmeB-System lhrer Vivitar XC-2 Kamera die richtige DIN- oder ASA-Empfindlichkeit je nach verwendetem Film eingegeben werden. Und- so erfolgt die Ei nstel I ung der- Fi lmempfind lichkeit: 1 - an.Heben Sie den Ring am VerschluBzeiten @ 2 entsprechende- Drehen SieASA-Wertden Ring soim lange,ASA-Einstellfensterbis der lhrem Film@ erscheint (zur Beachtung: entsprechende DIN-Werte konnen Sie auf der DIN/ASA-Umrechnungstabelle @ an der Ruckseite der Kamera ermitteln). 3 - Arretieren Sie den Ring in seiner Lage. 4 Sie- dieseReiBenLascheSie diein denLascheFilm-Memo-Halterder Filmpackung@.ab und stecken Die Einstellun der VerschluBzeit Die Vivitar XC-2Kamera verfrigt uber VerschluBzeiten von IView original page 23
From the M. Butkus archive. Original publisher and archive notices are retained.
Check the model and edition against your equipment.
PDF verified 2026-10-10.
